Literature DB >> 19091898

Quantification of left ventricular volumes and ejection fraction in mice using PET, compared with MRI.

Lars Stegger1, Edwin Heijman, Klaus P Schäfers, Klaas Nicolay, Michael A Schäfers, Gustav J Strijkers.   

Abstract

UNLABELLED: PET has become an important noninvasive imaging technique in cardiovascular research for the characterization of mouse models in vivo. This modality offers unique insight into biochemical changes on a molecular level, with excellent sensitivity. However, morphologic and functional changes may be of equal importance for a thorough assessment of left ventricular (LV) pathophysiology. Although echocardiography and MRI are widely considered the imaging techniques of choice for the assessment of these parameters, their use with PET considerably increases study complexity and decreases cost- and time-efficiency. In this study, a novel method for the additional quantification of LV volumes and ejection fraction (EF) from PET was evaluated using cardiac MRI as the reference method.
METHODS: The radiolabeled glucose derivative 18F-FDG was injected into 33 mice (6 mice with previous permanent occlusion of the left anterior descending artery [LAD], 15 mice with a temporary 30-min occlusion of the LAD, and 12 mice without previous surgery). 18F-FDG uptake within the LV myocardium was measured using a dedicated small-animal PET scanner. After we reconstructed the images into 16 electrocardiogram (ECG)-gated frames, we determined the LV cavity volumes in end-diastole (EDV) and end-systole (ESV) and the EF using a semiautomatic segmentation algorithm based on elastic surfaces. A 6.3-T cardiac MRI examination was performed in the same animals using an ECG-triggered and respiratory-gated multislice cine sequence. The MR images were segmented with a semiautomatic algorithm using commercially available software.
RESULTS: Overall, measurements from PET agreed well with those obtained by MRI. Mean EDV and ESV were slightly overestimated by PET (86+/-43 microL and 44+/-42 microL), compared with MRI (73+/-44 microL and 41+/-46 microL); mean (+/-SD) EF was similar (PET, 55+/-19 microL; MRI, 54+/-18 microL). Correlation between PET and MRI was excellent for EDV (0.97) and ESV (0.96) and good for EF (0.86). The slope of the regression line was nearly perfect for EDV (0.98) and EF (1.01) and slightly below 1 for ESV (0.90), indicating a good separation of abnormal and normal values with PET. The y-intercept was above zero for EDV (15 microL) and ESV (7 microL) and near to zero for EF (0.2%).
CONCLUSION: The quantification of LV volumes and EF in mice with PET is both efficient and accurate. This method allows for combined molecular and functional imaging of the left ventricle within a single scan, obviating additional sophisticated MRI in many cases.

Entities:  

Mesh:

Year:  2008        PMID: 19091898     DOI: 10.2967/jnumed.108.056051

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  17 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Positron emission tomography in the assessment of left ventricular function in healthy rats: a comparison of four imaging methods.

Authors:  Andrei Todica; Guido Böning; Sebastian Lehner; Eliane Weidl; Paul Cumming; Carmen Wängler; Stephan G Nekolla; Markus Schwaiger; Peter Bartenstein; Ralf Schirrmacher; M Hacker
Journal:  J Nucl Cardiol       Date:  2012-12-19       Impact factor: 5.952

3.  In Vivo Labeling of Serum Albumin for PET.

Authors:  Gang Niu; Lixin Lang; Dale O Kiesewetter; Ying Ma; Zhongchan Sun; Ning Guo; Jinxia Guo; Chenxi Wu; Xiaoyuan Chen
Journal:  J Nucl Med       Date:  2014-05-19       Impact factor: 10.057

4.  In-vivo monitoring of erythropoietin treatment after myocardial infarction in mice with [⁶⁸Ga]Annexin A5 and [¹⁸F]FDG PET.

Authors:  Andrei Todica; Mathias J Zacherl; Hao Wang; Guido Böning; Nathalie L Jansen; Carmen Wängler; Peter Bartenstein; Michael C Kreissl; Marcus Hacker; Stefan Brunner; Sebastian Lehner
Journal:  J Nucl Cardiol       Date:  2014-09-05       Impact factor: 5.952

5.  Determination of three-dimensional ventricular strain distributions in gene-targeted mice using tagged MRI.

Authors:  Joyce S Chuang; Alice Zemljic-Harpf; Robert S Ross; Lawrence R Frank; Andrew D McCulloch; Jeffrey H Omens
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

6.  Left ventricular ejection fraction: real-world comparison between cardiac computed tomography and echocardiography in a large population.

Authors:  E Maffei; G Messalli; A Palumbo; C Martini; S Seitun; A Aldrovandi; A Cuttone; E Emiliano; R Malagò; A Weustink; N Mollet; F Cademartiri
Journal:  Radiol Med       Date:  2010-03-09       Impact factor: 3.469

7.  Measuring right ventricular function in the normal and hypertensive mouse hearts using admittance-derived pressure-volume loops.

Authors:  Diana M Tabima; Timothy A Hacker; Naomi C Chesler
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-10-08       Impact factor: 4.733

8.  [68Ga]-albumin-PET in the monitoring of left ventricular function in murine models of ischemic and dilated cardiomyopathy: comparison with cardiac MRI.

Authors:  Andrei Todica; Stefan Brunner; Guido Böning; Sebastian Lehner; Stephan G Nekolla; Moritz Wildgruber; Christopher Übleis; Carmen Wängler; Martina Sauter; Karin Klingel; Paul Cumming; Peter Bartenstein; Ralf Schirrmacher; Wolfgang Michael Franz; Marcus Hacker
Journal:  Mol Imaging Biol       Date:  2013-08       Impact factor: 3.488

9.  Novel role for vinculin in ventricular myocyte mechanics and dysfunction.

Authors:  Jared R Tangney; Joyce S Chuang; Matthew S Janssen; Adarsh Krishnamurthy; Peter Liao; Masahiko Hoshijima; Xin Wu; Gerald A Meininger; Mariappan Muthuchamy; Alice Zemljic-Harpf; Robert S Ross; Lawrence R Frank; Andrew D McCulloch; Jeffrey H Omens
Journal:  Biophys J       Date:  2013-04-02       Impact factor: 4.033

10.  Comparison of 4D-microSPECT and microCT for murine cardiac function.

Authors:  Nicholas T Befera; Cristian T Badea; G Allan Johnson
Journal:  Mol Imaging Biol       Date:  2014-04       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.