Literature DB >> 19122074

Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty.

Young-Hoo Kim1, Jun-Shik Kim, Yoowang Choi, Oh-Ryong Kwon.   

Abstract

BACKGROUND: Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee arthroplasty with regard to the precision of implant positioning.
METHODS: Sequential simultaneous bilateral total knee arthroplasties were carried out in 160 patients (320 knees). One knee was replaced with use of a computer-assisted surgical navigation system, and the other was replaced conventionally without use of computer-assisted surgical navigation. The two methods were compared for accuracy of orientation and alignment of the components as determined by radiographs and computed tomography scans. The mean duration of follow-up was 3.4 years.
RESULTS: The mean preoperative Knee Society score was 26 points, with an improvement to 92 points postoperatively, in the computer-assisted total knee arthroplasty group and 25 points, with an improvement to 93 points postoperatively, in the conventional total knee arthroplasty group. Preoperative and postoperative ranges of motion of the knees were similar in both groups. The operating and tourniquet times were significantly longer in the computer-assisted total knee arthroplasty group than in the conventional total knee arthroplasty group (p < 0.001). The groups were not significantly different with regard to the accuracy of component positioning and the number of outliers for the various radiographic parameters (p > 0.05).
CONCLUSIONS: Our data demonstrate that total knee arthroplasty with use of computer-assisted surgical navigation did not result in more accurate implant positioning than that achieved in conventional total knee arthroplasty, as determined by both radiographs and computed tomography scans.

Entities:  

Mesh:

Year:  2009        PMID: 19122074     DOI: 10.2106/JBJS.G.01700

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  46 in total

1.  CT measurements prior to computer-assisted total knee arthroplasty do not improve rotational placement of the femoral component.

Authors:  A de Ladoucette
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12       Impact factor: 4.342

2.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

Review 3.  Alignment outcomes in navigated total knee arthroplasty: a meta-analysis.

Authors:  Yonghui Fu; Mingming Wang; Yifeng Liu; Qin Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

4.  Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study.

Authors:  Jörg Lützner; Klaus-Peter Günther; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-05       Impact factor: 4.342

Review 5.  Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

Authors:  Emil G Haritinian; Ashvin L Pimpalnerkar
Journal:  Maedica (Buchar)       Date:  2013-06

6.  Comparison of two minimally invasive implantation instrument-sets for total knee arthroplasty.

Authors:  Arno Martin; Mitchell B Sheinkop; Mary M Langhenry; Mark Widemschek; Thomas Benesch; Archibald von Strempel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-22       Impact factor: 4.342

Review 7.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

8.  [Computer-assisted total knee replacement (TKR) using Orthopilot navigation system].

Authors:  Michael N Magin
Journal:  Oper Orthop Traumatol       Date:  2010-03       Impact factor: 1.154

9.  Individual valgus correction angle improves accuracy of postoperative limb alignment restoration after total knee arthroplasty.

Authors:  Xiaojun Shi; Hai Li; Zongke Zhou; Bin Shen; Jing Yang; Pengde Kang; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-01       Impact factor: 4.342

Review 10.  Current concepts and future perspectives in computer-assisted navigated total knee replacement.

Authors:  Tomoyuki Matsumoto; Naoki Nakano; John E Lawrence; Vikas Khanduja
Journal:  Int Orthop       Date:  2018-05-12       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.