Literature DB >> 19060789

Quantification of aortic valve stenosis: head-to-head comparison of 64-slice spiral computed tomography with transesophageal and transthoracic echocardiography and cardiac catheterization.

Alexander Lembcke1, Dietmar E Kivelitz, Adrian C Borges, André Lachnitt, Patrick A Hein, Pascal M Dohmen, Holger Thiele.   

Abstract

OBJECTIVES: We sought to evaluate the accuracy of multislice computed tomography (MSCT) with 64 detector rows for determination of the aortic valve area (AVA) compared with transesophageal and transthoracic echocardiography (TEE and TTE) and cardiac catheterization (CATH).
MATERIALS AND METHODS: MSCT, TEE, TTE, and CATH were performed in 36 patients with aortic valve stenosis. AVA was determined by planimetry on MSCT and TEE and calculated using the continuity equation on Doppler TTE and the Gorlin formula on CATH.
RESULTS: The mean AVA on MSCT (0.88 +/- 0.39 cm2) was not significantly different from TEE (0.94 +/- 0.41 cm2; P > 0.05) but significantly larger than TTE (0.74 +/- 0.28 cm2; P < 0.001) and CATH (0.75 +/- 0.31 cm2; P < 0.001). A good correlation with acceptable limits of agreement was found between MSCT and TTE (r = 0.91, limits +/-0.35 cm2) and between MSCT and CATH (r = 0.91, limits +/-0.32 cm2). An inferior correlation with wider limits of agreement was found between MSCT and TEE (r = 0.82, limits +/-0.48 cm2), but this applied also between TEE and TTE (r = 0.79, limits +/-0.51 cm2) and between TEE and CATH (r = 0.78, limits +/-0.52 cm2).
CONCLUSIONS: AVA determined by MSCT correlated well with TTE and CATH, but a systematic difference must be taken into account when using MSCT findings for therapeutic decision-making. Validation against both TTE and CATH revealed a superior correlation and narrower limits of agreement for MSCT than for TEE suggesting that AVA planimetry with MSCT is more reliable than with TEE.

Entities:  

Mesh:

Year:  2009        PMID: 19060789     DOI: 10.1097/RLI.0b013e31818f769b

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Automatic vs semi-automatic global cardiac function assessment using 64-row CT.

Authors:  J Greupner; E Zimmermann; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

2.  Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography.

Authors:  Linnea Hornbech Larsen; Klaus Fuglsang Kofoed; Helle Gervig Carstensen; Mads Rams Mejdahl; Mads Jønsson Andersen; Jesper Kjaergaard; Olav Wendelboe Nielsen; Lars Køber; Rasmus Møgelvang; Christian Hassager
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-15       Impact factor: 2.357

3.  Quantification of stenotic mitral valve area and diagnostic accuracy of mitral stenosis by dual-source computed tomography in patients with atrial fibrillation: comparison with cardiovascular magnetic resonance and transthoracic echocardiography.

Authors:  Song Soo Kim; Sung Min Ko; Meong Gun Song; Hyun Kun Chee; Jun Suk Kim; Hweung Kon Hwang; Jae-Hwan Lee
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-11       Impact factor: 2.357

4.  Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis.

Authors:  Katarzyna Mizia-Stec; Piotr Pysz; Marek Jasiński; Tomasz Adamczyk; Agnieszka Drzewiecka-Gerber; Artur Chmiel; Michał Krejca; Andrzej Bochenek; Stanisław Woś; Maciej Sosnowski; Zbigniew Gąsior; Maria Trusz-Gluza; Michał Tendera
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

5.  Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography.

Authors:  V Tuncay; N Prakken; P M A van Ooijen; R P J Budde; T Leiner; M Oudkerk
Journal:  Biomed Res Int       Date:  2015-06-29       Impact factor: 3.411

6.  Trends in the utilization of computed tomography and cardiac catheterization among children with congenital heart disease.

Authors:  Justin Cheng-Ta Yang; Ming-Tai Lin; Fu-Shan Jaw; Shyh-Jye Chen; Jou-Kou Wang; Tiffany Ting-Fang Shih; Mei-Hwan Wu; Yiu-Wah Li
Journal:  J Formos Med Assoc       Date:  2014-09-18       Impact factor: 3.282

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.