Steve Dutil1, Anne Meriaux, Marie-Chantale de Latremoille, Louis Lazure, Jean Barbeau, Caroline Duchaine.
Abstract
Dynamic dental instruments generate abundant aerosols in the work environment. Dental unit waterlines (DUWL) support a large microbial population and can be a significant source of bioaerosols generated during dental treatments. This study was conducted to characterize bioaerosol generation during dental treatments performed in standardized conditions. Culture-based method (R2A, and blood agar with and without O2) and fluorescence microscopy were used. Dental cleaning procedures were performed in an isolated treatment room with controlled ventilation rate. Andersen microbial samplers were used to collect culturable bioaerosols generated before (baseline), during, and after 2 hr of dental treatments. Inhalable dust samplers were used to measure total bioaerosols content in dental hygienist's and patients' breathing zones. AGI-30 were used for the collection of the endotoxin. The use of fluorescence microscopy in combination with culture demonstrated that dental staff and patients were exposed to up to 1.86 E+05 bacteria/m(3) generated during treatments. Fortunately, bioaerosols returned to baseline within 2 hr after the dental procedures. The small diameter of the aerosols generated (< 1 microm) suggests that the risk of contact between the aerosolized bacteria and the respiratory system of exposed individuals is likely to occur.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19093289 DOI: 10.1080/15459620802633957
Source DB: PubMed Journal: J Occup Environ Hyg ISSN: 1545-9624 Impact factor: 2.155