Literature DB >> 19110259

Effect of analyte properties on the kinetic performance of liquid chromatographic separations.

André de Villiers1, Frédéric Lynen, Pat Sandra.   

Abstract

Advances in modern high-performance liquid chromatography (HPLC) have led to increased interest in the comparison of the ultimate performance limits of methodologies aimed at increasing the resolving power per unit time. Kinetic plot-based methods have proven invaluable in facilitating such evaluations. However, in bridging the gap between fundamental comparisons and the eventual practical applicability of kinetic performance data, the effect of analyte properties have thus far largely been neglected. Using pharmaceutical compounds as representative real-life analytes, it is demonstrated that noteworthy differences in the optimal kinetic performance of a chromatographic system are observed compared to data for common test compounds. For a given stationary phase particle size, higher optimal- and maximum plate numbers, corresponding to increased analysis times, are measured for pharmaceutical compounds. Moreover, it is found that the optimal particle size/maximum pressure combination depends on the analyte under investigation, with the beneficial range of efficiencies for small particles shifted towards higher plate numbers for drug molecules. It is further demonstrated that the pH of the mobile phase plays a crucial role in determining the kinetic performance of pharmaceutical compounds. These data clearly indicate that data for test compounds do not reflect the performance attainable for pharmaceutical compounds and highlights the importance of using real-life samples to perform kinetic evaluations.

Mesh:

Substances:

Year:  2008        PMID: 19110259     DOI: 10.1016/j.chroma.2008.11.101

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Repeatability of gradient ultrahigh pressure liquid chromatography-tandem mass spectrometry methods in instrument-controlled thermal environments.

Authors:  James P Grinias; Jenny-Marie T Wong; Robert T Kennedy
Journal:  J Chromatogr A       Date:  2016-07-18       Impact factor: 4.759

2.  Kinetic performance comparison of fully and superficially porous particles with sizes ranging between 2.7 μm and 5 μm: Intrinsic evaluation and application to a pharmaceutical test compound.

Authors:  K Broeckhoven; D Cabooter; G Desmet
Journal:  J Pharm Anal       Date:  2012-12-25

3.  Revising Reverse-Phase Chromatographic Behavior for Efficient Differentiation of Both Positional and Geometrical Isomers of Dicaffeoylquinic Acids.

Authors:  Keabetswe Masike; Ian Dubery; Paul Steenkamp; Elize Smit; Edwin Madala
Journal:  J Anal Methods Chem       Date:  2018-01-11       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.