Literature DB >> 19132755

Eddy-current compensated diffusion weighting with a single refocusing RF pulse.

Jürgen Finsterbusch1.   

Abstract

A modification of the Stejskal-Tanner diffusion-weighting preparation with a single refocusing RF pulse is presented which involves three gradient lobes that can be adjusted to null eddy currents with any given decay rate to reduce geometric distortions in diffusion-weighted echo-planar imaging (EPI). It has a very similar compensation performance as the commonly used double-spin-echo preparation but (i) is less sensitive to flip angle imperfections, e.g. along the slice profile, and B(1) inhomogeneities and (ii) can yield shorter echo times for moderate b values, notably for longer echo trains as required for higher spatial resolution. It therefore can provide an increased signal-to-noise ratio as is simulated numerically and demonstrated experimentally in water phantoms and the human brain for standard EPI (2.0 x 2.0 mm(2)) and high-resolution EPI of inner field-of-views using 2D-selective RF excitations (0.5 x 1.0 mm(2)). Thus, the presented preparation may help to overcome current limitations of diffusion-weighted EPI, in particular at high static magnetic fields.

Entities:  

Mesh:

Year:  2009        PMID: 19132755     DOI: 10.1002/mrm.21899

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences.

Authors:  Stavroula Kyriazi; Matthew Blackledge; David J Collins; Nandita M Desouza
Journal:  Eur Radiol       Date:  2010-06-10       Impact factor: 5.315

2.  High spatial and angular resolution diffusion-weighted imaging reveals forniceal damage related to memory impairment.

Authors:  Katherine A Koenig; Ken E Sakaie; Mark J Lowe; Jian Lin; Lael Stone; Robert A Bermel; Erik B Beall; Stephen M Rao; Bruce D Trapp; Micheal D Phillips
Journal:  Magn Reson Imaging       Date:  2013-01-05       Impact factor: 2.546

3.  MR with surface coils in the follow-up after endoscopic laser resection for glottic squamous cell carcinoma: feasibility and diagnostic accuracy.

Authors:  Marco Ravanelli; Davide Farina; Paola Rizzardi; Elisa Botturi; Paola Prandolini; Stefano Mangili; Giorgio Peretti; Piero Nicolai; Roberto Maroldi
Journal:  Neuroradiology       Date:  2012-12-22       Impact factor: 2.804

4.  Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time.

Authors:  Manoj Shrestha; Pavel Hok; Ulrike Nöth; Bianca Lienerth; Ralf Deichmann
Journal:  MAGMA       Date:  2018-03-30       Impact factor: 2.310

5.  Quantification and compensation of eddy-current-induced magnetic-field gradients.

Authors:  William M Spees; Niels Buhl; Peng Sun; Joseph J H Ackerman; Jeffrey J Neil; Joel R Garbow
Journal:  J Magn Reson       Date:  2011-06-25       Impact factor: 2.229

6.  Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding.

Authors:  Dimitrios C Karampinos; Suchandrima Banerjee; Kevin F King; Thomas M Link; Sharmila Majumdar
Journal:  NMR Biomed       Date:  2011-11-11       Impact factor: 4.044

Review 7.  Tractography methods and findings in brain tumors and traumatic brain injury.

Authors:  Fang-Cheng Yeh; Andrei Irimia; Dhiego Chaves de Almeida Bastos; Alexandra J Golby
Journal:  Neuroimage       Date:  2021-10-18       Impact factor: 6.556

8.  Comparison of twice refocused spin echo versus stimulated echo diffusion tensor imaging for tracking muscle fibers.

Authors:  Brian Noehren; Anders Andersen; Thorsten Feiweier; Bruce Damon; Peter Hardy
Journal:  J Magn Reson Imaging       Date:  2014-02-19       Impact factor: 4.813

9.  Eddy current nulled constrained optimization of isotropic diffusion encoding gradient waveforms.

Authors:  Grant Yang; Jennifer A McNab
Journal:  Magn Reson Med       Date:  2018-10-10       Impact factor: 4.668

10.  The impact of post-processing on spinal cord diffusion tensor imaging.

Authors:  Siawoosh Mohammadi; Patrick Freund; Thorsten Feiweier; Armin Curt; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2013-01-05       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.