Literature DB >> 21701886

Determination of cobalt, nickel and iron at trace level in natural water samples by in-column chelation-reversed phase high-performance liquid chromatography.

Aysen Hol1, Umit Divrikli, Latif Elci.   

Abstract

This paper reports the utilization of 4-(2-pyridylazo) resorcinol (PAR) as a chelating reagent for in-column derivatization and the determination of trace Co, Fe, and Ni ions by reversed-phase high-performance liquid chromatography with photodiode array detector. A good separation of Co, Fe, and Ni chelates were achieved by using an Inertsil ODS-3 column and a mobile phase, consisted of methanol-THF-water mixture (50:5:45) containing ammonium acetate buffer (pH 5.0) and PAR. After full optimization, good repeatability of retention times (relative standard deviation (RSD) < 0.05%) and peak areas (RSD < 1.7%) was achieved as well as a good linearity (r (2) > 0.9991). The detection limits (S/N = 3), expressed as micrograms per liter, were 0.50 (Co), 9.07 (Fe), and 2.00 (Ni). The applicability and the accuracy of the developed method were estimated by the analysis of spiked water samples and certified reference material BCR 715 wastewater-SRM.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21701886     DOI: 10.1007/s10661-011-2201-9

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  19 in total

1.  Determination of cadmium, zinc, nickel and cobalt in tobacco by reversed-phase high-performance liquid chromatography with 2-(8-quinolylazo)-4,5-diphenylimidazole as a chelating reagent.

Authors:  Chengjie Zhang; Jun'ichiro Miura; Yukio Nagaosa
Journal:  Anal Sci       Date:  2005-09       Impact factor: 2.081

2.  Forensic investigation of brick stones using instrumental neutron activation analysis (INAA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF).

Authors:  Nicole Scheid; Stefan Becker; Marc Dücking; Gabriele Hampel; Jens Volker Kratz; Peter Watzke; Peter Weis; Stephan Zauner
Journal:  Appl Radiat Isot       Date:  2009-05-27       Impact factor: 1.513

3.  Evaluation of alternate lines of Fe for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry.

Authors:  Jorge Luiz Raposo; Silvana Ruella de Oliveira; Naíse Mary Caldas; José Anchieta Gomes Neto
Journal:  Anal Chim Acta       Date:  2008-08-27       Impact factor: 6.558

4.  Separation and determination of trace amounts of aluminium(III), vanadium(V), iron(III), copper(II) and nickel(II) with CALKS and PAR by RP-HPLC.

Authors:  Jingdong Peng; Shaopu Liu; Chuanyue Deng
Journal:  Anal Sci       Date:  2005-03       Impact factor: 2.081

5.  Fluorimetric determination of magnesium and aluminum via complexation with oxine in high-performance liquid chromatography.

Authors:  T Takeuchi; S Inoue; M Yamamoto; M Tsuji; T Miwa
Journal:  J Chromatogr A       Date:  2001-03-02       Impact factor: 4.759

6.  Determination of lead, cadmium and mercury in microwave-digested foodstuffs by RP-HPLC with an on-line enrichment technique.

Authors:  Zhangjie Huang; Guangyu Yang; Qiufen Hu; Jiayuan Yin
Journal:  Anal Sci       Date:  2003-02       Impact factor: 2.081

7.  The use of 3-(2-pyridyl)-5,6-diphenyl-1,2,4-triazine as a precolumn derivatizing reagent in HPLC determination for Fe(II) in natural samples.

Authors:  Weihuang Zhu; Fengchang Wu; Jian Zheng; Congqiang Liu
Journal:  Anal Sci       Date:  2007-11       Impact factor: 2.081

8.  A new method for simultaneous determination of Co(II), Ni(II) and Pd(II) as morpholine-4-carbodithioate complex by SPME-HPLC-UV system.

Authors:  Varinder Kaur; Ashok Kumar Malik
Journal:  Talanta       Date:  2007-04-08       Impact factor: 6.057

9.  A new approach for simultaneous determination of Co(II), Ni(II), Cu(II) and Pd(II) using 2-thiophenaldehyde-3-thiosemicarbazone as reagent by solid phase microextraction-high performance liquid chromatography.

Authors:  Varinder Kaur; Jatinder Singh Aulakh; Ashok Kumar Malik
Journal:  Anal Chim Acta       Date:  2007-09-21       Impact factor: 6.558

10.  Determination of dissolved hexavalent chromium in industrial wastewater effluents by ion chromatography and post-column derivatization with diphenylcarbazide.

Authors:  E J Arar; J D Pfaff
Journal:  J Chromatogr       Date:  1991-06-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.