EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources.

R E P Taylor1, D W O Rogers.   

Abstract

This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate 169Yb brachytherapy source and 14 high dose rate and pulsed dose rate 192Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are provided. In addition to this, separate tallies are made of the dose contributed from primary, single-scattered, and multiply-scattered photons. Separation of dose in this manner allows one to use convolution/superposition methods to calculate the dose surrounding a brachytherapy source accounting for a non-homogeneous medium. The effect of phantom size on TG-43 dosimetry parameters and scattered dose is also investigated for the 192Ir microSelectron v2 HDR source. This paper describes the calculation methods and presents the dose rate constants calculated for each source with the full set of dosimetry data being available online at the Carleton Laboratory for Radiotherapy Physics brachytherapy database (http://www.physics.carleton.ca/clrp/seed_database/).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19070227     DOI: 10.1118/1.2987676

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

2.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

Review 3.  A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.

Authors:  Yousif A M Yousif; Alexander F I Osman; Mohammed A Halato
Journal:  Phys Eng Sci Med       Date:  2021-06-17

4.  Technical Note: Film-based measurement of gold nanoparticle dose enhancement for 192 Ir.

Authors:  Nema Bassiri; Tara Gray; Shaquan David; Devanshi Yogeshkumar Patel; Andrew Locker; Karl Rasmussen; Niko Papanikolaou; Kathryn M Mayer; Neil Kirby
Journal:  Med Phys       Date:  2019-11-19       Impact factor: 4.071

5.  Dosimetric comparison between the microSelectron HDR (192)Ir v2 source and the BEBIG (60)Co source for HDR brachytherapy using the EGSnrc Monte Carlo transport code.

Authors:  M Anwarul Islam; M M Akramuzzaman; G A Zakaria
Journal:  J Med Phys       Date:  2012-10

6.  Using mean dose rate to compare relative dosimetric efficiency with respect to source type and source change schedules for HDR brachytherapy.

Authors:  Stephen D Davis; William Parker; Michael D C Evans
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

7.  A simple model for calculating relative biological effectiveness of X-rays and gamma radiation in cell survival.

Authors:  Oleg N Vassiliev; Christine B Peterson; David R Grosshans; Radhe Mohan
Journal:  Br J Radiol       Date:  2020-06-04       Impact factor: 3.039

8.  Calculation of excess dose to the eye phantom due to a distanced shielding for electron therapy in head and neck cancers.

Authors:  Keyvan Jabbari; Mahnaz Roayaei; Hosein Saberi
Journal:  J Med Signals Sens       Date:  2012-07

9.  A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source.

Authors:  Shih-Ming Hsu; Chin-Hui Wu; Jeng-Hung Lee; Ya-Ju Hsieh; Chun-Yen Yu; Yi-Jen Liao; Li-Cheng Kuo; Ji-An Liang; David Y C Huang
Journal:  PLoS One       Date:  2012-09-05       Impact factor: 3.240

10.  Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

Authors:  Neda Zaker; Mehdi Zehtabian; Sedigheh Sina; Craig Koontz; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.