Literature DB >> 19096175

X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice.

Tohoru Takeda1, Jin Wu, Qingkai Huo, Tetsuya Yuasa, Kazuyuki Hyodo, F Avraham Dilmanian, Takao Akatsuka.   

Abstract

Using X-ray fluorescent computed tomography (XFCT), the in vivo and ex vivo cerebral distribution of a stable-iodine-labeled cerebral perfusion agent, iodoamphetamine analog (127I-IMP), has been recorded in the brains of mice. In vivo cerebral perfusion in the cortex, hippocampus and thalamus was depicted at 0.5 mm in-plane spatial resolution. Ex vivo XFCT images at 0.25 mm in-plane spatial resolution allowed the visualisation of the detailed structures of these regions. The quality of the XFCT image of the hippocampus was comparable with the 125I-IMP autoradiogram. These results highlight the sensitivity of XFCT and its considerable potential to evaluate cerebral perfusion in small animals without using radioactive agents.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19096175     DOI: 10.1107/S0909049508031853

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  8 in total

Review 1.  The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging.

Authors:  Magdalena Bazalova-Carter
Journal:  Br J Radiol       Date:  2015-07-24       Impact factor: 3.039

2.  L-shell x-ray fluorescence computed tomography (XFCT) imaging of Cisplatin.

Authors:  Magdalena Bazalova; Moiz Ahmad; Guillem Pratx; Lei Xing
Journal:  Phys Med Biol       Date:  2013-12-13       Impact factor: 3.609

3.  Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.

Authors:  Don Vernekohl; Moiz Ahmad; Garry Chinn; Lei Xing
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

4.  Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

Authors:  Moiz Ahmad; Magdalena Bazalova; Liangzhong Xiang; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

Review 5.  Advances in functional X-ray imaging techniques and contrast agents.

Authors:  Hongyu Chen; Melissa M Rogalski; Jeffrey N Anker
Journal:  Phys Chem Chem Phys       Date:  2012-10-21       Impact factor: 3.676

6.  Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography.

Authors:  Nivedh Manohar; Francisco J Reynoso; Parmeswaran Diagaradjane; Sunil Krishnan; Sang Hyun Cho
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

7.  Dual-energy fluorescent x-ray computed tomography system with a pinhole design: Use of K-edge discontinuity for scatter correction.

Authors:  Tenta Sasaya; Naoki Sunaguchi; Thet- Thet-Lwin; Kazuyuki Hyodo; Tsutomu Zeniya; Tohoru Takeda; Tetsuya Yuasa
Journal:  Sci Rep       Date:  2017-03-08       Impact factor: 4.379

8.  Multi-pinhole fluorescent x-ray computed tomography for molecular imaging.

Authors:  Tenta Sasaya; Naoki Sunaguchi; Kazuyuki Hyodo; Tsutomu Zeniya; Tetsuya Yuasa
Journal:  Sci Rep       Date:  2017-07-18       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.