Literature DB >> 19050608

Gastrointestinal microcirculation and cardiopulmonary function during experimentally increased intra-abdominal pressure.

Pia H Olofsson1, Sören Berg, Henrik C Ahn, Lars H Brudin, Tore Vikström, Kenth J M Johansson.   

Abstract

OBJECTIVES: The aim of this study was to assess gastric, intestinal, and renal cortex microcirculation parallel with central hemodynamics and respiratory function during stepwise increase of intra-abdominal pressure (IAP).
DESIGN: Prospective, controlled animal study.
SETTING: Research laboratory, University Hospital.
SUBJECTS: Twenty-six anesthetized and mechanically ventilated pigs.
INTERVENTIONS: Following baseline registrations, CO2 peritoneum was inflated (n = 20) and IAP increased stepwise by 10 mm Hg at 10 mins intervals up to 50 mm Hg and subsequently exsufflated. Control animals (n = 6) were not insufflated with CO2.
MEASUREMENTS AND MAIN RESULTS: The microcirculation of gastric mucosa, small bowel mucosa, small bowel seromuscular layer, colon mucosa, colon seromuscular layer, and renal cortex were selectively studied at all pressure levels and after exsufflation using a four-channel laser Doppler flowmeter (Periflex 5000, Perimed). Central hemodynamic and respiratory function data were registered at each level and after exsufflation. Cardiac output decreased significantly at IAP levels above 10 mm Hg. The microcirculation of gastric mucosa, renal cortex and the seromuscular layer of small bowel and colon was significantly reduced with each increase of IAP. The microcirculation of the small bowel mucosa and colon mucosa was significantly less affected compared with the serosa (p < 0.01).
CONCLUSIONS: Our animal model of low and high IAP by intraperitoneal CO2-insufflation worked well for studies of microcirculation, hemodynamics, and pulmonary function. During stepwise increases of pressure there were marked effects on global hemodynamics, respiratory function, and microcirculation. The results indicate that intestinal mucosal flow, especially small bowel mucosal flow, although reduced, seems better preserved in response to intra-abdominal hypertension caused by CO2-insufflation than other intra-abdominal microvascular beds.

Entities:  

Mesh:

Year:  2009        PMID: 19050608     DOI: 10.1097/CCM.0b013e318192ff51

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  20 in total

1.  Development of an endoluminal intestinal lengthening device using a geometric intestinal attachment approach.

Authors:  Farokh R Demehri; Jennifer J Freeman; Yumi Fukatsu; Jonathan Luntz; Daniel H Teitelbaum
Journal:  Surgery       Date:  2015-05-23       Impact factor: 3.982

2.  How Lichtenstein hernia repair affects abdominal and anal resting pressures: a controlled clinical study.

Authors:  Kemal Peker; Arda Isik; Abdullah Inal; Ismail Demiryilmaz; Ismayil Yilmaz; Mustafa Emiroglu
Journal:  Int J Clin Exp Med       Date:  2014-02-15

3.  Risk factors and outcome of intra-abdominal hypertension in patients with severe acute pancreatitis.

Authors:  Lu Ke; Hai-Bin Ni; Jia-Kui Sun; Zhi-Hui Tong; Wei-Qin Li; Ning Li; Jie-Shou Li
Journal:  World J Surg       Date:  2012-01       Impact factor: 3.352

Review 4.  Mild to moderate intra-abdominal hypertension: Does it matter?

Authors:  Liivi Maddison; Joel Starkopf; Annika Reintam Blaser
Journal:  World J Crit Care Med       Date:  2016-02-04

5.  Intestinal histopathological changes in a porcine model of pneumoperitoneum-induced intra-abdominal hypertension.

Authors:  Ester Párraga Ros; Laura Correa-Martín; Francisco M Sánchez-Margallo; Irma Eugenia Candanosa-Aranda; Manu L N G Malbrain; Robert Wise; Rafael Latorre; Octavio López Albors; Gregorio Castellanos
Journal:  Surg Endosc       Date:  2018-05-17       Impact factor: 4.584

6.  Pretreatment with endothelium-derived nitric oxide synthesis modulators on gastrointestinal microcirculation during NOTES: an experimental study.

Authors:  Pilar Taurà; Aitnitze Ibarzabal; Marina Vendrell; Cedric Adelsdorfer; Alberto Delitala; Borja de Lacy; Ramon Deulofeu; Salvadora Delgado; Antonio M Lacy
Journal:  Surg Endosc       Date:  2016-03-23       Impact factor: 4.584

7.  Original Research: Porcine model for observing changes due to ischemia/reperfusion injury secondary to intra-abdominal endovascular balloon occlusion.

Authors:  Chia-Sheng Chao; Chien-Sung Tsai; Yao-Horng Wang; Yuan-Hao Liu; Jian-Ming Chen; Yee-Phoung Chang; Hsien-Kuo Chin; Shang-Tao Chien; Tai-Ming Lee; Shyh-Chyun Yang
Journal:  Exp Biol Med (Maywood)       Date:  2016-05-22

8.  Creation of pneumoperitoneum: noninvasive monitoring of clinical effects of elevated intraperitoneal pressure for the insertion of the first trocar.

Authors:  Octávio Henrique Mendes Hypólito; João Luiz Moreira Coutinho Azevedo; Fabiana Mara Scarpelli de Lima Alvarenga Caldeira; Otávio Cansanção de Azevedo; Susana Abe Miyahira; Gustavo Peixoto Soares Miguel; Otávio Monteiro Becker; Afonso Cesar Cabral Guedes Machado; Gilberto Pinheiro Nunes Filho; Glícia Cansanção Azevedo
Journal:  Surg Endosc       Date:  2009-12-25       Impact factor: 4.584

9.  The effect of intra-abdominal hypertension incorporating severe acute pancreatitis in a porcine model.

Authors:  Lu Ke; Zhi-hui Tong; Hai-bin Ni; Wei-wei Ding; Jia-kui Sun; Wei-qin Li; Ning Li; Jie-shou Li
Journal:  PLoS One       Date:  2012-03-05       Impact factor: 3.240

10.  Temporal differences in the development of organ dysfunction based on two different approaches to induce experimental intra-abdominal hypertension in swine.

Authors:  Michael Moller; Ulrik K Kjerkegaard; Jens Larsen; Hanne Birke-Sorensen; Lars B Stolle
Journal:  Ann Intensive Care       Date:  2012-07-05       Impact factor: 6.925

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.