Literature DB >> 19083142

Impact of three-dimensional echocardiography in complex congenital heart defect cases: the surgical view.

Alessia Del Pasqua1, Stephen P Sanders, Andrea de Zorzi, Alessandra Toscano, Roberta Iacobelli, Carlo Pierli, Luciano Pasquini, Roberto Di Donato, Gabriele Rinelli.   

Abstract

Other authors have demonstrated the ability of three-dimensional (3D) echocardiography to produce "en face" views of anomalies such as atrioventricular valve disease and atrial and ventricular septal defects. Few data exist about the usefulness of 3D images for more complex congenital heart defects and the surgical impact of this relatively new technology. This study, covering a period of 8 months and including 43 young patients affected by complex congenital heart defects, demonstrated that the routine use of 3D echocardiography is feasible and valuable for some types of cardiac defects. In fact, 3D images have provided more detailed anatomic definition of interrelations between structures in about one-third (15/43) of our cases, yielding new insight into the anatomy analogous to what can be derived from examining a heart specimen. Our surgeons found the 3D images particularly helpful for providing a realistic and almost specimen-like preview of the surgical anatomy that facilitates planning of the surgical program.

Entities:  

Mesh:

Year:  2008        PMID: 19083142     DOI: 10.1007/s00246-008-9348-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  15 in total

1.  Evaluation of mitral valve prolapse using newly developed real-time three-dimensional echocardiographic system with real-time volume rendering.

Authors:  Omer Goktekin; Makoto Matsumura; Ryozo Omoto; Shunei Kyo; Tsuyoshi Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

2.  Images in cardiovascular medicine. Three-dimensional echocardiography in criss-cross heart: could a specimen be better?

Authors:  Alessia Del Pasqua; Stephen Pruett Sanders; Gabriele Rinelli
Journal:  Circulation       Date:  2007-10-23       Impact factor: 29.690

Review 3.  Impact of three-dimensional echocardiography in valvular heart disease.

Authors:  Omid Salehian; Kwan Leung Chan
Journal:  Curr Opin Cardiol       Date:  2005-03       Impact factor: 2.161

4.  Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device; a three-dimensional transoesophageal echocardiographic reconstruction.

Authors:  P Acar; Z Saliba; P Bonhoeffer; Y Aggoun; D Bonnet; D Sidi; J Kachaner
Journal:  Eur Heart J       Date:  2000-04       Impact factor: 29.983

5.  Feasibility and clinical impact of live three-dimensional echocardiography in the management of congenital heart disease.

Authors:  Stefano De Castro; Stefano Caselli; Federica Papetti; Flavia Ventriglia; Arianna Giardina; Elena Cavarretta; Emanuele Di Angelantonio; Andrea Marcantonio; Florinda D Igual Perez; Natesa G Pandian; Bruno Marino; Francesco Fedele
Journal:  Echocardiography       Date:  2006-08       Impact factor: 1.724

6.  Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease.

Authors:  Annemien E van den Bosch; Danielle Robbers-Visser; Boudewijn J Krenning; Marco M Voormolen; Jackie S McGhie; Wim A Helbing; Jolien W Roos-Hesselink; Maarten L Simoons; Folkert J Meijboom
Journal:  J Am Soc Echocardiogr       Date:  2006-01       Impact factor: 5.251

7.  Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study.

Authors:  Tsung O Cheng; Ming-Xing Xie; Xin-Fang Wang; Ying Wang; Qing Lu
Journal:  Am Heart J       Date:  2004-12       Impact factor: 4.749

8.  Left ventricular ejection fraction in children measured by three-dimensional echocardiography using a new transthoracic integrated 3D-probe. A comparison with equilibrium radionuclide angiography.

Authors:  P Acar; C Maunoury; T Antonietti; D Bonnet; D Sidi; J Kachaner
Journal:  Eur Heart J       Date:  1998-10       Impact factor: 29.983

9.  Left atrial and left ventricular function in healthy children and young adults assessed by three dimensional echocardiography.

Authors:  T Poutanen; E Jokinen; H Sairanen; T Tikanoja
Journal:  Heart       Date:  2003-05       Impact factor: 5.994

10.  Cleft mitral valve without ostium primum defect: anatomic data and surgical considerations based on 41 cases.

Authors:  Stella Van Praagh; Diego Porras; Guido Oppido; Tal Geva; Richard Van Praagh
Journal:  Ann Thorac Surg       Date:  2003-06       Impact factor: 4.330

View more
  2 in total

1.  Visualization of patent ductus arteriosus using real-time three-dimensional echocardiogram: Comparative study with 2D echocardiogram and angiography.

Authors:  Alaa Roushdy; Azza El Fiky; Dina Ezz El Din
Journal:  J Saudi Heart Assoc       Date:  2012-02-13

2.  An initial study on left ventricular diastolic function in patients with hypertrophy cardiomyopathy using single-beat, real-time, three-dimensional echocardiography.

Authors:  Bei Zhao; Juan Li; Yong Xu; Hong-Wei Zhu; Guang Zhi
Journal:  J Geriatr Cardiol       Date:  2012-09       Impact factor: 3.327

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.