Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components.

Luca Cristofolini1, Saverio Affatato, Paolo Erani, Domenico Tigani, Marco Viceconti.   

Abstract

Improved wear resistance in total knee replacement (TKR) is a suitable goal. Whereas the use of metal components is well established, mechanical loosening in recently introduced ceramic components are a cause of concern. The scope of this work was to test in vitro whether ceramic TKR femoral components are more prone to mechanical loosening than metal ones. Composite femurs were implanted with commercially available TKR metal components, and with ceramic components having identical shape to the metal ones. Implanted femurs were tested on a knee simulator for up to 5 x 10(-6) cycles. Inducible micromotions and permanent migrations were recorded throughout the test. The cement layers were inspected for signs of damage or fracture. Micromotions and migrations were similar for metal and ceramic components: their magnitude and trend over time indicated that no implant was becoming loose. When there were statistically significant differences, the ceramic components were more stable than the metal ones. When the cement layers were inspected, a few short cracks were observed; most such cracks appeared during the first cycles, while no further damage occurred in the rest of the test. The type of damage found for both the metal and the ceramic components is compatible with well-fixed implants after long-term cycling. Altogether, no remarkable difference was found between the metal and ceramic components. Therefore, this study rejects the hypothesis that ceramic TKR femoral components are more prone to mechanical loosening. Although this study had a limited sample size, it provides novel pre-clinical indications about the potential of ceramic TKR femoral components.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19064322     DOI: 10.1016/j.knee.2008.08.006

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  5 in total

1.  Preliminary In Vitro Wear Assessment of Ceramic Cemented Femoral Components Coupled with Polyethylene Menisci.

Authors:  Saverio Affatato; Paolo Erani; Maurizio Fersini; Vincenzo Contaldi; Anna Rita Terrizzi; Antonio Licciulli
Journal:  Materials (Basel)       Date:  2021-04-22       Impact factor: 3.623

Review 2.  Ceramic Total Knee Arthroplasty: Ready to Go?

Authors:  G Solarino; C Piconi; V De Santis; A Piazzolla; B Moretti
Journal:  Joints       Date:  2017-10-26

3.  The influence of stem length and fixation on initial femoral component stability in revision total knee replacement.

Authors:  N Conlisk; H Gray; P Pankaj; C R Howie
Journal:  Bone Joint Res       Date:  2012-11-01       Impact factor: 5.853

4.  Ceramic femoral components in total knee arthroplasty - two year follow-up results of an international prospective multi-centre study.

Authors:  Philipp Bergschmidt; Rainer Bader; Dirk Ganzer; Christian Hauzeur; Christoph Lohmann; Wolfgang Rüther; Domenico Tigani; Nicola Rani; Fernando Lopez Prats; Claudio Zorzi; Vincenzo Madonna; Stefano Rigotti; Francesco Benazzo; Stefano Marco Paolo Rossi; Guenther Kundt; Hans Rudolf Bloch; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2012-04-20

Review 5.  Migration of the femoral component and clinical outcomes after total knee replacement: a narrative review.

Authors:  R Zinno; S Di Paolo; G Ambrosino; D Alesi; S Zaffagnini; G Barone; L Bragonzoni
Journal:  Musculoskelet Surg       Date:  2020-12-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.