Literature DB >> 19043767

[Health evaluation of carbon dioxide in indoor air].

.   

Abstract

For over 150 years, carbon dioxide has been an acknowledged indicator of indoor air quality. To estimate the air quality in mechanically ventilated buildings, DIN EN 13779 proposes four different levels of indoor carbon dioxide concentration. However, apart from the early guideline value of 1000 ppm carbon dioxide recommended by Pettenkofer in 1858, there is no actual guideline value for naturally ventilated buildings. Regarding recent intervention studies, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities therefore recommends the following guide values, based on health and hygiene considerations: concentrations of indoor air carbon dioxide below 1000 ppm are regarded as harmless, those between 1000 and 2000 ppm as elevated and those above 2000 ppm as unacceptable. In addition to the recommendations for TVOC values, this further assists in the assessment of indoor air quality.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19043767     DOI: 10.1007/s00103-008-0707-2

Source DB:  PubMed          Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz        ISSN: 1436-9990            Impact factor:   1.513


  6 in total

1.  Air quality in an air ventilated fitness center reopening for pilot study during COVID-19 pandemic lockdown.

Authors:  Eva-Maria Huessler; Anika Hüsing; Markus Vancraeyenest; Karl-Heinz Jöckel; Bernadette Schröder
Journal:  Build Environ       Date:  2022-05-13       Impact factor: 7.093

2.  Carbon dioxide rises beyond acceptable safety levels in children under nose and mouth covering: Results of an experimental measurement study in healthy children.

Authors:  Harald Walach; Helmut Traindl; Juliane Prentice; Ronald Weikl; Andreas Diemer; Anna Kappes; Stefan Hockertz
Journal:  Environ Res       Date:  2022-05-28       Impact factor: 8.431

3.  Experimental Assessment of Carbon Dioxide Content in Inhaled Air With or Without Face Masks in Healthy Children: A Randomized Clinical Trial.

Authors:  Harald Walach; Ronald Weikl; Juliane Prentice; Andreas Diemer; Helmut Traindl; Anna Kappes; Stefan Hockertz
Journal:  JAMA Pediatr       Date:  2021-06-30       Impact factor: 26.796

4.  Distributed LoRa based CO2 monitoring network - A standalone open source system for contagion prevention by controlled ventilation.

Authors:  Yannic Toschke; Janet Lusmoeller; Lars Otte; Johann Schmidt; Svenja Meyer; Alexander Tessmer; Christian Brockmann; Milena Ahuis; Emma Hüer; Christian Kirberger; Dirk Berben
Journal:  HardwareX       Date:  2022-01-10

Review 5.  [Ventilation concepts in schools for the prevention of transmission of highly infectious viruses (SARS-CoV-2) by aerosols in indoor air].

Authors:  Wolfram Birmili; Hans-Christoph Selinka; Heinz-Jörn Moriske; Anja Daniels; Wolfgang Straff
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2021-11-05       Impact factor: 1.513

6.  Indoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities.

Authors:  Alexandre Baudet; Estelle Baurès; Olivier Blanchard; Pierre Le Cann; Jean-Pierre Gangneux; Arnaud Florentin
Journal:  Toxics       Date:  2022-03-12
  6 in total