Interfractional set-up errors evaluation by daily electronic portal imaging of IMRT in head and neck cancer patients.

Berrin Pehlivan1, Charlotte Pichenot, Marine Castaing, Anne Auperin, Dimitri Lefkopoulos, Rodrigo Arriagada, Jean Bourhis.   

Abstract

INTRODUCTION: Interfractional set-up errors were assessed from daily portal images (PI) registration for head and neck cancer patients. We aimed to evaluate whether a daily PI is worthwhile and we derived the Planning Target Volume (PTV) margins from the estimation of systematic and random errors.
MATERIAL AND METHODS: Twenty patients were treated in supine position with a fixed 5-point mask immobilisation system and head-and-knee supports. DRRs (Digitally Reconstructed Radiograph) were obtained from the planning CT-scan and considered the reference images to be compared with two orthogonal PI by matching bone anatomy landmarks. A total of 567 PI were done. For the set-up errors analysis, we determined the systematic, random, and overall standard deviations (SD), as well as the overall means in three directions (cranio caudal CC, medio lateral ML and anterior posterior AP). PTV-margins were calculated according to three methods. Differences of SD regarding the overall displacements among portals performed every day and each 2, 3, or 4 days were tested.
RESULTS: The systematic set-up errors were less than 1 mm in the three directions whereas the random set-up errors were around 2 mm. PTV margins varied from 3 to 4 mm in the 3 directions. Corrections were significant in the CC direction only, in which the set-up error increased significantly when the scenario of one PI every 3 fractions was adopted.
CONCLUSIONS: It is of practical importance to apply on-line protocols with contouring of the bony landmarks on the PI in order to decrease the systematic mean error in this patient group. This study suggested that a PI in AP and ML directions once a week and every two days in the CC direction would be adequate to overcome the problem of set-up errors.

Entities:  

Mesh:

Year:  2009        PMID: 19031160     DOI: 10.1080/02841860802400610

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  9 in total

1.  A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients.

Authors:  J Cacicedo; J F Perez; R Ortiz de Zarate; O del Hoyo; F Casquero; A Gómez-Iturriaga; A Lasso; E Boveda; P Bilbao
Journal:  Clin Transl Oncol       Date:  2014-07-19       Impact factor: 3.405

2.  Radial displacement of clinical target volume in node negative head and neck cancer.

Authors:  Wan Jeon; Hong-Gyun Wu; Sang Hyuk Song; Jung-In Kim
Journal:  Radiat Oncol J       Date:  2012-03-31

3.  Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins.

Authors:  Volker Rudat; Mohamed Hammoud; Yogin Pillay; Abdul Aziz Alaradi; Adel Mohamed; Saleh Altuwaijri
Journal:  Radiat Oncol       Date:  2011-08-24       Impact factor: 3.481

4.  Robotic-based carbon ion therapy and patient positioning in 6 degrees of freedom: setup accuracy of two standard immobilization devices used in carbon ion therapy and IMRT.

Authors:  Alexandra D Jensen; Marcus Winter; Sabine P Kuhn; Jürgen Debus; Olaf Nairz; Marc W Münter
Journal:  Radiat Oncol       Date:  2012-03-29       Impact factor: 3.481

5.  Estimation of adequate setup margins and threshold for position errors requiring immediate attention in head and neck cancer radiotherapy based on 2D image guidance.

Authors:  Mika Kapanen; Marko Laaksomaa; Tapio Tulijoki; Seppo Peltola; Tuija Wigren; Simo Hyödynmaa; Pirkko-Liisa Kellokumpu-Lehtinen
Journal:  Radiat Oncol       Date:  2013-09-10       Impact factor: 3.481

6.  Impact of body-mass factors on setup displacement in patients with head and neck cancer treated with radiotherapy using daily on-line image guidance.

Authors:  Yo-Liang Lai; Shih-Neng Yang; Ji-An Liang; Yao-Ching Wang; Chun-Yen Yu; Ching-Hsiung Su; Shang-Wen Chen
Journal:  Radiat Oncol       Date:  2014-01-10       Impact factor: 3.481

7.  Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient's pain and anxiety.

Authors:  Massimiliano Contesini; Monica Guberti; Roberta Saccani; Luca Braglia; Cinzia Iotti; Andrea Botti; Emilio Abbati; Marina Iemmi
Journal:  Radiat Oncol       Date:  2017-04-27       Impact factor: 3.481

8.  The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique.

Authors:  Qian Yang; Gary Shun-Pan Cheung; Ya Shen; Dingming Huang; Xuedong Zhou; Yuan Gao
Journal:  BMC Oral Health       Date:  2015-07-28       Impact factor: 2.757

9.  Analysis of setup error based on CTVision for nasopharyngeal carcinoma during IGRT.

Authors:  Shuxu Zhang; Xiang Zhou; Quanbin Zhang; Shaohui Jiang; Ruihao Wang; Guoqian Zhang; Huaiyu Lei; Shengqu Lin
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.