Literature DB >> 19058684

Quantitative microleakage evaluation of fissure sealants applied with or without a bonding agent: results after four-year water storage in vitro.

Z C Cehreli1, H C Gungor.   

Abstract

PURPOSE: To evaluate the effect of long-term water storage on the microleakage of a fissure sealant applied with or without different bonding agents.
MATERIALS AND METHODS: Extracted human third molars were randomly assigned into 8 groups (n = 24/each). The occlusal surfaces were sealed with a fluoride fissure sealant material (Helioseal F) after one of the following pretreatments: (1) phosphoric acid etching only; (2) phosphoric acid etching + Single Bond; (3) phosphoric acid etching + Prime & Bond NT; (4) Clearfil SE Bond; (5) FL Bond; (6) One Up Bond F; (7) Prompt L-Pop; (8) Mac Bond II. All specimens were thermocycled (1000X), after which half of them (n=96) were stored in distilled water for 48 h (group A), and the remaining half (n=96) for 48 months (group B). The specimens were immersed in 0.5% basic fuchsin solution, sectioned, and digitally photographed. Microleakage was evaluated quantitatively using an open-source image analysis toolkit (ImageJ), and the data were analyzed statistically.
RESULTS: Four-year water storage significantly increased the amount of leakage in all test groups (p < 0.001). In both the absence and presence of water aging, the etch-and-rinse adhesives yielded the lowest microleakage scores (p < 0.001). In the 48-h group, the following ranking was achieved in terms microleakage values: phosphoric acid + Prime &amp; Bond NT = phosphoric acid + Single Bond < Prompt L-Pop = phosphoric acid etching only < FL Bond < Clearfil SE Bond < Mac Bond II = One Up Bond F. In the 48-month group, the ranking changed as follows: phosphoric acid + Prime &amp; Bond NT = phosphoric acid + Single Bond < Prompt L-Pop = FL Bond < Clearfil SE Bond = Mac Bond II = One Up Bond F < phosphoric acid etching only.
CONCLUSION: Long-term water storage significantly increased the microleakage of Helioseal F applied alone and with a bonding agent. Regardless of the storage term, the use of etch-and-rinse adhesives resulted in significantly less microleakage compared to that achieved with self-etching adhesives or acid etching alone. The sealants placed without a prior bonding agent showed the greatest amount of leakage after four years.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19058684

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  11 in total

1.  Integrity testing of a smooth surface resin sealant around orthodontic brackets using a new Fluorescence-aided Identification Technique (FIT).

Authors:  Christian Meller; Timm Schott
Journal:  Angle Orthod       Date:  2018-07-13       Impact factor: 2.079

2.  A comparative study of clinical effectiveness of fissure sealing with and without bonding systems: 3-year results.

Authors:  C Sakkas; L Khomenko; I Trachuk
Journal:  Eur Arch Paediatr Dent       Date:  2013-04-03

3.  Evaluation of different types of enamel conditioning before application of a fissure sealant.

Authors:  Philip Ciucchi; Klaus W Neuhaus; Marta Emerich; Anne Peutzfeldt; Adrian Lussi
Journal:  Lasers Med Sci       Date:  2013-05-01       Impact factor: 3.161

4.  Effectiveness of pit and fissure sealants bonded with different adhesive systems: a prospective randomized controlled trial.

Authors:  Gizem Erbas Unverdi; Stephan Atilla Atac; Zafer Cavit Cehreli
Journal:  Clin Oral Investig       Date:  2016-11-30       Impact factor: 3.573

5.  Effect of Precuring and Postcuring of Total-Etch and Self-Etch Bonding Agents on the Microleakage of Fissure Sealants.

Authors:  Bahman Seraj; Ghasem Meighani; Shabnam Milani; Mostafa Fatemi
Journal:  Front Dent       Date:  2019-12-20

6.  Effect of C-factor and LED Curing Mode on Microleakage of Class V Resin Composite Restorations.

Authors:  Qasem Diefallah Alomari; Kefah Barrieshi-Nusair; Mohammad Ali
Journal:  Eur J Dent       Date:  2011-08

7.  Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth.

Authors:  Mahtab Memarpour; Nasrin Kianimanesh; Bahareh Shayeghi
Journal:  Restor Dent Endod       Date:  2014-05-22

8.  In Vitro Microleakage Comparison of Flowable Nanocomposites and Conventional Materials Used in Pit and Fissure Sealant Therapy.

Authors:  Sara Arastoo; Azam Behbudi; Vahid Rakhshan
Journal:  Front Dent       Date:  2019-01-20

9.  Microleakage of newly developed glass carbomer cement in primary teeth.

Authors:  Sevi Burcak Cehreli; R Ebru Tirali; Zeynep Yalcinkaya; Zafer C Cehreli
Journal:  Eur J Dent       Date:  2013-01

10.  Sealing versus partial caries removal in primary molars: a randomized clinical trial.

Authors:  Daniela Hesse; Clarissa Calil Bonifácio; Fausto Medeiros Mendes; Mariana Minatel Braga; José Carlos Pettorossi Imparato; Daniela Prócida Raggio
Journal:  BMC Oral Health       Date:  2014-05-28       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.