Literature DB >> 19082641

Reduction of radiation dose during facet joint injection using the new image guidance system SabreSource: a prospective study in 60 patients.

Dirk Proschek1, K Kafchitsas, M A Rauschmann, A A Kurth, T J Vogl, Florian Geiger.   

Abstract

Interventional procedures are associated with high radiation doses for both patients and surgeons. To reduce the risk from ionizing radiation, it is essential to minimize radiation dose. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during facet joint injection in the lumbar spine and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource. A total of 60 patients, treated with a standardized injection therapy of the facet joints L4-L5 or L5-S1, were included in this study. A total of 30 patients were treated by fluoroscopy guidance alone, the following 30 patients were treated using the new SabreSource system. Thus a total of 120 injections to the facet joints were performed. Pain, according to the visual analogue scale (VAS), was documented before and 6 h after the intervention. Radiation dose, time of radiation and the number of exposures needed to place the needle were recorded. No significant differences concerning age (mean age 60.5 years, range 51-69), body mass index (mean BMI 26.2, range 22.2-29.9) and preoperative pain (VAS 7.9, range 6-10) were found between the two groups. There was no difference in pain reduction between the two groups (60 vs. 61.5%; P = 0.001) but the radiation dose was significantly smaller with the new SabreSource system (reduction of radiation dose 32.7%, P = 0.01; reduction of mean entrance surface dose 32.3%, P = 0.01). The SabreSource System significantly reduced the radiation dose received during the injection therapy of the lumbar facet joints. With minimal effort for the setup at the beginning of a session, the system is easy to handle and can be helpful for other injection therapies (e.g. nerve root block therapies).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19082641      PMCID: PMC2899461          DOI: 10.1007/s00586-008-0832-5

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  26 in total

1.  Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

Authors:  Amy Berrington de González; Sarah Darby
Journal:  Lancet       Date:  2004-01-31       Impact factor: 79.321

2.  The current mortality rates of radiologists and other physician specialists: specific causes of death.

Authors:  G M Matanoski; R Seltser; P E Sartwell; E L Diamond; E A Elliott
Journal:  Am J Epidemiol       Date:  1975-03       Impact factor: 4.897

Review 3.  Work-related cancer in the Nordic countries.

Authors:  A Andersen; L Barlow; A Engeland; K Kjaerheim; E Lynge; E Pukkala
Journal:  Scand J Work Environ Health       Date:  1999       Impact factor: 5.024

4.  Logic, truth and language in concepts of pain.

Authors:  H Merskey
Journal:  Qual Life Res       Date:  1994-12       Impact factor: 4.147

5.  Does computer-assisted spine surgery reduce intraoperative radiation doses?

Authors:  Florian T Gebhard; Michael D Kraus; Eugen Schneider; Ulrich C Liener; Lothar Kinzl; Markus Arand
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-01       Impact factor: 3.468

6.  Computerized tomography-guided kryorhizotomy in 76 patients with lumbar facet joint syndrome.

Authors:  Marko Staender; Ulrich Maerz; Jörg Christian Tonn; Ulrich Steude
Journal:  J Neurosurg Spine       Date:  2005-12

7.  Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures.

Authors:  L S Rosenthal; M Mahesh; T J Beck; J P Saul; J M Miller; N Kay; L S Klein; S Huang; P Gillette; E Prystowsky; M Carlson; R D Berger; J H Lawrence; P Yong; H Calkins
Journal:  Am J Cardiol       Date:  1998-08-15       Impact factor: 2.778

8.  Facet joint injection and facet nerve block: a randomised comparison in 86 patients with chronic low back pain.

Authors:  Robert Cornelius Marks; Thomas Houston; Terry Thulbourne
Journal:  Pain       Date:  1992-06       Impact factor: 6.961

Review 9.  Cancer risks among radiologists and radiologic technologists: review of epidemiologic studies.

Authors:  Shinji Yoshinaga; Kiyohiko Mabuchi; Alice J Sigurdson; Michele Morin Doody; Elaine Ron
Journal:  Radiology       Date:  2004-09-16       Impact factor: 11.105

Review 10.  Assessment of adult cancer pain: shortcomings of current methods.

Authors:  Michèle Deschamps; Pierre R Band; Andrew J Coldman
Journal:  Pain       Date:  1988-02       Impact factor: 6.961

View more
  3 in total

1.  Health policy: reducing radiation exposure time for ureteroscopic procedures.

Authors:  Petrisor Geavlete; Razvan Multescu; Bogdan Geavlete
Journal:  Nat Rev Urol       Date:  2011-08-16       Impact factor: 14.432

2.  A novel navigation system to guide metallic foreign body extraction.

Authors:  Bin He; Chao Xu; Yingdelong Mao; Jingwen Mao; Liping Shen; Hao Wei; Fei Wang; Shuogui Xu
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-27       Impact factor: 2.924

3.  Intervention Planning Using a Laser Navigation System for CT-Guided Interventions: A Phantom and Patient Study.

Authors:  Tatjana Gruber-Rouh; Clara Lee; Jan Bolck; Nagy N N Naguib; Boris Schulz; Katrin Eichler; Rene Aschenbach; Julian L Wichmann; Thomas J Vogl; Stephan Zangos
Journal:  Korean J Radiol       Date:  2015-07-01       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.