Jian-Lin Wu1, Ng Pak Lam, Dieter Martens, Antonius Kettrup, Zongwei Cai.
Abstract
Triclosan in the waste, river and sea water samples collected in Hong Kong was analyzed by using gas chromatography-ion trap mass spectrometry method. (13)C(12)-triclosan was used as internal standard for the quantitative analysis. Water samples were prepared and cleaned-up by using a C(18) solid-phase extraction cartridge. The recoveries of triclosan in spiked coastal water at three different concentrations ranged from 83 to 110%. The method detection limit was 0.25 ng/L for triclosan in 1-L water and the relative standard deviations and relative error were less than 11.0 and 12.3%, respectively (n=3). The method was successfully applied to analyze water samples collected from rivers, coastal water bodies and wastewater treatment plants at ng/L levels.Entities:
Year: 2007 PMID: 19071811 DOI: 10.1016/j.talanta.2007.03.024
Source DB: PubMed Journal: Talanta ISSN: 0039-9140 Impact factor: 6.057