Literature DB >> 19123884

Image registration accuracy of GammaPlan: a phantom study.

Yoichi Watanabe1, Eunyoung Han.   

Abstract

OBJECT: The authors evaluated the accuracy of the automatic image coregistration function implemented in the Leksell GammaPlan treatment planning software (Version 4C with MultiView Extension and Version 8.0).
METHODS: The authors used a phantom with 9 landmarks (tips of thin cylindrical acrylic rods) evenly distributed in the treatment space. Two sets of images of the phantom were taken with both CT and MR imaging systems. The first image was obtained with the phantom aligned with the scanner's axis and the second scan was made by intentionally shifting and rotating the phantom relative to the scanner's axis. The authors attempted image registration of 2 CT image sets, CT and MR image sets, and 2 MR image sets. The accuracy of image registration was evaluated by measuring the x, y, and z coordinate values of the landmarks on each image set after 2 image sets were coregistered. The authors calculated the differences of the x, y, and z values and the distance, d, between corresponding landmarks in 2 image sets. To minimize interobserver dependence of coordinate measurements, 2 physicists did measurements independently.
RESULTS: The distances, d, averaged over the 9 landmarks, were 2.63 +/- 1.64 and 0.95 +/- 0.25 mm for CT-CT and MR-MR image registrations, respectively. When the CT images of the air-filled phantom and MR images were coregistered, however, the algorithm performed poorly: d = 13.8 +/- 1.23 mm. To remedy this, the authors undertook a 2-step process by first performing landmark-based registration of the 2 image sets and subsequently applying the automatic registration. With this approach, the mean distance drastically improved: d = 0.74 +/- 0.31 mm. When the water-filled phantom was used for CT scans, the registration accuracy of CT and MR image sets was acceptable without the 2-step registration process: d = 1.18 +/- 0.36 mm.
CONCLUSIONS: The accuracy of automatic registration of image sets from the same modality was within the voxel size of the scanned images. The accuracy of CT-MR image registration strongly depended on whether the phantom for CT scans was filled with air or water. This indicates the significant effect of the amount of common data available for a mutual information-based algorithm on the accuracy.

Entities:  

Mesh:

Year:  2008        PMID: 19123884     DOI: 10.3171/JNS/2008/109/12/S5

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  Image-based biophysical modeling predicts cortical potentials evoked with subthalamic deep brain stimulation.

Authors:  Bryan Howell; Faical Isbaine; Jon T Willie; Enrico Opri; Robert E Gross; Coralie De Hemptinne; Philip A Starr; Cameron C McIntyre; Svjetlana Miocinovic
Journal:  Brain Stimul       Date:  2021-03-20       Impact factor: 8.955

2.  Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery.

Authors:  Hisato Nakazawa; Yoshimasa Mori; Masataka Komori; Yuta Shibamoto; Takahiko Tsugawa; Tatsuya Kobayashi; Chisa Hashizume
Journal:  J Radiat Res       Date:  2014-04-29       Impact factor: 2.724

3.  Assessment of image co-registration accuracy for frameless gamma knife surgery.

Authors:  Hyun-Tai Chung; Jeong Hun Kim; Jin Wook Kim; Sun Ha Paek; Dong Gyu Kim; Kook Jin Chun; Tae Hoon Kim; Yong Kyun Kim
Journal:  PLoS One       Date:  2018-03-02       Impact factor: 3.240

4.  Image fusion pitfalls for cranial radiosurgery.

Authors:  Benjamin P Jonker
Journal:  Surg Neurol Int       Date:  2013-04-17

5.  Gamma Knife® icon CBCT offers improved localization workflow for frame-based treatment.

Authors:  William N Duggar; Bart Morris; Ali Fatemi; Jemeria Bonds; Rui He; Madhava Kanakamedala; Roberto Rey-Dios; Srinivasan Vijayakumar; Claus Yang
Journal:  J Appl Clin Med Phys       Date:  2019-10-06       Impact factor: 2.102

6.  Utilization of CBCT to improve the delivery accuracy of Gamma Knife radiosurgery with G-frame.

Authors:  Lindsey Claps; Damien Mathew; Kathryn Dusenbery; Margaret Reynolds; Yoichi Watanabe
Journal:  J Appl Clin Med Phys       Date:  2021-06-30       Impact factor: 2.102

  6 in total