Abstract
Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 sec, and manufacturing microwave cycle - 320W/3 min + 0W/3 min + 720W/3 min); T (Clássico, water bath cycle - 74 degrees C/9h) and Q (Jet, press chamber cycle - 50 degrees C/15 min at 2 bar). Ten specimens (65 x 10 x 3.3mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 +/- 5.31; B = 107.57 +/- 3.99; C = 109.63 +/- 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 +/- 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.Entities:
Year: 2007 PMID: 19089173 PMCID: PMC4327264 DOI: 10.1590/s1678-77572007000500010
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Acrylic resins and polymerization cycles used in this study
| Material | Lot number | Manufacturer | Polymerization cycle |
|---|---|---|---|
|
| 404050 | Artigos Odontológicos Clássico Ltd, São Paulo, SP, Brazil | A: Microwave oven: 500 W for 3 min |
|
| 404050 | Artigos Odontológicos Clássico Ltd | B: Microwave oven: 90 W for 13 min + 500 W for 90 sec |
|
| 404050 | Artigos Odontológicos Clássico Ltd | C: Microwave oven: 320 W for 3 min + 0 W for 4 min + 720 W for 3 min |
|
| 404050 | Artigos Odontológicos Clássico Ltd | T: Conventional water bath: 74°C for 9 h |
|
| 404050 | Artigos Odontológicos Clássico Ltd | Q: Press chamber: 50°C for 15 min at 2 bar |
Cycle recommended by Onda-Cryl manufacturer.
Means and standard deviations for flexural strength tests (MPa)
| Cycle | ||||
|---|---|---|---|---|
| A | B | C | T | Q |
| 106.97a (±5.31) | 107.57a (±3.99) | 109.63a (±5.19) | 84.40b (±1.68) | 92.84c (±4.73) |
Different letters indicate statistically significant difference at 5%.