Literature DB >> 19015221

Extracting respiratory data from pulse oximeter plethysmogram traces in newborn infants.

D Wertheim1, C Olden, E Savage, P Seddon.   

Abstract

To investigate whether valid respiratory data can be extracted from the pulse oximeter plethysmographic (pleth) trace in healthy newborn infants, pleth data were collected from the foot, and respiratory airflow was simultaneously measured using a facemask. The pleth waveform was analysed using fast Fourier transform (FFT), low-pass filtering (LPF), and by plotting the peak-to-peak amplitude variation (PtP). Using FFT in 14 term infants, the median (range) respiratory rate from the pleth signal was 43 (30-65) breaths/min, and from the flow signal it was 44 (30-67) breaths/min (median difference 0.01 breaths/min, p>0.05). Both LPF and PtP analysis yielded waveforms with a frequency similar to the respiratory rate. Respiratory information, including respiratory rate and a respiratory-like waveform, can reliably be extracted from the pleth trace of a standard pulse oximeter in newborn infants. Such analysis may be clinically useful for non-invasive assessment of respiratory problems in infants and young children.

Entities:  

Mesh:

Year:  2008        PMID: 19015221     DOI: 10.1136/adc.2008.145342

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  4 in total

1.  Developing an algorithm for pulse oximetry derived respiratory rate (RR(oxi)): a healthy volunteer study.

Authors:  Paul S Addison; James N Watson; Michael L Mestek; Roger S Mecca
Journal:  J Clin Monit Comput       Date:  2012-01-10       Impact factor: 2.502

2.  Monitoring respiration in wheezy preschool children by pulse oximetry plethysmogram analysis.

Authors:  David Wertheim; Cathy Olden; Liz Symes; Heike Rabe; Paul Seddon
Journal:  Med Biol Eng Comput       Date:  2013-04-01       Impact factor: 2.602

3.  Pulse oximetry-derived respiratory rate in general care floor patients.

Authors:  Paul S Addison; James N Watson; Michael L Mestek; James P Ochs; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-05-06       Impact factor: 2.502

Review 4.  Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

Authors:  Peter H Charlton; Drew A Birrenkott; Timothy Bonnici; Marco A F Pimentel; Alistair E W Johnson; Jordi Alastruey; Lionel Tarassenko; Peter J Watkinson; Richard Beale; David A Clifton
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.