Literature DB >> 19098172

Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma.

Duy Nguyen1, Alexandra Platon, Kathirkamanathan Shanmuganathan, Stuart E Mirvis, Christoph D Becker, Pierre-Alexandre Poletti.   

Abstract

OBJECTIVE: The purpose of this study was to compare a conventional multiregional MDCT protocol with two continuous single-pass whole-body MDCT protocols in imaging of patients with polytrauma. SUBJECTS AND METHODS: Ninety patients with polytrauma underwent whole-body 16-MDCT with a conventional (n=30) or one of two single-pass (n=60) protocols. The conventional protocol included unenhanced scans of the head and cervical spine and contrast-enhanced helical scans (140 mL, 4 mL/s, 300 mg I/mL) of the thorax and abdomen. The single-pass protocols consisted of unenhanced scans of the head followed by one-sweep acquisition from the circle of Willis through the pubic symphysis with a biphasic (150 mL, 6 and 4 mL/s, 300 mg I/mL) or monophasic (110 mL, 4 mL/s, 400 mg I/mL) injection. Acquisition times and interval delays between head, chest, and abdominal scans were recorded. Contrast enhancement was measured in the aortic arch, liver, spleen, and kidney. Diagnostic image quality in the same areas was assessed on a 4-point scale.
RESULTS: Median acquisition times for the single-pass protocols were significantly shorter (-42.5%) than the acquisition time for the conventional protocol. No significant differences were found in mean enhancement values in the aorta, liver, spleen, and kidney for the three protocols. The image quality with both single-pass protocols was better than that with the conventional protocol in assessment of the mediastinum and cervical spine (p<0.05). There was no significant difference between the single-pass protocols.
CONCLUSION: Use of single-pass continuous whole-body MDCT protocols can significantly decrease examination time for patients with polytrauma and improve image quality compared with a conventional serial scan protocol. Monophasic injection with highly concentrated contrast medium can reduce injection flow rate and should therefore be preferred to a biphasic injection technique.

Entities:  

Mesh:

Year:  2009        PMID: 19098172     DOI: 10.2214/AJR.07.3702

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  18 in total

1.  Rapid imaging protocol in trauma: a whole-body dual-source CT scan.

Authors:  Anto Sedlic; Christina M Chingkoe; David K Tso; Sandro Galea-Soler; Savvas Nicolaou
Journal:  Emerg Radiol       Date:  2013-06-21

2.  Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality.

Authors:  Christoph Karlo; Ralph Gnannt; Thomas Frauenfelder; Sebastian Leschka; Martin Brüesch; Guido A Wanner; Hatem Alkadhi
Journal:  Emerg Radiol       Date:  2011-04-07

Review 3.  Postmortem-computed tomography and postmortem-computed tomography-angiography: a focused update.

Authors:  Francesco Paolo Busardò; Paola Frati; Giuseppe Guglielmi; Giampaolo Grilli; Antonio Pinto; Antonio Rotondo; Valeria Panebianco; Vittorio Fineschi
Journal:  Radiol Med       Date:  2015-06-19       Impact factor: 3.469

4.  Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis.

Authors:  S Gordic; H Alkadhi; S Hodel; H-P Simmen; M Brueesch; T Frauenfelder; G Wanner; K Sprengel
Journal:  Br J Radiol       Date:  2015-01-16       Impact factor: 3.039

Review 5.  Battlefield radiology.

Authors:  R N J Graham
Journal:  Br J Radiol       Date:  2012-07-17       Impact factor: 3.039

6.  Splenic parenchymal heterogeneity at dual-bolus single-acquisition CT in polytrauma patients-6-months experience from Oxford, UK.

Authors:  Jonathan M Stedman; Jamie M Franklin; Helen Nicholl; Ewan M Anderson; Niall R Moore
Journal:  Emerg Radiol       Date:  2014-01-09

7.  The additional value of the arterial phase in the CT assessment of liver vascular injuries after high-energy blunt trauma.

Authors:  Francesca Iacobellis; Mariano Scaglione; Antonio Brillantino; Maria Giuseppina Scuderi; Francesco Giurazza; Roberto Grassi; Giuseppe Noschese; Raffaella Niola; Naail Yarub Sulaiman Al Zuhir; Luigia Romano
Journal:  Emerg Radiol       Date:  2019-08-23

8.  Trauma whole-body MDCT: an assessment of image quality in conventional dual-phase and modified biphasic injection.

Authors:  Wasim Hakim; Raghavendra Kamanahalli; Elizabeth Dick; Nishat Bharwani; Shirley Fetherston; Elika Kashef
Journal:  Br J Radiol       Date:  2016-05-17       Impact factor: 3.039

9.  Imaging features of blast injuries: experience from 2015 Ankara bombing in Turkey.

Authors:  Cisel Yazgan; Nalan M Aksu
Journal:  Br J Radiol       Date:  2016-03-09       Impact factor: 3.039

Review 10.  A review of split-bolus single-pass CT in the assessment of trauma patients.

Authors:  Cassandra Jeavons; Craig Hacking; Ludo F Beenen; Martin L Gunn
Journal:  Emerg Radiol       Date:  2018-02-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.