Literature DB >> 19071417

A novel spectrophotometric method for batch and flow injection determination of cyanide in electroplating wastewater.

Saad S M Hassan1, Mohamed S A Hamza, Ali E Kelany.   

Abstract

A sensitive and highly selective spectrophotometric method is described for the determination of cyanide. It is based on a reaction of cyanide with aquacyanocobyrinic acid heptamethyl ester (ACCbs) reagent (orange color) at pH 9.5 to give dicyanocobester (DCCbs) (violet color). The increase of the absorption bands of the reaction product at 368 and 580nm and the decrease of the reagent band at 353nm are linearly proportional to the cyanide concentration. The method is used in static mode for determining cyanide over the concentration range 0.04-1.20mugml(-1) with a detection limit of 0.02mugml(-1) and for hydrodynamic analysis of 0.4-5.2mugml(-1) cyanide. Application for batch and flow injection monitoring of cyanide in electroplating wastewater samples gives results agree within+/-1.2% with those obtained by the standard potentiometry using the cyanide ion selective electrode. The method is practically free from interferences by PO(4)(3-), NO(3)(-), NO(2)(-), SO(4)(2-), F(-), Cl(-), Br(-), I(-), S(2-) and SCN(-) ions and gives results with average recoveries of 97.6-99.2%. Advantages offered by using ACCbs as a chromogen for cyanide assay are: (i) high selectivity and sensitivity of the coordination site of the reagent towards cyanide ion; (ii) fast reaction, since legation takes place at the axial position of the reagent; (iii) good solubility and stability of the reagent in aqueous solutions over a wide pH range; (iv) high stability of the reagent (ACCbs) and the colored complex product (DCCbs) and (v) possible absorbance measurements at three different wavelengths.

Entities:  

Year:  2006        PMID: 19071417     DOI: 10.1016/j.talanta.2006.06.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  10 in total

Review 1.  Recent developments in cyanide detection: a review.

Authors:  Jian Ma; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2010-06-04       Impact factor: 6.558

2.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

3.  Pyrene-Hydrazone-π···Hole Coupled Turn-on Fluorescent and Naked- Eye Colorimetric Sensor for Cyanide: Role of Homogeneous π-Hole Dispersion in Anion Selectivity.

Authors:  Vanthana Jeyasingh; Kumaresan Murugesan; Sudha Lakshminarayanan; Narayanan Selvapalam; Geetha Das; Lakshminarayanan Piramuthu
Journal:  J Fluoresc       Date:  2021-06-10       Impact factor: 2.217

Review 4.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

5.  Determination of cyanide and nitrate concentrations in drinking, irrigation, and wastewaters.

Authors:  Seyed Reza Mousavi; Mahdi Balali-Mood; Bamdad Riahi-Zanjani; Mahmood Sadeghi
Journal:  J Res Med Sci       Date:  2013-01       Impact factor: 1.852

6.  Determination of cyanide in urine and saliva samples by ion chromatography with pulsed amperometric detection.

Authors:  Ewa Jaszczak; Sylwia Narkowicz; Jacek Namieśnik; Żaneta Polkowska
Journal:  Monatsh Chem       Date:  2017-06-23       Impact factor: 1.451

7.  The Effects of Low-Dose Irradiation on Human Saliva: A Surface-Enhanced Raman Spectroscopy Study.

Authors:  Ioana Maria Colceriu-Șimon; Mihaela Hedeșiu; Valentin Toma; Gabriel Armencea; Alin Moldovan; Gabriela Știufiuc; Bogdan Culic; Viorica Țărmure; Cristian Dinu; Ioana Berindan-Neagoe; Rareș Ionuț Știufiuc; Mihaela Băciuț
Journal:  Diagnostics (Basel)       Date:  2019-08-22

8.  DE Oxidation-Fused Industrial Wastewater Purification Fuzzy Control and Simulation.

Authors:  Ziyi Ma
Journal:  Comput Intell Neurosci       Date:  2022-02-26

Review 9.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

10.  Determination of cyanide in bamboo shoots by microdiffusion combined with ion chromatography-pulsed amperometric detection.

Authors:  Ming Ding; Kailiang Wang
Journal:  R Soc Open Sci       Date:  2018-04-18       Impact factor: 2.963

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.