Literature DB >> 19126492

20 MHz/40 MHz dual element transducers for high frequency harmonic imaging.

Hyung Ham Kim1, Jonathan M Cannata, Ruibin Liu, Jin Ho Chang, Ronald H Silverman, K Kirk Shung.   

Abstract

Concentric annular type dual element transducers for second harmonic imaging at 20 MHz / 40 MHz were designed and fabricated to improve spatial resolution and depth of penetration for ophthalmic imaging applications. The outer ring element was designed to transmit the 20 MHz signal and the inner circular element was designed to receive the 40 MHz second harmonic signal. Lithium niobate (LiNbO(3)), with its low dielectric constant, was used as the piezoelectric material to achieve good electrical impedance matching. Double matching layers and conductive backing were used and optimized by KLM modeling to achieve high sensitivity and wide bandwidth for harmonic imaging and superior time-domain characteristics. Prototype transducers were fabricated and evaluated quantitatively and clinically. The average measured center frequency for the transmit ring element was 21 MHz and the one-way --3 dB bandwidth was greater than 50%. The 40 MHz receive element functioned at 31 MHz center frequency with acceptable bandwidth to receive attenuated and frequency downshifted harmonic signal. The lateral beam profile for the 20 MHz ring elements at the focus matched the Field II simulated results well, and the effect of outer ring diameter was also examined. Images of a posterior segment of an excised pig eye and a choroidal nevus of human eye were obtained both for single element and dual element transducers and compared to demonstrate the advantages of dual element harmonic imaging.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19126492      PMCID: PMC2717901          DOI: 10.1109/TUFFC.2008.983

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  9 in total

Review 1.  Nonlinear acoustics in diagnostic ultrasound.

Authors:  Francis A Duck
Journal:  Ultrasound Med Biol       Date:  2002-01       Impact factor: 2.998

2.  High-resolution ultrasonic imaging of the posterior segment.

Authors:  D Jackson Coleman; Ronald H Silverman; Almira Chabi; Mark J Rondeau; K Kirk Shung; Jon Cannata; Harvey Lincoff
Journal:  Ophthalmology       Date:  2004-07       Impact factor: 12.079

3.  Schlieren metrology for high frequency medical ultrasound.

Authors:  Claudio I Zanelli; Samuel M Howard
Journal:  Ultrasonics       Date:  2006-08-08       Impact factor: 2.890

4.  Design of a multilayer transducer for acoustic bladder volume assessment.

Authors:  Egon J W Merks; Ayache Bouakaz; Nicolaas Bom; Charles T Lancée; Antonius F W van der Steen; Nico de Jong
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-10       Impact factor: 2.725

5.  High-frequency harmonic imaging of the eye.

Authors:  Ronald H Silverman; D Jackson Coleman; Jeffrey A Ketterling; Frederic L Lizzi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

6.  Transducer for harmonic intravascular ultrasound imaging.

Authors:  Hendrik J Vos; Martijn E Frijlink; Erik Droog; David E Goertz; Gerrit Blacquière; Anton Gisolf; Nico de Jong; Antonius F W van der Steen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

7.  An ultrasonic transducer for second harmonic imaging using a LiNbO3 plate with a local ferroelectric inversion layer.

Authors:  Kiyoshi Nakamura; Kentaro Fukazawa; Ken Yamada; Shigemi Saito
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-03       Impact factor: 2.725

8.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

9.  Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis.

Authors:  D Z Reinstein; R H Silverman; T Raevsky; G J Simoni; H O Lloyd; D J Najafi; M J Rondeau; D J Coleman
Journal:  J Refract Surg       Date:  2000 Jul-Aug       Impact factor: 3.573

  9 in total
  6 in total

1.  Monitoring tissue inflammation and responses to drug treatments in early stages of mice bone fracture using 50 MHz ultrasound.

Authors:  Yen-Chu Chen; Yi-Hsun Lin; Shyh-Hau Wang; Shih-Ping Lin; K Kirk Shung; Chia-Ching Wu
Journal:  Ultrasonics       Date:  2013-07-11       Impact factor: 2.890

Review 2.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

3.  Frequency compounded imaging with a high-frequency dual element transducer.

Authors:  Jin Ho Chang; Hyung Ham Kim; Jungwoo Lee; K Kirk Shung
Journal:  Ultrasonics       Date:  2009-10-24       Impact factor: 2.890

4.  Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Mike Lee; Sibo Li; F Stuart Foster; Xiaoning Jiang; Paul A Dayton
Journal:  Sensors (Basel)       Date:  2014-11-04       Impact factor: 3.576

5.  Sequential inflammation model for Achilles tendinopathy by elastin degradation with treadmill exercise.

Authors:  Yi-Ting Wu; Yen-Ting Wu; Tzu-Chieh Huang; Fong-Chin Su; I-Ming Jou; Chia-Ching Wu
Journal:  J Orthop Translat       Date:  2020-04-02       Impact factor: 5.191

6.  Cross-Sectional Nakagami Images in Passive Stretches Reveal Damage of Injured Muscles.

Authors:  Shih-Ping Lin; Yi-Hsun Lin; Shih-Chen Fan; Bu-Miin Huang; Wei-Yin Lin; Shyh-Hau Wang; K Kirk Shung; Fong-Chin Su; Chia-Ching Wu
Journal:  Biomed Res Int       Date:  2016-01-05       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.