123I-BMIPP delayed scintigraphic imaging in patients with chronic heart failure.

Keisuke Kida1, Yoshihiro J Akashi, Kihei Yoneyama, Mitsuhiro Shimokawa, Haruki Musha.   

Abstract

OBJECTIVE: The objective of the present study was to clarify the ability of 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) to evaluate the heart-to-mediastinum (H/M) ratio and myocardial global washout rate (WR) in patients with chronic heart failure (CHF).
METHODS: The severity of CHF was evaluated on the basis of the New York Heart Association (NYHA) classification. Twenty patients with CHF (13 with idiopathic dilated cardiomyopathy and 7 with ischemic cardiomyopathy) and 11 age-matched controls underwent myocardial radionuclide imaging. Scintigraphic images were obtained from each participant at the early (30 min following radio-isotope injection) and late (4 h) phases using 123I-BMIPP. The H/M ratio and WR were calculated from planar images. Concentrations of plasma brain natriuretic peptide (BNP) were measured prior to the scintigraphic study.
RESULTS: The 123I-BMIPP uptake of early H/M and global WR did not significantly differ among groups, but uptake of delayed H/M was significantly lower in patients with NYHA class III than in controls (control 2.47 +/- 0.39; class III 1.78 +/- 0.28, P < 0.05). The uptake of delayed H/M and global WR correlated with plasma log BNP in all participants (r = -0.38, P < 0.05; 0.43, P < 0.05, respectively).
CONCLUSIONS: These data suggest that 123I-BMIPP uptake of delayed H/M enhances the image of CHF severity. The myocardial WR of 123I-BMIPP also effectively depicted the severity of CHF.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19039555     DOI: 10.1007/s12149-008-0180-x

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  4 in total

Review 1.  PET and SPECT in cardiovascular molecular imaging.

Authors:  Lawrence W Dobrucki; Albert J Sinusas
Journal:  Nat Rev Cardiol       Date:  2009-11-24       Impact factor: 32.419

2.  Multimodality and nanoparticles in medical imaging.

Authors:  Wen-Yen Huang; Jason J Davis
Journal:  Dalton Trans       Date:  2011-03-14       Impact factor: 4.390

3.  Clinical significance of 123I-BMIPP washout rate in patients with uncertain chronic heart failure.

Authors:  Chihiro Aoshima; Shinichiro Fujimoto; Ayako Kudo; Yuko O Kawaguchi; Kazuhisa Takamura; Yuya Matsue; Takao Kato; Yoshifumi Kawamura; Satoshi Kimura; Yuki Kamo; Yui O Nozaki; Daigo Takahashi; Nobuo Tomizawa; Makoto Hiki; Takatoshi Kasai; Shuko Nojiri; Hideyuki Miyauchi; Ken-Ichi Hirano; Kazunori Shimada; Koji Murakami; Tohru Minamino
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-03-17       Impact factor: 10.057

4.  Relevance of I-BMIPP delayed scintigraphic imaging for patients with angina pectoris - a pilot study.

Authors:  Kohei Koyama; Yoshihiro J Akashi; Keisuke Kida; Kengo Suzuki; Yuki Ishibashi; Haruki Musha; Maciej Banach
Journal:  Arch Med Sci       Date:  2011-07-11       Impact factor: 3.318