Validation of subject-specific automated p-FE analysis of the proximal femur.

Nir Trabelsi1, Zohar Yosibash, Charles Milgrom.   

Abstract

BACKGROUND: The use of subject-specific finite element (FE) models in clinical practice requires a high level of automation and validation. In Yosibash et al. [2007a. Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations. J. Biomechanics 40, 3688-3699] a novel method for generating high-order finite element (p-FE) models from CT scans was presented and validated by experimental observations on two fresh frozen femurs (harvested from a 30 year old male and 21 year old female). Herein, we substantiate the validation process by enlarging the experimental database (54 year old female femur), improving the method and examine its robustness under different CT scan conditions. APPROACH: A fresh frozen femur of a 54 year old female was scanned under two different environments: in air and immersed in water (dry and wet CT). Thereafter, the proximal femur was quasi-statically loaded in vitro by a 1000N load. The two QCT scans were manipulated to generate p-FE models that mimic the experimental conditions. We compared p-FE displacements and strains of the wet CT model to the dry CT model and to the experimental results. In addition, the material assignment strategy was reinvestigated. The inhomogeneous Young's modulus was represented in the FE model using two different methods, directly extracted from the CT data and using continuous spatial functions as in Yosibash et al. [2007a. Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations. J. Biomechanics 40, 3688-3699].
RESULTS: Excellent agreement between dry and wet FE models was found for both displacements and strains, i.e. the method is insensitive to CT conditions and may be used in vivo. Good agreement was also found between FE results and experimental observations. The spatial functions representing Young's modulus are local and do not influence strains and displacements prediction. Finally, the p-FE results of all three fresh frozen human femurs compare very well to experimental observations exemplifying that the presented method may be in a mature stage to be used in clinical computer-aided decision making.

Entities:  

Mesh:

Year:  2008        PMID: 19118831     DOI: 10.1016/j.jbiomech.2008.10.039

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  [Stability of volar fixed-angle plating for distal radius fractures. Failure modes in osteoporotic bone].

Authors:  S Mair; P Weninger; F Högel; S Panzer; P Augat
Journal:  Unfallchirurg       Date:  2013-04       Impact factor: 1.000

2.  An experimentally validated micromechanical model of a rat vertebra under compressive loading.

Authors:  Naomi Tsafnat; Stephen Wroe
Journal:  J Anat       Date:  2010-08-31       Impact factor: 2.610

3.  QCT-based failure analysis of proximal femurs under various loading orientations.

Authors:  Majid Mirzaei; Maziyar Keshavarzian; Fatemeh Alavi; Pegah Amiri; Saeid Samiezadeh
Journal:  Med Biol Eng Comput       Date:  2015-03-03       Impact factor: 2.602

4.  Strain in the ostrich mandible during simulated pecking and validation of specimen-specific finite element models.

Authors:  Emily J Rayfield
Journal:  J Anat       Date:  2010-09-16       Impact factor: 2.610

5.  Study of the variations of fall induced hip fracture risk between right and left femurs using CT-based FEA.

Authors:  Tanvir R Faisal; Yunhua Luo
Journal:  Biomed Eng Online       Date:  2017-10-03       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.