Literature DB >> 19097696

Membrane optode for mercury(II) determination in aqueous samples.

Y Kalyan1, A K Pandey, P R Bhagat, R Acharya, V Natarajan, G R K Naidu, A V R Reddy.   

Abstract

A color changeable optode for Hg(II) was prepared by the immobilization of a dye 4-(2-pyridylazo)resorcinol (PAR) and a liquid ion-exchanger trioctylmethylammonium chloride (Aliquat-336) in the tri-(2-ethylhexyl) phosphate plasticized cellulose triacetate matrix. Hg(II) and CH(3)Hg(+) from aqueous samples could be quantitatively preconcentrated in this transparent optode producing a distinct color change (lambda(max)=520 nm) within 5 min equilibration time in bicarbonate aqueous medium or 30 min in natural water. Whereas optode sample without Aliquat-336 did not change its color corresponding to Hg-PAR complex on equilibrium with the same aqueous solution containing Hg(II) ions. The uptake of Hg(II) was found to be pH dependent with a maximum (>90%) at a pH 7.5. The uptake of ions like Cu(II), Fe(II), Zn(II) and Pb(II) was negligible in the optode where as the uptake of Cd(II) and Zn(II) ions was 10-15% at pH 7.5. The optode developed in the present work was studied for its analytical application for Hg(II) in the aqueous samples by spectrophotometry, radiotracer ((203)Hg), Energy Dispersive X-ray Fluorescence (EDXRF) analyses and Instrumental Neutron Activation Analysis (INAA). The minimum amount of Hg(II) required to produce detectable response by spectrophotometry, INAA and EDXRF were found to be 5.5, 1 and 12 microg, respectively. This optode showed a linear increase in the absorbance at lambda(max)=520 nm over a concentration range of 0.22-1.32 microg/mL of Hg(II) ions in aqueous solution for 5 min. The preconcentration of Hg(II) from large volume of aqueous solution was used to extend the lower limit of concentration range that can be quantified by the spectrophotometry of optode. It was observed that preconcentration of 11 microg Hg(II) in 100mL (0.11 microg/mL) in aqueous samples gives a distinct color change and absorbance above 3 sigma of the blank absorbance. The optode developed in the present work was found to be reusable.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19097696     DOI: 10.1016/j.jhazmat.2008.11.027

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  4 in total

1.  Development of an optode for detection of trace amounts of Hg2+ in different real samples based on immobilization of novel tetradentate Schiff bases bearing two thiol groups in PVC membrane.

Authors:  Ayman A Abdel Aziz; Soha F Mohammed; Magdy M El Gamel
Journal:  J Fluoresc       Date:  2014-02-12       Impact factor: 2.217

Review 2.  Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review.

Authors:  Philippe Namour; Mathieu Lepot; Nicole Jaffrezic-Renault
Journal:  Sensors (Basel)       Date:  2010-08-26       Impact factor: 3.576

3.  Recognition of trace organic pollutant and toxic metal ions via a tailored fluorescent metal-organic coordination polymer in water environment.

Authors:  Danfeng He; Shumei Liu; Fujiang Zhou; Xianjun Zhao; Yiwei Liu; Fang Luo; Shuxia Liu
Journal:  RSC Adv       Date:  2018-10-09       Impact factor: 4.036

Review 4.  Recent progress in optical chemical sensors.

Authors:  Hummad Habib Qazi; Abu Bakar bin Mohammad; Muhammad Akram
Journal:  Sensors (Basel)       Date:  2012-11-29       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.