Literature DB >> 19025934

MR imaging findings of early bile duct cancer.

Dong Ho Lee1, Jeong Min Lee, Kyung Won Kim, Hee Sun Park, Se Hyung Kim, Jae Young Lee, Joon Koo Han, Byung Ihn Choi.   

Abstract

PURPOSE: To retrospectively evaluate the MR imaging features of early bile duct cancer and to correlate them with the clinicopathologic findings.
MATERIALS AND METHODS: This retrospective study was approved by our institutional review board, and informed consent was waived. Seventeen patients with surgically proven early bile duct cancer who had undergone preoperative MR cholangiopancreatography with gadolinium-enhanced MR imaging, were included in this study. Two, experienced radiologists evaluated the MR images in consensus regarding the following findings: tumor number and morphology; signal intensity of the tumor; sharpness of the outer border of the bile duct wall; enhancement pattern of the tumor; and the presence of enlarged peribiliary lymph nodes. Another radiologist measured the SNR of the tumor and bile duct wall on gadolinium-enhanced MRI during the dynamic phases to evaluate the tumor enhancement degree.
RESULTS: In all patients, MR imaging demonstrated single or multiple intraluminal bile duct masses showing a sharply defined outer margin. The most common enhancement pattern of the biliary lesions showed heterogeneous amorphous enhancement or heterogeneous enhancement with central, dot-like structures or vascular structures (76.5%, 13/17 patients). The difference of SNR between bile duct and tumor was greatest in the equilibrium phase (P < 0.05).
CONCLUSION: MRCP combined with dynamic contrast-enhanced MRI can be useful for detecting early bile duct cancers. Common MR findings of early bile duct cancer include one or more inhomogeneously enhancing intraductal masses with clear outer margins and preservation of the bile duct wall. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19025934     DOI: 10.1002/jmri.21597

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  In Vitro Intraductal MRI and T2 Mapping of Cholangiocarcinoma Using Catheter Coils.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Richard R A Syms
Journal:  Hepat Med       Date:  2020-07-27

Review 2.  Magnetic resonance evaluations of biliary malignancy and condition at high-risk for biliary malignancy: Current status.

Authors:  Reiji Sugita
Journal:  World J Hepatol       Date:  2013-12-27

3.  Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Ian R Young; Richard R A Syms
Journal:  Hepat Med       Date:  2020-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.