Literature DB >> 19098204

Frequency and upgrade rates of atypical ductal hyperplasia diagnosed at stereotactic vacuum-assisted breast biopsy: 9-versus 11-gauge.

Peter R Eby1, Jennifer E Ochsner, Wendy B DeMartini, Kimberly H Allison, Sue Peacock, Constance D Lehman.   

Abstract

OBJECTIVE: Our goals were to determine the frequency and upgrade rate for atypical ductal hyperplasia (ADH) diagnosed with stereotactic 9-gauge vacuum-assisted breast biopsy and to compare the frequencies and upgrade rates of ADH between 9- and 11-gauge vacuum-assisted breast biopsy.
MATERIALS AND METHODS: We retrospectively reviewed the pathology results of 991 consecutive 9- or 11-gauge stereotactic vacuum-assisted breast biopsy procedures from February 2001 through June 2006 and identified lesions diagnosed as ADH. The final diagnosis after surgical excision was determined from medical records. The frequencies and upgrade rates to carcinoma were calculated for all ADH lesions and compared between 9- and 11-gauge procedures. The number of core samples was recorded and compared.
RESULTS: One hundred forty-one of 991 (14.2%) lesions yielded a diagnosis of ADH at 9- or 11-gauge stereotactic vacuum-assisted breast biopsy. Upgrade to ductal carcinoma in situ or invasive carcinoma occurred in 26 of 123 (21.1%) patients. The frequency of ADH was 83 of 600 (13.8%) lesions for 9-gauge and 58 of 391 (14.8%) lesions for 11-gauge vacuum-assisted breast biopsy. The 9-gauge upgrade rate was 16 of 74 (21.6%) lesions compared with 10 of 49 (20.4%) lesions for 11-gauge vacuum-assisted breast biopsy. There was no significant difference between the number of core samples obtained with each device (p=0.40). Neither the frequency of ADH (p=0.66) nor the upgrade rates (p=0.87) were significantly different between 9- and 11-gauge vacuum-assisted breast biopsy.
CONCLUSION: Compared with an 11-gauge vacuum-assisted breast biopsy device, the use of a larger 9-gauge vacuum-assisted breast biopsy needle does not decrease the upgrade rate of ADH. Our frequency of ADH at vacuum-assisted breast biopsy is higher than any previously reported and may reflect regional differences in the incidence of breast cancer or practice patterns of the pathologist.

Entities:  

Mesh:

Year:  2009        PMID: 19098204     DOI: 10.2214/AJR.08.1342

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  21 in total

1.  B3 Lesions: Radiological Assessment and Multi-Disciplinary Aspects.

Authors:  Sylvia H Heywang-Köbrunner; Jörg Nährig; Astrid Hacker; Stefan Sedlacek; Heinz Höfler
Journal:  Breast Care (Basel)       Date:  2010-08-23       Impact factor: 2.860

2.  Early Breast Cancer Precursor Lesions: Lessons Learned from Molecular and Clinical Studies.

Authors:  Hans-Peter Sinn; Zeinab Elsawaf; Birgit Helmchen; Sebastian Aulmann
Journal:  Breast Care (Basel)       Date:  2010-08-23       Impact factor: 2.860

3.  Minimally Invasive Biopsy Methods - Diagnostics or Therapy? Personal Opinion and Review of the Literature.

Authors:  Ute Kettritz
Journal:  Breast Care (Basel)       Date:  2011-04-29       Impact factor: 2.860

4.  Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

Authors:  Sung Eun Song; Nariya Cho; Wonshik Han
Journal:  Eur Radiol       Date:  2017-07-07       Impact factor: 5.315

5.  Diagnostic underestimation of atypical ductal hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution.

Authors:  Gustavo Machado Badan; Decio Roveda Júnior; Sebastião Piato; Eduardo de Faria Castro Fleury; Mário Sérgio Dantas Campos; Carlos Alberto Ferreira Pecci; Felipe Augusto Trocoli Ferreira; Camila D'Ávila
Journal:  Radiol Bras       Date:  2016 Jan-Feb

Review 6.  How Do We Approach Benign Proliferative Lesions?

Authors:  Faina Nakhlis
Journal:  Curr Oncol Rep       Date:  2018-03-23       Impact factor: 5.075

7.  High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: can underestimation be predicted?

Authors:  Pavel Crystal; Arifa Sadaf; Karina Bukhanov; David McCready; Frances O'Malley; Thomas H Helbich
Journal:  Eur Radiol       Date:  2010-09-14       Impact factor: 5.315

8.  Trends in breast biopsy pathology diagnoses among women undergoing mammography in the United States: a report from the Breast Cancer Surveillance Consortium.

Authors:  Kimberly H Allison; Linn A Abraham; Donald L Weaver; Anna N A Tosteson; Heidi D Nelson; Tracy Onega; Berta M Geller; Karla Kerlikowske; Patricia A Carney; Laura E Ichikawa; Diana S M Buist; Joann G Elmore
Journal:  Cancer       Date:  2015-01-20       Impact factor: 6.860

9.  Rates of atypical ductal hyperplasia have declined with less use of postmenopausal hormone treatment: findings from the Breast Cancer Surveillance Consortium.

Authors:  Tehillah S Menes; Karla Kerlikowske; Shabnam Jaffer; Deborah Seger; Diana L Miglioretti
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2009-11       Impact factor: 4.254

Review 10.  High-risk lesions of the breast: concurrent diagnostic tools and management recommendations.

Authors:  Francesca Catanzariti; Daly Avendano; Giuseppe Cicero; Margarita Garza-Montemayor; Carmelo Sofia; Emmanuele Venanzi Rullo; Giorgio Ascenti; Katja Pinker-Domenig; Maria Adele Marino
Journal:  Insights Imaging       Date:  2021-05-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.