Literature DB >> 1906146

Localization of implanted dipoles by magnetoencephalography.

M Balish1, S Sato, P Connaughton, C Kufta.   

Abstract

We attempted to validate the location of sources predicted by magnetoencephalography (MEG) by studying 19 specially designed dipole electrodes implanted in six patients with intractable partial seizures who were undergoing subdural electrode recording. We used a seven-channel magnetometer to measure the magnetic fields produced by passing through the dipoles a 40-microA, 5-msec square-wave pulse followed 40 msec later by a pulse of opposite polarity; 200 pulses were averaged for each magnetometer position. The actual dipole locations were measured from skull radiographs, and we based MEG localization on a spherical head model with the inclusion of volume currents. MEG estimates of the sources were within several centimeters (mean, 1.69 cm) of the measured locations. We conclude that MEG localization was promising.

Entities:  

Mesh:

Year:  1991        PMID: 1906146     DOI: 10.1212/wnl.41.7.1072

Source DB:  PubMed          Journal:  Neurology        ISSN: 0028-3878            Impact factor:   9.910


  9 in total

1.  Monte Carlo simulation studies of EEG and MEG localization accuracy.

Authors:  Arthur K Liu; Anders M Dale; John W Belliveau
Journal:  Hum Brain Mapp       Date:  2002-05       Impact factor: 5.038

2.  Simultaneous EEG and MEG source reconstruction in sparse electromagnetic source imaging.

Authors:  Lei Ding; Han Yuan
Journal:  Hum Brain Mapp       Date:  2011-11-18       Impact factor: 5.038

3.  Fast robust subject-independent magnetoencephalographic source localization using an artificial neural network.

Authors:  Sung Chan Jun; Barak A Pearlmutter
Journal:  Hum Brain Mapp       Date:  2005-01       Impact factor: 5.038

Review 4.  EEG versus MEG localization accuracy: theory and experiment.

Authors:  D Cohen; B N Cuffin
Journal:  Brain Topogr       Date:  1991       Impact factor: 3.020

Review 5.  Magnetoencephalography: clinical application in epilepsy.

Authors:  Robert C Knowlton
Journal:  Curr Neurol Neurosci Rep       Date:  2003-07       Impact factor: 5.081

6.  Clinical applications of magnetoencephalography in epilepsy.

Authors:  Amit Ray; Susan M Bowyer
Journal:  Ann Indian Acad Neurol       Date:  2010-01       Impact factor: 1.383

7.  Precision of dipole localization in a spherical volume conductor: a comparison of referential EEG, magnetoencephalography and scalp current density methods.

Authors:  A M Murro; J R Smith; D W King; Y D Park
Journal:  Brain Topogr       Date:  1995       Impact factor: 3.020

8.  Can magnetoencephalography aid epilepsy surgery?

Authors:  Robert C Knowlton
Journal:  Epilepsy Curr       Date:  2008 Jan-Feb       Impact factor: 7.500

9.  In vivo validation of distributed source solutions for the biomagnetic inverse problem.

Authors:  A A Ioannides; R Muratore; M Balish; S Sato
Journal:  Brain Topogr       Date:  1993       Impact factor: 3.020

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.