Literature DB >> 1910665

In vitro testing of a simply constructed, highly stable glucose sensor suitable for implantation in diabetic patients.

G W Shaw1, D J Claremont, J C Pickup.   

Abstract

We have constructed and tested in vitro a potentially implantable, needle-type amperometric enzyme electrode which is suitable for continuous monitoring of glucose concentrations in diabetic patients. The major requirements of stability during operation and ease of manufacture have been met with a sensor design which involves a simple dip-coating procedure for applying to a platinum base electrode an inner membrane of glucose oxidase immobilised in polyhydroxyethyl methacrylate (pHEMA), and an outer membrane composed of a pHEMA/polyurethane mixture. Sensors were operated at 700 mV for detection of hydrogen peroxide. Calibration curves for the sensor were linear to at least 20 mM glucose and were unaffected by a reduction in PO2 from 20 to 5 kPa. During continuous operation in 5 mM buffered glucose solutions in vitro, sensors suffered no significant loss of response over periods of up to 60 h. Such electrodes are, therefore, useful for development as in vivo glucose sensors.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1910665     DOI: 10.1016/0956-5663(91)87004-u

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  Open flow microperfusion: approach to in vivo glucose monitoring.

Authors:  G P Rigby; P Crump; P Vadgama
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

Review 2.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

3.  Biofouling of polymer hydrogel materials and its effect on diffusion and enzyme-based luminescent glucose sensor functional characteristics.

Authors:  Jason R Roberts; Jaebum Park; Kristen Helton; Natalie Wisniewski; Michael J McShane
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

4.  Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man.

Authors:  J C Pickup; D J Claremont; G W Shaw
Journal:  Acta Diabetol       Date:  1993       Impact factor: 4.280

Review 5.  Over-the-Counter Biosensors: Past, Present, and Future.

Authors:  Thomas Ming-Hung Lee
Journal:  Sensors (Basel)       Date:  2008-09-06       Impact factor: 3.576

Review 6.  Application of Semipermeable Membranes in Glucose Biosensing.

Authors:  Tanmay Kulkarni; Gymama Slaughter
Journal:  Membranes (Basel)       Date:  2016-12-14

Review 7.  In-Vivo Microsystems: A Review.

Authors:  Paddy French
Journal:  Sensors (Basel)       Date:  2020-09-01       Impact factor: 3.576

8.  Ultrasound Intra Body Multi Node Communication System for Bioelectronic Medicine.

Authors:  Banafsaj Jaafar; JunWen Luo; Dimitrios Firfilionis; Ahmed Soltan; Jeff Neasham; Patrick Degenaar
Journal:  Sensors (Basel)       Date:  2019-12-19       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.