Literature DB >> 19021344

Multispectral confocal microendoscope for in vivo and in situ imaging.

Houssine Makhlouf1, Arthur F Gmitro, Anthony A Tanbakuchi, Josh A Udovich, Andrew R Rouse.   

Abstract

We describe the design and operation of a multispectral confocal microendoscope. This fiber-based fluorescence imaging system consists of a slit-scan confocal microscope coupled to an imaging catheter that is designed to be minimally invasive and allow for cellular level imaging in vivo. The system can operate in two imaging modes. The grayscale mode of operation provides high resolution real-time in vivo images showing the intensity of fluorescent signal from the specimen. The multispectral mode of operation uses a prism as a dispersive element to collect a full multispectral image of the fluorescence emission. The instrument can switch back and forth nearly instantaneously between the two imaging modes (less than half a second). In the current configuration, the multispectral confocal microendoscope achieves 3-microm lateral resolution and 30-microm axial resolution. The system records light from 500 to 750 nm, and the minimum resolvable wavelength difference varies from 2.9 to 8.3 nm over this spectral range. Grayscale and multispectral imaging results from ex-vivo human tissues and small animal tissues are presented.

Entities:  

Mesh:

Year:  2008        PMID: 19021344      PMCID: PMC4822696          DOI: 10.1117/1.2950313

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  16 in total

1.  Fiber-optic confocal reflectance microscope with miniature objective for in vivo imaging of human tissues.

Authors:  Kung-Bin Sung; Chen Liang; Michael Descour; Tom Collier; Michele Follen; Rebecca Richards-Kortum
Journal:  IEEE Trans Biomed Eng       Date:  2002-10       Impact factor: 4.538

2.  Clinical outcome of a novel photodynamic therapy technique using acridine orange for synovial sarcomas.

Authors:  Katsuyuki Kusuzaki; Hiroaki Murata; Takao Matsubara; Shinichi Miyazaki; Ken Shintani; Masashi Seto; Akihiko Matsumine; Hajime Hosoi; Touru Sugimoto; Atsumasa Uchida
Journal:  Photochem Photobiol       Date:  2005 May-Jun       Impact factor: 3.421

3.  In vivo fiber-optic confocal reflectance microscope with an injection-molded plastic miniature objective lens.

Authors:  Kristen Carlson; Matthew Chidley; Kung-Bin Sung; Michael Descour; Ann Gillenwater; Michele Follen; Rebecca Richards-Kortum
Journal:  Appl Opt       Date:  2005-04-01       Impact factor: 1.980

Review 4.  Confocal laser endoscopy: new approach to the early diagnosis of tumors of the esophagus and stomach.

Authors:  Martin Goetz; Arthur Hoffman; Peter R Galle; Markus F Neurath; Ralf Kiesslich
Journal:  Future Oncol       Date:  2006-08       Impact factor: 3.404

5.  Multispectral imaging with a confocal microendoscope.

Authors:  A R Rouse; A F Gmitro
Journal:  Opt Lett       Date:  2000-12-01       Impact factor: 3.776

6.  Slit-scanning confocal microendoscope for high-resolution in vivo imaging.

Authors:  Y S Sabharwal; A R Rouse; L Donaldson; M F Hopkins; A F Gmitro
Journal:  Appl Opt       Date:  1999-12-01       Impact factor: 1.980

7.  Fibered confocal spectroscopy and multicolor imaging system for in vivo fluorescence analysis.

Authors:  Florence Jean; Genevieve Bourg-Heckly; Bertrand Viellerobe
Journal:  Opt Express       Date:  2007-04-02       Impact factor: 3.894

8.  Fluorescence microscopy of lysosomes and related structures in living cells.

Authors:  A V Zelenin
Journal:  Nature       Date:  1966-10-22       Impact factor: 49.962

9.  Interactions of acridine orange with nucleic acids. Properties of complexes of acridine orange with single stranded ribonucleic acid.

Authors:  J Kapuscinski; Z Darzynkiewicz; M R Melamed
Journal:  Biochem Pharmacol       Date:  1983-12-15       Impact factor: 5.858

10.  Confocal laser endoscopy for diagnosing intraepithelial neoplasias and colorectal cancer in vivo.

Authors:  Ralf Kiesslich; Juergen Burg; Michael Vieth; Janina Gnaendiger; Meike Enders; Peter Delaney; Adrian Polglase; Wendy McLaren; Daniela Janell; Steven Thomas; Bernhard Nafe; Peter R Galle; Markus F Neurath
Journal:  Gastroenterology       Date:  2004-09       Impact factor: 22.682

View more
  20 in total

1.  Fiber-optic nonlinear endomicroscopy with focus scanning by using shape memory alloy actuation.

Authors:  Yicong Wu; Yuying Zhang; Jiefeng Xi; Ming-Jun Li; Xingde Li
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

2.  In vivo reflectance confocal microscopy of shave biopsy wounds: feasibility of intraoperative mapping of cancer margins.

Authors:  A Scope; U Mahmood; D S Gareau; M Kenkre; J A Lieb; K S Nehal; M Rajadhyaksha
Journal:  Br J Dermatol       Date:  2010-12       Impact factor: 9.302

3.  Optimizing the performance of dual-axis confocal microscopes via Monte-Carlo scattering simulations and diffraction theory.

Authors:  Ye Chen; Jonathan T C Liu
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

4.  High speed, line-scanning, fiber bundle fluorescence confocal endomicroscopy for improved mosaicking.

Authors:  Michael Hughes; Guang-Zhong Yang
Journal:  Biomed Opt Express       Date:  2015-03-12       Impact factor: 3.732

5.  Tri-modal confocal mosaics detect residual invasive squamous cell carcinoma in Mohs surgical excisions.

Authors:  Dan Gareau; Anna Bar; Nicholas Snaveley; Ken Lee; Nathaniel Chen; Neil Swanson; Eric Simpson; Steve Jacques
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

6.  Fiber bundle endocytoscopy.

Authors:  Michael Hughes; Tou Pin Chang; Guang-Zhong Yang
Journal:  Biomed Opt Express       Date:  2013-11-11       Impact factor: 3.732

7.  Line-scanning fiber bundle endomicroscopy with a virtual detector slit.

Authors:  Michael Hughes; Guang-Zhong Yang
Journal:  Biomed Opt Express       Date:  2016-05-18       Impact factor: 3.732

8.  Comparison of line-scanned and point-scanned dual-axis confocal microscope performance.

Authors:  D Wang; Y Chen; Y Wang; J T C Liu
Journal:  Opt Lett       Date:  2013-12-15       Impact factor: 3.776

9.  Miniature in vivo MEMS-based line-scanned dual-axis confocal microscope for point-of-care pathology.

Authors:  C Yin; A K Glaser; S Y Leigh; Y Chen; L Wei; P C S Pillai; M C Rosenberg; S Abeytunge; G Peterson; C Glazowski; N Sanai; M J Mandella; M Rajadhyaksha; J T C Liu
Journal:  Biomed Opt Express       Date:  2016-01-05       Impact factor: 3.732

10.  Pilot Clinical Evaluation of a Confocal Microlaparoscope for Ovarian Cancer Detection.

Authors:  Matthew D Risi; Andrew R Rouse; Setsuko K Chambers; Kenneth D Hatch; Wenxin Zheng; Arthur F Gmitro
Journal:  Int J Gynecol Cancer       Date:  2016-02       Impact factor: 3.437

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.