Literature DB >> 19021980

Hemodynamic evaluation and midterm outcome of aortic valve replacement with size 19 Perimount prosthetic valve.

Pradeep Narayan1, Barnaby C Reeves, Syad I A Rizvi, Kayvan Shokrollahi, Huda Ismail, Gianni D Angelini, Angus Nightingale, Massimo Caputo.   

Abstract

BACKGROUND: We sought to investigate the effect of patient prosthesis mismatch on hemodynamic profile using dobutamine stress echocardiography, and to evaluate midterm survival of patients undergoing aortic valve replacement with 19-mm Perimount (Baxter Healthcare, Santa Ana, California) aortic prosthetic valves.
METHODS: Between December 1, 1999, and August 17, 2005, 147 patients (mean age, 76.8 +/- 5.51 years) had aortic valves replaced with 19-mm Perimount prostheses. Dobutamine stress echocardiography was performed in a subgroup of 24 patients (mean age, 76.6 +/- 5.60 years). Univariable predictors of peak transprosthetic gradient (PTG) under maximum stress, adjusted for resting PTG, were investigated by regression. Survival in the whole cohort was described, and univariable predictors of survival were investigated by Cox regression.
RESULTS: In the stress echocardiography subgroup, cardiac output (p < 0.0001), PTG (p < 0.0001), and effective orifice area index increased significantly (p = 0.002) under stress. Peak transprosthetic gradient under stress was strongly associated with PTG at rest (p < 0.0001). After controlling for PTG at rest, no other variables were associated with PTG under stress. In the whole cohort, mean duration of follow-up was 2.21 years; 23 patients died. Neither body surface area nor effective orifice area index was significantly associated with survival.
CONCLUSIONS: The 19-mm Perimount aortic prosthesis has acceptable hemodynamic performance. Transvalvular gradients were within a clinically acceptable range, both at rest and under stress. These findings suggest that patient-prosthesis mismatch is unlikely to cause a clinically important problem when the prosthesis is used, which is consistent with survival experience in the whole cohort.

Entities:  

Mesh:

Year:  2008        PMID: 19021980     DOI: 10.1016/j.athoracsur.2008.08.019

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  2 in total

1.  Twelve-year experience with the Carpentier-Edwards pericardial aortic valve at a single Japanese center.

Authors:  Koichi Arinaga; Shuji Fukunaga; Hiroshi Tomoeda; Hidetsugu Hori; Tomohiro Ueda; Ryusuke Mori; Shigeaki Aoyagi
Journal:  J Artif Organs       Date:  2011-05-03       Impact factor: 1.731

Review 2.  Prosthesis-patient mismatch in aortic stenosis.

Authors:  Kentaro Honda; Yoshitaka Okamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.