Optic nerve ultrasound for detection of intracranial hypertension in intracranial hemorrhage patients: confirmation of previous findings in a different patient population.

Riccardo Moretti1, Barbara Pizzi.   

Abstract

Bedside ultrasonographic measurement of optic nerve sheath diameter (ONSD) has been proposed as a method to detect raised intracranial pressure (ICP) in various clinical settings. The aim of our study is to evaluate the use of ultrasonography in the case of intracranial hemorrhage and to assess the validity of the conventional cut-off point of 5 mm. A prospective blind observational study in a 10-bed multivalent intensive care unit was carried out by enrolling 53 adult patients with primary intracerebral hemorrhage (23) or subarachnoid hemorrhage (30), requiring ICP monitoring, sedation, and mechanical ventilation and 53 control patients with no intracranial pathology, requiring sedation and mechanical ventilation. ONSD was measured 3 mm behind the globe by using a 7.5 MHz linear ultrasound probe. Mean binocular ONSD was used for data analysis. Nineteen patients proved to have raised ICP (>20 mm Hg). In this group, ONSD at admission was 6.2+/-0.6 mm, a significantly higher value than in low ICP patients (P<0.01). In the 34 patients with ICP <20 mm Hg, ONSD was 5.0+/-0.5 mm, and it resulted not significantly different from ONSD in the control group (4.9+/-0.4 mm). A receiver operator characteristic curve was constructed and an ONSD threshold of 5.2 mm as a predictor of ICP >20 mm Hg proved to be an attractive combination of sensitivity and specificity (94% and 76%, respectively). In conclusion, our study confirms the utility of optic nerve ultrasound in the early diagnostic evaluation of patients with known or suspected intracranial hemorrhage.

Entities:  

Mesh:

Year:  2009        PMID: 19098619     DOI: 10.1097/ANA.0b013e318185996a

Source DB:  PubMed          Journal:  J Neurosurg Anesthesiol        ISSN: 0898-4921            Impact factor:   3.956


  38 in total

1.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

2.  Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi; Fabrizio Cassini; Nicoletta Vivaldi
Journal:  Neurocrit Care       Date:  2009-12       Impact factor: 3.210

3.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 4.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

5.  Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.

Authors:  Chiara Robba; Gregorio Santori; Marek Czosnyka; Francesco Corradi; Nicola Bragazzi; Llewellyn Padayachy; Fabio Silvio Taccone; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-07-17       Impact factor: 17.440

6.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

7.  Noninvasive Intracranial Pressure Assessment in Acute Liver Failure.

Authors:  Venkatakrishna Rajajee; Craig A Williamson; Robert J Fontana; Anthony J Courey; Parag G Patil
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

8.  The Authors Reply: Is Optic Nerve Sheath Diameter a Reliable Proxy for Intracranial Pressure in Patients with Subarachnoid Hemorrhage?

Authors:  Tommaso Zoerle; Nino Stocchetti
Journal:  Neurocrit Care       Date:  2020-10       Impact factor: 3.210

9.  Optic nerve ultrasound for the detection of raised intracranial pressure.

Authors:  Venkatakrishna Rajajee; Monique Vanaman; Jeffrey James Fletcher; Teresa Lee Jacobs
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

10.  Sonography of the optic nerve sheath beyond the hyperacute stage of intracerebral hemorrhage.

Authors:  Piergiorgio Lochner; Cornelia Mader; Raffaele Nardone; Frediano Tezzon; Maria Luisa Zedde; Giovanni Malferrari; Francesco Brigo
Journal:  J Ultrasound       Date:  2014-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.