Literature DB >> 19109030

Emergency treatment of the thoracic aorta: results in 113 consecutive acute patients (the Talent Thoracic Retrospective Registry).

Abdullah Kaya1, Robin H Heijmen, Hervé Rousseau, Christoph A Nienaber, Marek Ehrlich, Philippe Amabile, Jean-Paul Beregi, Rossella Fattori.   

Abstract

BACKGROUND: Elective thoracic endovascular aortic repair in selected patients with suitable aortic anatomy is associated with low morbidity and mortality, and is gaining widespread acceptance. Its benefit in acute thoracic aorta diseases, however, has not yet been demonstrated in high-numbered studies. This report presents data of the Talent Thoracic Retrospective Registry (TTR) of all patients who underwent endovascular stent grafting for acute thoracic aorta pathology.
METHODS: Between December 1996 and July 2004 data were collected regarding 113 consecutive patients who underwent emergent endovascular stent grafting of the thoracic aorta using the Talent thoracic stent graft (Medtronic, Inc., Santa Rosa, California) in 7 European referral centers. Acute thoracic aorta pathology consisted of 41 (36.3 %) traumatic aortic injuries, 37 (32.7 %) Stanford type B dissections, 5 (4.4 %) intramural hematomas, 18 (15.9 %) thoracic aorta aneurysms, 4 (3.5 %) pseudoaneurysms and 8 (7.1 %) penetrating ulcers.
RESULTS: In all patients the stent graft system could be introduced via the common femoral artery. Conversion to open surgical repair was necessary in 2 patients, one in the early phase due to persistent bleeding via backflow in the false lumen from a distal entry tear, and another patient in a late phase due to retrograde dissection. Intraoperative mortality was 1.8%, one patient suffered a massive myocardial infarction, and another died of tamponade secondary to retrograde dissection. Overall hospital mortality was 8.0% (9 patients). In only 2 of them, it was considered a stent graft procedure related death. New neurological symptoms were seen in 6.2% (7 patients), with complete recovery in 5 patients. Mean follow-up was 15 months (range 1-69 months). Late mortality was 8.7% (9 patients). Only one late death was considered aorta related. Overall re-intervention rate was 8.9% (n=10) and was mainly for type I endoleak or persistent false lumen perfusion.
CONCLUSION: Sub-analysis of the Talent Thoracic Retrospective Registry for endovascular stent grafting of acute thoracic aorta pathology in over 100 consecutive patients demonstrated its feasibility, with low morbidity and acceptable low mortality rates.

Entities:  

Mesh:

Year:  2008        PMID: 19109030     DOI: 10.1016/j.ejcts.2008.10.052

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Endovascular repair of thoracic and abdominal aortic ruptures: a single-center experience.

Authors:  Filiz İslim; Aysun Erbahçeci Salık; Koray Güven; Vedat Bakuy; Zafer Çukurova
Journal:  Diagn Interv Radiol       Date:  2014 May-Jun       Impact factor: 2.630

2.  Emergent repair of acute thoracic aortic catastrophes: a comparative analysis.

Authors:  Peter A Naughton; Michael S Park; Mark D Morasch; Heron E Rodriguez; Manuel Garcia-Toca; C Edward Wang; Mark K Eskandari
Journal:  Arch Surg       Date:  2012-03

Review 3.  Acute complicated and uncomplicated type III aortic dissection: an endovascular perspective.

Authors:  Castigliano M Bhamidipati; Gorav Ailawadi
Journal:  Semin Thorac Cardiovasc Surg       Date:  2009

4.  Usefulness of new imaging methods for assessment of type B aortic dissection.

Authors:  Rachel E Clough; Vassilios E Zymvragoudakis; Lukla Biasi; Peter R Taylor
Journal:  Ann Cardiothorac Surg       Date:  2014-05

5.  Post-traumatic acute thoracic aortic injury (TAI)-a single center experience.

Authors:  Piotr Buczkowski; Mateusz Puslecki; Sebastian Stefaniak; Robert Juszkat; Jerzy Kulesza; Bartłomiej Perek; Marcin Misterski; Tomasz Urbanowicz; Marcin Ligowski; Bartosz Zabicki; Marek Dabrowski; Lukasz Szarpak; Marek Jemielity
Journal:  J Thorac Dis       Date:  2017-11       Impact factor: 2.895

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.