Literature DB >> 19071600

Solid phase extraction and preconcentration of uranium(VI) and thorium(IV) on Duolite XAD761 prior to their inductively coupled plasma mass spectrometric determination.

Funda Armagan Aydin1, Mustafa Soylak.   

Abstract

A simple and effective method is presented for the separation and preconcentration of thorium(IV) and uranium(VI) by solid phase extraction on Duolite XAD761 adsorption resin. Thorium(IV) and uranium(VI) 9-phenyl-3-fluorone chelates are formed and adsorbed onto the Duolite XAD761. Thorium(IV) and uranium(VI) are quantitatively eluted with 2molL(-1) HCl and determined by inductively coupled plasma-mass spectrometry (ICP-MS). The influences of analytical parameters including pH, amount of reagents, amount of Duolite XAD761 and sample volume, etc. were investigated on the recovery of analyte ions. The interference of a large number of anions and cations has been studied and the optimized conditions developed have been utilized for the trace determination of uranium and thorium. A preconcentration factor of 30 for uranium and thorium was achieved. The relative standard deviation (N=10) was 2.3% for uranium and 4.5% for thorium ions for 10 replicate determinations in the solution containing 0.5mug of uranium and thorium. The three sigma detection limits (N=15) for thorium(IV) and uranium(VI) ions were found to be 4.5 and 6.3ngL(-1), respectively. The developed solid phase extraction method was successively utilized for the determination of traces thorium(IV) and uranium(VI) in environmental samples by ICP-MS.

Entities:  

Year:  2006        PMID: 19071600     DOI: 10.1016/j.talanta.2006.10.013

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid.

Authors:  Shabnam Shahida; Akbar Ali; Muhammad Haleem Khan; Muhammad Mufazzal Saeed
Journal:  Environ Monit Assess       Date:  2012-05-13       Impact factor: 2.513

2.  Floatation-spectrophotometric Determination of Thorium, Using Complex Formation with Eriochrome Cyanine R.

Authors:  Sabah Shiri; Ali Delpisheh; Ali Haeri; Abdolhossein Poornajaf; Tahereh Khezeli; Nadie Badkiu
Journal:  Anal Chem Insights       Date:  2011-01-23

3.  Th(IV) Adsorption onto Oxidized Multi-Walled Carbon Nanotubes in the Presence of Hydroxylated Fullerene and Carboxylated Fullerene.

Authors:  Jing Wang; Peng Liu; Zhan Li; Wei Qi; Yan Lu; Wangsuo Wu
Journal:  Materials (Basel)       Date:  2013-09-17       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.