Literature DB >> 19071661

Multielement determination of trace metals in seawater by ICP-MS with aid of down-sized chelating resin-packed minicolumn for preconcentration.

Dwinna Rahmi1, Yanbei Zhu, Eiji Fujimori, Tomonari Umemura, Hiroki Haraguchi.   

Abstract

The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400mesh), with which trace metals in 50mL of original seawater sample were concentrated into 0.50mL of 2M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1M ammonium acetate for elimination of matrix elements, and the amount of 2M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.

Entities:  

Year:  2007        PMID: 19071661     DOI: 10.1016/j.talanta.2006.11.023

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  10 in total

1.  Determination of cobalt, nickel and iron at trace level in natural water samples by in-column chelation-reversed phase high-performance liquid chromatography.

Authors:  Aysen Hol; Umit Divrikli; Latif Elci
Journal:  Environ Monit Assess       Date:  2011-06-24       Impact factor: 2.513

2.  Magnetite nanoparticles with aminomethylenephosphonic groups: synthesis, characterization and uptake of europium(III) ions from aqueous media.

Authors:  Liudmyla Kostenko; Natalia Kobylinska; Sergey Khainakov; Santiago Garcia Granda
Journal:  Mikrochim Acta       Date:  2019-06-27       Impact factor: 5.833

3.  Influence of weight on the content of trace metals in tissues of Mytilus galloprovincialis (Lamarck, 1819): a forecast model.

Authors:  Marcelo Enrique Conti; Marta Iacobucci; Gaetano Cecchetti; Alessandro Alimonti
Journal:  Environ Monit Assess       Date:  2007-08-18       Impact factor: 2.513

4.  MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION TO ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP�MS).

Authors:  Fahmida Zereen; Vedat Yilmaz; Zikri Arslan
Journal:  Anal Lett       Date:  2014       Impact factor: 2.329

Review 5.  Opportunities and challenges for the application of post-consumer plastic waste pyrolysis oils as steam cracker feedstocks: To decontaminate or not to decontaminate?

Authors:  Marvin Kusenberg; Andreas Eschenbacher; Marko R Djokic; Azd Zayoud; Kim Ragaert; Steven De Meester; Kevin M Van Geem
Journal:  Waste Manag       Date:  2021-12-03       Impact factor: 7.145

6.  Development of a Simplified Radiation-Induced Emulsion Graft Polymerization Method and Its Application to the Fabrication of a Heavy Metal Adsorbent.

Authors:  Masaaki Omichi; Yuji Ueki; Noriaki Seko; Yasunari Maekawa
Journal:  Polymers (Basel)       Date:  2019-08-20       Impact factor: 4.329

7.  Development of a fully automatic separation system coupled with online ICP-MS for measuring rare earth elements in seawater.

Authors:  Haitao Li; Rui Tong; Wei Guo; Quanhui Xu; Danyang Tao; Yang Lai; Lanlan Jin; Shenghong Hu
Journal:  RSC Adv       Date:  2022-08-24       Impact factor: 4.036

8.  Trace elements determination in seawater by ICP-MS with on-line pre-concentration on a Chelex-100 column using a 'standard' instrument setup.

Authors:  Jens Søndergaard; Gert Asmund; Martin M Larsen
Journal:  MethodsX       Date:  2015-06-18

9.  State of the art in the determination of trace elements in seawater: a worldwide proficiency test.

Authors:  Pieter Dehouck; Fernando Cordeiro; James Snell; Beatriz de la Calle
Journal:  Anal Bioanal Chem       Date:  2016-02-17       Impact factor: 4.142

10.  Detection and Separation of Inorganic Cations in Natural, Potable, and Wastewater Samples Using Capillary Zone Electrophoresis with Indirect UV Detection.

Authors:  Lara Varden; Fadi Bou-Abdallah
Journal:  Am J Analyt Chem       Date:  2017-01