Literature DB >> 19050473

Diurnal variation of ocular hysteresis, corneal thickness, and intraocular pressure.

Meixiao Shen1, Jianhua Wang, Jia Qu, Suzhong Xu, Xiaoxing Wang, Haizhen Fang, Fan Lu.   

Abstract

PURPOSE: To investigate, in healthy Asian subjects, the diurnal changes of the corneal biomechanical properties of corneal hysteresis (CH) and its relation to fluctuations of intraocular pressure (IOP) and central corneal thickness (CCT) after sleeping.
METHODS: Forty eyes of 20 healthy Asian volunteers (4 males and 16 females) with a mean age of 19.7 +/- 1.1 years were measured with a modified retinal optical coherence tomography and an ocular response analyzer (ORA). CH, CCT, Goldmann-equivalent intraocular pressure (IOPg), corneal resistance factor (CRF), and corneal compensated intraocular pressure (IOPcc) were obtained. Repeated measurements were conducted on both eyes during a 24-h period, including immediately before and after sleeping.
RESULTS: There were no significant differences in any measured variable between right and left eyes [Repeated measurement analysis of variance (Re-ANOVA), p > 0.05]. Diurnal variations (Re-ANOVA, p = 0.001) of CCT, IOPg, IOPcc, and CRF were found during the 24-h period. Significant increases occurred a few minutes after overnight sleep compared with the baseline values at 10:00 PM before sleep (post hoc tests, p = 0.001). However, there were no differences of CH over time during the study period (Re-ANOVA, p = 0.11). A few minutes after awakening, the increase of CCT was not related to the changes of CH, IOPg, IOPcc, or CRF. However, the increase of CRF was significantly correlated with the changes of IOPg.
CONCLUSION: Diurnal variation of CH was not detectable in healthy Asian eyes. The diurnal fluctuation of IOP appears not to be associated with CH. However, CRF was increased a few minutes after sleeping, a change that was correlated to the changes of IOPg.

Entities:  

Mesh:

Year:  2008        PMID: 19050473     DOI: 10.1097/OPX.0b013e31818e8abe

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  15 in total

1.  Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Authors:  Qi Chen; Jianhua Wang; Aizhu Tao; Meixiao Shen; Shuliang Jiao; Fan Lu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-20       Impact factor: 4.799

2.  Analysis of seasonal changes in residual refraction 1-year after corneal laser refractive surgery: a retrospective study.

Authors:  Michiel H A Luger; Tobias Ewering; Samuel Arba-Mosquera
Journal:  J Optom       Date:  2014-01-24

3.  Micrometer-scale contact lens movements imaged by ultrahigh-resolution optical coherence tomography.

Authors:  Lele Cui; Meixiao Shen; Michael R Wang; Jianhua Wang
Journal:  Am J Ophthalmol       Date:  2011-09-13       Impact factor: 5.258

4.  Characterization of soft contact lens edge fitting using ultra-high resolution and ultra-long scan depth optical coherence tomography.

Authors:  Meixiao Shen; Lele Cui; Colleen Riley; Michael R Wang; Jianhua Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-09       Impact factor: 4.799

5.  Corneal Behavior during Tonometer Measurement during the Water Drinking Test in Eyes with XEN GelStent in Comparison to Non-Implanted Eyes.

Authors:  Agnieszka Jóźwik; Joanna Przeździecka-Dołyk; Ewa Wałek; Magdalena Czerniak; Magdalena Asejczyk
Journal:  J Clin Med       Date:  2022-05-24       Impact factor: 4.964

6.  [Biomechanical condition of the cornea as a new indicator for pathological and structural changes].

Authors:  E Spörl; N Terai; M Haustein; A G Böhm; F Raiskup-Wolf; L E Pillunat
Journal:  Ophthalmologe       Date:  2009-06       Impact factor: 1.059

7.  Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface.

Authors:  Semra Akkaya Turhan; Ebru Toker
Journal:  Clin Ophthalmol       Date:  2015-05-25

8.  Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography.

Authors:  Lele Cui; Ming Li; Meixiao Shen; Fan Lu; Jianhua Wang
Journal:  J Ophthalmol       Date:  2017-06-01       Impact factor: 1.909

9.  Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma.

Authors:  Stuart Keel; Linda Malesic; Siew-Pang Chan
Journal:  Indian J Ophthalmol       Date:  2014-11       Impact factor: 1.848

10.  High intercorneal symmetry in corneal biomechanical metrics.

Authors:  XiaoBo Zheng; FangJun Bao; Brendan Geraghty; JinHai Huang; Ayong Yu; QinMei Wang
Journal:  Eye Vis (Lond)       Date:  2016-03-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.