Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.

Alexandre Campos Montenegro1, Aldir Nascimento Machado, Cresus Vinicius Depes Gouvêa.   

Abstract

PURPOSE: The aim of this in vitro study was to evaluate the tensile strength of titanium cylinders cemented on stainless steel abutment mock-ups by the Cerazone system. METHODS AND MATERIALS: Four types of cements were used: glass ionomer, Fuji I (GC); zinc phosphate, Cimento LS (Vigodent); zinc oxide without eugenol, Rely x Temp NE (3M ESPE); and resin cement, Rely x ARC (3M ESPE). Four experimental groups were formed, each composed of 5 test specimens. Each test specimen consisted of a set of 1 cylinder and 1 stainless steel abutment mock-up. All cements tested were manipulated in accordance with manufacturers' instructions. A static load of 5 Newtons (N) for 2 minutes was used to standardize the procedure. The tensile tests were performed by a mechanical universal testing machine (EMIC DL500MF) at a crosshead speed of 0.5 mm/min.
RESULTS: The highest bonding values resulting from the experiment were obtained by Cimento LS (21.86 MPa mean), followed by the resin cement Rely x ARC (12.95 MPa mean), Fuji I (6.89 MPa mean), and Rely x Temp NE (4.71 MPa mean). The results were subjected to analysis of variance (ANOVA) and the Student's t test.
CONCLUSION: The cements differed amongst them as regards tensile strength, with the highest bonding levels recorded with zinc phosphate (Cimento LS) and the lowest with the zinc oxide without eugenol (Rely x Temp NE).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19077583     DOI: 10.1097/ID.0b013e31818c4947

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  4 in total

1.  The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.

Authors:  S Varalakshmi Reddy; M Sushender Reddy; C Rajaneesh Reddy; Padmaja Pithani; Santosh Kumar R; Ganesh Kulkarni
Journal:  J Clin Diagn Res       Date:  2015-03-01

2.  Retention of Implant Supported Metal Crowns Cemented with Different Luting Agents: A Comparative Invitro Study.

Authors:  Roohi Kapoor; Kavipal Singh; Simrat Kaur; Aman Arora
Journal:  J Clin Diagn Res       Date:  2016-04-01

3.  Retentiveness of implant-supported metal copings using different luting agents.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Maziar Ebrahimi; Ghazal Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-01

4.  Application of Semipermanent Cements and Conventional Cement with Modified Cementing Technique in Dental Implantology.

Authors:  Valentina Veselinović; Saša Marin; Zoran Tatić; Nataša Trtić; Olivera Dolić; Tijana Adamović; Radmila Arbutina; Miodrag Šćepanović; Aleksandar Todorović
Journal:  Acta Stomatol Croat       Date:  2021-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.