Literature DB >> 15634304

Some flexural properties of a nylon denture base polymer.

N Yunus1, A A Rashid, L L Azmi, M I Abu-Hassan.   

Abstract

Nylon denture base material could be a useful alternative to poly (methyl methacrylate) (PMMA) in special circumstances such as patient allergy to the monomer. The aim of this study was to evaluate the flexural properties of a nylon denture base material (Lucitone FRS), a conventional compression-moulded heat-polymerized (Meliodent), a compression-moulded microwave-polymerized (Acron MC) and an injection-moulded microwave-polymerized (Lucitone 199) PMMA polymers. The effect of aldehyde-free, oxygen releasing disinfectant solution (Perform) on these properties was also investigated. The flexural modulus and the flexural strength were assessed with a three-point bending test. Specimens were stored in water at a temperature of 37 degrees C for 30 days. For each material, half of the prepared specimens were randomly selected and immersed in the disinfectant 24 h prior to testing. Results were compared statistically at a confidence level of 95%. The result showed that in both the control and disinfected groups, the flexural modulus of nylon was significantly lower than the three PMMA polymers. The flexural strength of nylon was significantly lower than those of Meliodent and Acron MC but was comparable with Lucitone 199. A 24-h immersion in the disinfecting solution increased the rigidity of nylon denture base material.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15634304     DOI: 10.1111/j.1365-2842.2004.01370.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  32 in total

1.  The evaluation of some flexural properties of a denture base resin reinforced with various aesthetic fibers.

Authors:  Orhan Murat Doğan; Giray Bolayir; Selda Keskin; Arife Doğan; Bülent Bek
Journal:  J Mater Sci Mater Med       Date:  2007-12-23       Impact factor: 3.896

2.  Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

Authors:  Hakan Akin; Faik Tugut; Umit Guney; Omer Kirmali; Turker Akar
Journal:  Lasers Med Sci       Date:  2012-03-25       Impact factor: 3.161

3.  Midline Fractures in Single Maxillary Complete Acrylic vs Flexible Dentures.

Authors:  R K Dhiman; Sk Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2011-07-21

4.  Effect of cavity preparation on the flexural strengths of acrylic resin repairs.

Authors:  Safa Salim Elhadiry; Norsiah Yunus; Yusnidar Tajul Ariffin
Journal:  J Appl Oral Sci       Date:  2010-12       Impact factor: 2.698

5.  Flexible denture base material: A viable alternative to conventional acrylic denture base material.

Authors:  J P Singh; R K Dhiman; R P S Bedi; S H Girish
Journal:  Contemp Clin Dent       Date:  2011-10

6.  In vitro comparison of two different materials for the repair of urethan dimethacrylate denture bases.

Authors:  Altug Cilingir; Hakan Bilhan; Onur Geckili; Tonguc Sulun; Ergun Bozdag; Emin Sunbuloglu
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

7.  Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials.

Authors:  Koray Soygun; Giray Bolayir; Ali Boztug
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

8.  Impact of Surface Changes and Microbial Adhesion on Mucosal Surface Finishing of Resin Denture Bases by Shot Blast Polishing Using Viscoelastic Media.

Authors:  Yusuke Yamashita; Yasuhiro Nishi; Mamoru Murakami; Kae Harada; Masahiro Nishimura
Journal:  Materials (Basel)       Date:  2022-03-19       Impact factor: 3.623

9.  Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture.

Authors:  Dae-Eun Jang; Ji-Young Lee; Hyun-Seon Jang; Jang-Jae Lee; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

10.  Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion.

Authors:  Fatih Mehmet Korkmaz; Bora Bagis; Mutlu Ozcan; Rukiye Durkan; Sedanur Turgut; Sabit Melih Ates
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more