Literature DB >> 19062362

Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness.

S H Kang1, H K Kim, C K Ham, D S Lee, H I Cho.   

Abstract

We evaluated the clinical usefulness (leukocyte distribution classification, morphologic classification, and morphologic flags) of the following four hematology analyzers: CELL-DYN Sapphire (CD-Sapphire) (Abbott Diagnostics, Santa Clara, CA, USA), ADVIA 120 (Bayer Diagnostics, Tarrytown, NY, USA), Beckman Coulter LH 750 (Beckman Coulter, Miami, FL, USA), and Sysmex XE-2100 (TOA Medical Electronics Co., Kobe, Japan). Four hundred thirty samples from patients and 100 samples from healthy individuals were analyzed. For distributional classification, the sensitivity rates of CD-Sapphire, ADVIA 120, LH 750, and XE-2100 were 93.1, 95.9, 94.9, and 94.9%, respectively, and the efficiency rates were 80.7, 81.6, 84.1, and 84.2%, respectively. For morphologic classification, the sensitivity rates of CD-Sapphire, ADVIA 120, LH 750, and XE-2100 were 88.6, 93.2, 77.3, and 94.3%, respectively, and the efficiency rates were 80.9, 73.0, 79.5, and 74.2%, respectively. Comparing the findings in different morphologic flags, XE-2100 showed the highest sensitivity for Blasts flag (90.9%); CD-Sapphire showed the highest sensitivity for Immature granulocytes and/or Left-shift flag (85.5%); ADVIA 120 showed the highest sensitivity for Atypical lymphocytes flag (60.0%); and LH 750 showed the highest sensitivity for Nucleated RBC flag (75.0%). Our results demonstrate that the four analyzers are comparable in overall performance.

Entities:  

Mesh:

Year:  2008        PMID: 19062362

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  10 in total

1.  Validation rules for blood smear revision after automated hematological testing using Mindray CAL-8000.

Authors:  Sabrina Buoro; Tommaso Mecca; Michela Seghezzi; Barbara Manenti; Giovanna Azzarà; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2016-10-06       Impact factor: 2.352

2.  Clinical utility of the neutrophil distribution pattern obtained using the CELL-DYN SAPPHIRE hematology analyzer for the diagnosis of myelodysplastic syndrome.

Authors:  Tohru Inaba; Yoichi Yuki; Soichi Yuasa; Naohisa Fujita; Kazue Yoshitomi; Toshinori Kamisako; Kunio Torii; Toshiharu Okada; Yoshimasa Urasaki; Takanori Ueda; Kaoru Tohyama
Journal:  Int J Hematol       Date:  2011-07-06       Impact factor: 2.490

3.  Development of a nomogram for the estimation of long-term adherence to clozapine therapy using neutrophil fluorescence.

Authors:  W H Man; A Pérez-Pitarch; I Wilting; E R Heerdink; W W van Solinge; A C G Egberts; A D R Huitema
Journal:  Br J Clin Pharmacol       Date:  2018-04-02       Impact factor: 4.335

4.  Detection of Apoptotic Lymphocytes Through Sysmex XN-1000 As a Diagnostic Marker for Mononucleosis Syndrome.

Authors:  Silvia Sale; Addolorata Emanuela Carone; Maurizio Fumi; Ylenia Pancione; Vincenzo Rocco
Journal:  J Clin Lab Anal       Date:  2016-04-19       Impact factor: 2.352

5.  Mean Corpuscular Volume as a Marker for Adherence to Zidovudine-Containing Therapy in HIV-Infected Adults.

Authors:  Joseph O Mugisha; Katherine Donegan; Sarah Fidler; Gita Ramjee; Andrew Hodson; David T Dunn; Kholoud Porter; Pontiano Kaleebu
Journal:  Open AIDS J       Date:  2012-05-31

6.  Impaired bone healing in multitrauma patients is associated with altered leukocyte kinetics after major trauma.

Authors:  Okan W Bastian; Anne Kuijer; Leo Koenderman; Rebecca K Stellato; Wouter W van Solinge; Luke Ph Leenen; Taco J Blokhuis
Journal:  J Inflamm Res       Date:  2016-05-18

7.  Blood film in the era of streaming cells.

Authors:  Diego Villa Clé
Journal:  Rev Bras Hematol Hemoter       Date:  2017-08-23

8.  Association of the neutrophil to lymphocyte ratio and white blood cell count with response to pharmacotherapy in unipolar psychotic depression: An exploratory analysis.

Authors:  Cornelis F Vos; Tom K Birkenhäger; Willem A Nolen; Walter W van den Broek; Marieke J H Coenen; Sophie E Ter Hark; Robbert-Jan Verkes; Joost G E Janzing
Journal:  Brain Behav Immun Health       Date:  2021-08-05

Review 9.  Purpose and criteria for blood smear scan, blood smear examination, and blood smear review.

Authors:  Gene Gulati; Jinming Song; Alina Dulau Florea; Jerald Gong
Journal:  Ann Lab Med       Date:  2012-12-17       Impact factor: 3.464

Review 10.  Biomarkers of hypochromia: the contemporary assessment of iron status and erythropoiesis.

Authors:  Eloísa Urrechaga; Luís Borque; Jesús F Escanero
Journal:  Biomed Res Int       Date:  2013-02-28       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.