Literature DB >> 19020694

The minimal detectable change of the simplified stroke rehabilitation assessment of movement measure.

Wen-Shian Lu1, Chun-Hou Wang, Jao-Hong Lin, Ching-Fan Sheu, Ching-Lin Hsieh.   

Abstract

OBJECTIVE: To help clinicians and researchers interpret change scores of the simplified Stroke Rehabilitation Assessment of Movement measure, we estimated the minimal detectable change of the 3 subscales (including upper-limb movements, lower-limb movements, and mobility) of the measure. DESIGN AND PATIENTS: The measure was tested on 102 patients with chronic stroke by a single rater twice, with a 7-14-day interval for the test-retest study, and on 54 patients with sub-acute stroke by 2 raters twice, with a 2-day interval for the inter-rater study.
METHODS: The minimal detectable change was calculated on the basis of standard error of measurement. Furthermore, the intraclass correlation coefficient was used to examine the agreement between test and retest and between different raters.
RESULTS: The minimal detectable changes were from 12.5 to 13.2 points for the 3 subscales in the test-retest study and from 16.6 to 18.5 points in the inter-rater study. The test-retest agreement and the inter-rater agreement were sufficient (intraclass correlation coefficient = 0.88-0.96).
CONCLUSION: The minimal detectable changes of the simplified Stroke Rehabilitation Assessment of Movement measure are useful for both clinicians and researchers to determine whether the change score of an individual patient is real.

Entities:  

Mesh:

Year:  2008        PMID: 19020694     DOI: 10.2340/16501977-0230

Source DB:  PubMed          Journal:  J Rehabil Med        ISSN: 1650-1977            Impact factor:   2.912


  18 in total

1.  Minimal detectable change of the actual amount of use test and the motor activity log: the EXCITE Trial.

Authors:  Shuya Chen; Steven L Wolf; Qin Zhang; Paul A Thompson; Carolee J Winstein
Journal:  Neurorehabil Neural Repair       Date:  2012-01-24       Impact factor: 3.919

2.  A wearable resistive robot facilitates locomotor adaptations during gait.

Authors:  Edward P Washabaugh; Chandramouli Krishnan
Journal:  Restor Neurol Neurosci       Date:  2018       Impact factor: 2.406

3.  Test-Retest Reliability of the Postural Vertical in Healthy Participants.

Authors:  Yuji Fujino; Kazu Amimoto; Kazuhiro Fukata; Masahide Inoue; Kohei Shida; Hidetoshi Takahashi; Shigeru Makita
Journal:  Prog Rehabil Med       Date:  2017-12-06

4.  Translation and Validation of Forgotten Joint Score for Total Hip Arthroplasty for Indian Population.

Authors:  Siddharth S Sethy; Tarun Goyal; Souvik Paul; S Lakshmana Das; Arghya Kundu Choudhury; Roop Bhushan Kalia
Journal:  Indian J Orthop       Date:  2020-08-17       Impact factor: 1.251

5.  Test-retest reliability and validity of the Sitting Balance Measure-Korean in individuals with incomplete spinal cord injury.

Authors:  JunMin Lee; SeungHeon An; OnYoo Kim; GyuMin Kang; Myungki Kim
Journal:  Spinal Cord       Date:  2021-11-15       Impact factor: 2.473

6.  Back pain attitudes questionnaire: Cross-cultural adaptation to brazilian-portuguese and measurement properties.

Authors:  Roberto Costa Krug; J P Caneiro; Daniel Cury Ribeiro; Ben Darlow; Marcelo Faria Silva; Jefferson Fagundes Loss
Journal:  Braz J Phys Ther       Date:  2020-07-14       Impact factor: 3.377

7.  Validity and repeatability of inertial measurement units for measuring gait parameters.

Authors:  Edward P Washabaugh; Tarun Kalyanaraman; Peter G Adamczyk; Edward S Claflin; Chandramouli Krishnan
Journal:  Gait Posture       Date:  2017-04-12       Impact factor: 2.840

8.  Predicting recovery of voluntary upper extremity movement in subacute stroke patients with severe upper extremity paresis.

Authors:  Chia-Lin Koh; Shin-Liang Pan; Jiann-Shing Jeng; Bang-Bin Chen; Yen-Ho Wang; I-Ping Hsueh; Ching-Lin Hsieh
Journal:  PLoS One       Date:  2015-05-14       Impact factor: 3.240

9.  Determination and comparison of the smallest detectable change (SDC) and the minimal important change (MIC) of four-shoulder patient-reported outcome measures (PROMs).

Authors:  Derk A van Kampen; W Jaap Willems; Loes W A H van Beers; Rene M Castelein; Vanessa A B Scholtes; Caroline B Terwee
Journal:  J Orthop Surg Res       Date:  2013-11-14       Impact factor: 2.359

10.  Simplified Radiographic Damage Index for Affected Joints in Chronic Gouty Arthritis.

Authors:  Chang-Nam Son; Tae Eun Kim; Kyungmin Park; Jun Hyun Hwang; Seong-Kyu Kim
Journal:  J Korean Med Sci       Date:  2016-02-17       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.