Literature DB >> 19089173

Flexural strength of acrylic resins polymerized by different cycles.

Débora Barros Barbosa1, Raphael Freitas de Souza, Ana Carolina Pero, Juliê Marra, Marco Antonio Compagnoni.   

Abstract

Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 sec, and manufacturing microwave cycle - 320W/3 min + 0W/3 min + 720W/3 min); T (Clássico, water bath cycle - 74 degrees C/9h) and Q (Jet, press chamber cycle - 50 degrees C/15 min at 2 bar). Ten specimens (65 x 10 x 3.3mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 +/- 5.31; B = 107.57 +/- 3.99; C = 109.63 +/- 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 +/- 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.

Entities:  

Year:  2007        PMID: 19089173      PMCID: PMC4327264          DOI: 10.1590/s1678-77572007000500010

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Poly(methyl methacrylate) (PMMA) is the most commonly used denture base resin, and its polymerization process may take place by different mechanisms8. Several processing methods have been proposed to simplify the technique and to reduce denture manufacturing time, in spite of the long acceptance of compression molding with the water-bath polymerization method. The convenience of using microwave energy in the food industry suggested similar advantages for denture processing. However, microwaved system have gained only limited clinical acceptance despite extensive laboratory research1,2,5,7,24. In previous studies, most of the mechanical properties of denture base resins polymerized by microwave energy and conventional water-bath method were comparable2,17,19,21. Reitz, et al.17(1985) and Shlosberg, et al.19 (1989) observed that the strength of the denture base resin polymerized by microwave was not significantly different by microwave-polymerized denture base resin. Alkhatib, et al.2 (1990) compared two microwave and one water bath-polymerized resins. No significant differences in flexural strengths were found regardless of the polymerization method. Other works3,21 showed higher flexural strength for microwave-processed acrylic resins. Some authors11,12,14 have reported that high levels of residual monomer have a deleterious effect on the mechanical properties of denture base polymers. Also, the level of residual monomer and the mechanical properties are closely related to the polymerization conditions10. Harrison and Huggett12 (1992) evaluated the effect of the polymerization cycle on residual monomer levels of denture base resins, and concluded that when terminal boils was used, the levels of residual monomer were markedly decreased. These authors also cited that the rate of heat application and the thickness of the denture base polymers are influencing factors. Furthermore, these investigations have indicated that in addition to obtaining minimal levels of unpolymerized monomer, denture base resins must be porosity free and therefore an appropriate polymerization cycle is essential to prevent high exothermic reactions. The greater advantage of microwave heating over conventional heat is that temperature rises fast. However, the important factor for consideration is the careful control of the temperature during polymerization processing. De Clerck9 (1987) reported that microwaves do not automatically heat the monomer to the correct temperature of 100.8°C, which can be easily surpassed during polymerization using microwave energy. Therefore, this temperature must be monitored and controlled accurately, and the timing must be correct9. This author observed external porosity when the acrylic resin specimens have absorbed too much energy in the beginning of the polymerization, and internal porosity when too much energy was applied at the end of polymerization using microwave energy. Reitz, et al.17 (1985) and Alkhatib, et al.2 (1990) also noted that the porosity in thick specimens polymerized by microwave energy could be reduced by a longer polymerization time at a lower wattage. Lai, et al.15 (2004) established the time and temperature required for the complete conversion of monomer to polymer, and compared physical and mechanical properties of microwave- and water bath-polymerized acrylic resin specimens. The specimens were polymerized at different times and wattages. The higher power applied to the system, the more the resin temperatures rises, the faster the benzoyl peroxide decomposes, and more rapid is the polymerization reaction. The flexural strength of the specimens polymerized by microwave energy showed strength of 89-92% of water bath polymerized ones. They concluded that microwave energy can effectively polymerize denture base polymer, and has a potential for saving time in processing dentures. However, it has been stated that the choice of a suitable power and polymerization time is important in order to reduce porosity to a minimum level. The aim of this study was to compare the flexural strength of a denture base resin polymerized by various microwave cycles to a conventional heat-polymerized and a autopolymerizing acrylic resin, based on the hypothesis that microwave-polymerized denture base resins exhibit flexural strength in the same range as other resins.

MATERIAL AND METHODS

Five protocols (cycles) were used to polymerize the acrylic resins (Table 1). Clear acrylic resins were chosen in order to identify more easily whether specimens were free of porosity. Cycles A and B were based on works published elsewhere4,5,7,18,23. It has been shown that using a longer cycle at a lower-wattage may decrease porosity significantly 18,23.
TABLE 1

Acrylic resins and polymerization cycles used in this study

MaterialLot numberManufacturerPolymerization cycle
Onda-Cryl (clear microwave-polymerized acrylic resin)404050Artigos Odontológicos Clássico Ltd, São Paulo, SP, BrazilA: Microwave oven: 500 W for 3 min
Onda-Cryl 404050Artigos Odontológicos Clássico LtdB: Microwave oven: 90 W for 13 min + 500 W for 90 sec
Onda-Cryl 404050Artigos Odontológicos Clássico LtdC: Microwave oven: 320 W for 3 min + 0 W for 4 min + 720 W for 3 min *
Clássico (clear conventional heatpolymerized acrylic resin)404050Artigos Odontológicos Clássico LtdT: Conventional water bath: 74°C for 9 h
Jet (clear autopolymerizing acrylic resin)404050Artigos Odontológicos Clássico LtdQ: Press chamber: 50°C for 15 min at 2 bar

Cycle recommended by Onda-Cryl manufacturer.

Cycle recommended by Onda-Cryl manufacturer. The denture resin specimens to flexural strength analysis were prepared by partially investing metal patterns in the conventional metal flasks for cycles T and Q and in the fiber-glass-reinforced plastic flasks for microwave polymerization cycles (A, B and C). To facilitate removal from the flask, the master patterns were individually invested in high-viscosity silicone (Zetalabor, Zhermack S.p.A., Badia Polesine, Rovigo, Italy) and were then further supported by dental stone (Herodent, Vigodent S/A Ind. Com., Rio de Janeiro, RJ, Brazil) within the flasks. After the invested material had set, the flasks were separated, and the master pattern was removed from the silicone mold. Each acrylic resin was mixed according to the manufacturer's recommendations. The resin was then packed and polymerized according to the cycles listed in Table 1. T and Q specimens were processed, respectively, in an automatic polymerization tank (Termotron P-100, Termotron Equipamentos, Piracicaba, SP, Brazil) and in a press chamber (Termo Press, Promeco Ind Eletro Mecânica Ltd, São Paulo, SP, Brazil). For the microwave polymerization method, a domestic microwave oven with a rotating table was used (Continental AW-30, Bosh Eletrodomésticos, Manaus, AM, Brazil). Ten specimens from each cycle were prepared by investing metal patterns with dimensions of 67 × 12 × 5.3 mm. After processing, the resin specimens were polished in a polishing machine (Metaserv 2000, Buehler, UK Ltd., Coventry, England) to a final dimension of 65 × 10 × 3.3 mm, according to the International Organization for Standardization (ISO/FDIS 1567)13. All surfaces of the specimens were finished with 280 and 320-grit wet-dry sandpaper (Norton, Saint-Gobain Abrasivos Ltda, Vinhedo, SP, Brazil) followed by 400 and 600-grit sandpaper. A micrometer was used to record precise specimen measurements. All specimens were stored in distilled water at 37°C for 50 ± 2 hours before testing13. The flexural strength of the five cycle groups were measured using a three-point bending test in a material test system machine (Model 810, MTS System Corp, Edden Praire, Minnesota, USA) at a crosshead speed of 5 mm/min. The flexural strength (TS) was calculated using the formula: TS = 3WL / 2 bd2, where W is the maximum load before fracture, L is the distance between supports (50 mm), b is the specimen width and d is the specimen thickness. Statistical analyses were completed using a one-way analysis of variance (ANOVA) and Tukey's test for post-hoc comparisons. All analyses were performed at a 95% level of confidence. Data were analyzed with SPSS for Windows software (version 12.0.0, Chicago, IL, USA).

RESULTS

Flexural strength means and standard deviation for the cycles are listed in Table 2. There was a significant difference between the three polymerization methods (microwave, conventional water bath and autopolymerizing method), with cycle T exhibiting the lowest value (Table 2). Tukey's test showed a significantly higher flexural strength for microwave-polymerized denture resin, regardless of the polymerization cycle, and there were no differences among any of these groups.
TABLE 2

Means and standard deviations for flexural strength tests (MPa)

Cycle
ABCTQ
106.97a (±5.31)107.57a (±3.99)109.63a (±5.19)84.40b (±1.68)92.84c (±4.73)

Different letters indicate statistically significant difference at 5%.

Different letters indicate statistically significant difference at 5%.

DISCUSSION

Flexural failure of denture base resins is considered the primary mode of clinical failure6. The flexural three-point bending test is useful in comparing denture base materials as it simulates the type of stress that is applied to the denture during mastication25. This study compared the flexural strength of a microwave-polymerized denture base resin (Onda-Cryl) with a conventional heat-polymerized (Clássico) and an autopolymerizing acrylic resin (Jet). Based on the results, the hypothesis that microwave-polymerized denture resin specimens exhibit flexural strength in the same range as that of heat- and autopolymerizing resins was not accepted. The results showed higher flexural strength for Onda-Cryl, regardless of the polymerization cycle. Clássico denture base resin demonstrated the lowest value of flexural strength (84.4 MPa), indicating its inferior strength and low resistance to fracture. These findings are consistent with previous studies2,3,21 that found a statistically higher flexural strength for microwave-processed denture resins. In spite of these results, the flexural strength values for the heat-polymerized resin were in accordance with those found by other authors2. For both autopolymerizing and heat-polymerized acrylic resins, the level of residual monomer in the resin and the mechanical properties are closely related to the polymerization conditions11,12,14. According to Harrison and Huggett12 (1992) the long water bath cycles without terminal boil show levels of residual monomer approximately 3 times greater than when a terminal boil is used. The residual monomer could affect the flexural strength because of a plasticizing effect, which effectively reduces interchange forces14. Consequently, deformation would occur more easily under load. The terminal boil was not used in the water bath cycle (T). It could explain the results found with heat-polymerized denture base resin. The heat-polymerized specimens also showed the lowest strength values, even though autopolymerizing resin. The resin specimens of that have been polymerized for a long period in water may absorb water continuously20, and it could act as a plasticizer, reducing the glass transition temperature (Tg) and the evaluated mechanical property. It might have happened with Clássico denture base resin. The autopolymerizing acrylic resin was polymerized under pressure and at 50°C. It could have improved the fracture strength of Jet acrylic resin. Vallittu, et al.22 (1998) demonstrated that the increase of the polymerization temperature for autopolymerizing resins from 30°C to 60°C, decreased the residual monomer content of the polymer from an average of 4.6 wt% to 3.3 wt%. Ogawa, et al.16 (2000) found that the transverse strength of autopolymerizing resin increased with an increase in water temperature, and concluded the polymerization of the autopolymerizing resin in hot water greatly improves its mechanical properties. Heat may have activated the chemical reaction between the monomer and polymer components of the resin and produces more complete polymerization. This mechanism may explain why hot water conditions improved the mechanical properties of the autopolymerizing acrylic resin. This study has also shown that microwave energy can efficiently polymerize denture base polymer. The results of flexural strength indicated that the evaluated microwave-polymerized resin can be polymerized by cycles A, B and C without strength impairment. Even though there were no significant differences among microwave cycles, cycle A produced the lowest flexural strength values. The specimens polymerized on that cycle absorbed more energy in the beginning of the reaction, and then there was a rapid rise in the resin temperature9,15. It could lead to the formation of porosities, and decreased the flexural strength values. Lai, et al.15 (2004) demonstrated the effectiveness of denture base resin polymerization by microwave energy. They suggested 7, 10, and 15 min to polymerize acrylic resins at 240, 160 and 80 W, respectively. Then, the flask should be turned over, and polymerized for additional 2 minutes at 560 W to complete polymerization. In the same way of the present study, they did not find any significant difference among specimens polymerized by any of the microwave cycles. Although it had been observed, they found that the acrylic resin blocks polymerized at 240 W seemed to be superior to other microwave-polymerized blocks because of their little porosity and sufficiently polymerized state. This study involved a limited analysis of a mechanical property for only one denture base resin polymerized by microwave energy. Further research should be conducted to compare different microwave ovens, other denture base resins, and how they could affect other physical and mechanical properties of these materials. To overcome the limitations of in vitro tests, denture base resins should be evaluated intraorally. The clinical implication of this study is that the polymerization of denture base resin using microwave energy may have a positive effect on the strength and longevity of complete dentures. Also, microwave energy has a potential for saving a great amount of time in processing dentures.

CONCLUSIONS

Within the limitations of this in vitro study, the results suggested that the microwave-processed specimens showed a significantly higher flexural strength than the other ones. The flexural strength means for the specimens polymerized by conventional water bath (T) were comparable to those of the autopolymerizing resin specimens (Q). The microwave-cycles (A, B and C) can be used without compromising damages to the acrylic resin strength. However, it has been stated that the choice for a suitable power and polymerization time is important in order to reduce porosity to a minimum level.
  22 in total

1.  Changes in occlusal vertical dimension in microwave processing of complete dentures.

Authors:  Débora Barros Barbosa; Marco Antonio Compagnoni; Cláudio Rodrigues Leles
Journal:  Braz Dent J       Date:  2002

2.  Flexural strength of rebased denture polymers.

Authors:  N Archadian; F Kawano; T Ohguri; T Ichikawa; N Matsumoto
Journal:  J Oral Rehabil       Date:  2000-08       Impact factor: 3.837

3.  Evaluation of porosity in microwave-processed acrylic resin using a photographic method.

Authors:  Stavros Yannikakis; Alcibiades Zissis; Gregory Polyzois; Andreas Andreopoulos
Journal:  J Prosthet Dent       Date:  2002-06       Impact factor: 3.426

4.  Mechanical properties of new denture resins polymerized by visible light, heat, and microwave energy.

Authors:  L T Smith; J M Powers; D Ladd
Journal:  Int J Prosthodont       Date:  1992 Jul-Aug       Impact factor: 1.681

5.  Effect of the curing cycle on some properties of a polymethylmethacrylate denture base material.

Authors:  R G Jagger
Journal:  J Oral Rehabil       Date:  1978-04       Impact factor: 3.837

6.  The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption.

Authors:  A Doğan; B Bek; N N Cevik; A Usanmaz
Journal:  J Dent       Date:  1995-10       Impact factor: 4.379

7.  Effect of microwave irradiation on the flexural strength and residual monomer levels of an acrylic resin repair material.

Authors:  N Yunus; A Harrison; R Huggett
Journal:  J Oral Rehabil       Date:  1994-11       Impact factor: 3.837

8.  The transverse strength of acrylic resin strips and of repaired acrylic samples.

Authors:  R Grajower; J Goultschin
Journal:  J Oral Rehabil       Date:  1984-05       Impact factor: 3.837

9.  Some flexural properties of a nylon denture base polymer.

Authors:  N Yunus; A A Rashid; L L Azmi; M I Abu-Hassan
Journal:  J Oral Rehabil       Date:  2005-01       Impact factor: 3.837

10.  Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers.

Authors:  A Harrison; R Huggett
Journal:  J Dent       Date:  1992-12       Impact factor: 4.379

View more
  16 in total

1.  Effect of Denture Cleansers on Surface Roughness and Flexural Strength of Heat Cure Denture Base Resin-An In vitro Study.

Authors:  Prabal Sharma; Sandeep Garg; Nidhi Mangtani Kalra
Journal:  J Clin Diagn Res       Date:  2017-08-01

2.  Effect of incorporation of 2-tert-butylaminoethyl methacrylate on flexural strength of a denture base acrylic resin.

Authors:  André Gustavo Paleari; Juliê Marra; Ana Carolina Pero; Larissa Santana Rodriguez; Adhemar Ruvolo-Filho; Marco Antonio Compagnoni
Journal:  J Appl Oral Sci       Date:  2011 May-Jun       Impact factor: 2.698

3.  Flexural strength of acrylic resin denture bases processed by two different methods.

Authors:  Jafar Gharechahi; Nafiseh Asadzadeh; Foad Shahabian; Maryam Gharechahi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-09-17

4.  Effect of sodium hypochlorite and peracetic acid on the surface roughness of acrylic resin polymerized by heated water for short and long cycles.

Authors:  Felipe Sczepanski; Claudia Roberta Brunnquell Sczepanski; Sandrine Bittencourt Berger; Rafael Leonardo Xediek Consani; Alcides Gonini-Júnior; Ricardo Danil Guiraldo
Journal:  Eur J Dent       Date:  2014-10

5.  Effects of thermocycling and various drinks on the color stability of heat-polymerized acrylic resin.

Authors:  Pinar Altinci; Pinar Durkaya
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

6.  Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate.

Authors:  Serhat Emre Ozkir; Burak Yilmaz; Server Mutluay Unal; Ahmet Culhaoglu; Isin Kurkcuoglu
Journal:  Eur J Dent       Date:  2018 Jan-Mar

7.  Effect of Water Storage on the Flexural Strength of Heat-cured Denture Base Resin Reinforced with Stick (s) Glass Fibers.

Authors:  Ankit Galav; Suryakant C Deogade; Sneha Mantri; K Sumathi; Sneha Galav
Journal:  Contemp Clin Dent       Date:  2017 Apr-Jun

8.  Effect of comonomer of methacrylic acid on flexural strength and adhesion of Staphylococcus aureus to heat polymerized poly (methyl methacrylate) resin: An in vitro study.

Authors:  Lokendra Gupta; I N Aparna; Sujatha Bhat; Kishore Ginjupalli
Journal:  J Indian Prosthodont Soc       Date:  2017 Apr-Jun

9.  Influence of incorporation of fluoroalkyl methacrylates on roughness and flexural strength of a denture base acrylic resin.

Authors:  Tatiana Ramirez Cunha; Romulo Rocha Regis; Marília Rodrigues Bonatti; Raphael Freitas de Souza
Journal:  J Appl Oral Sci       Date:  2009 Mar-Apr       Impact factor: 2.698

10.  Comparison of the flexural strength of polymethyl methacrylate resin reinforced with multiwalled carbon nanotubes and processed by conventional water bath technique and microwave polymerization.

Authors:  Surabhi Somkuwar; Sunil Kumar Mishra; Benaiffer Agrawal; Rupali Choure
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.