Literature DB >> 19013071

The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements.

Shameem A C Sampath1, South H Voon, Marshall Sangster, Howard Davies.   

Abstract

The outcome of total knee arthroplasty (TKA) with severe pre-operative varus deformity is significantly worse than in well aligned knees. Computer navigated TKA has addressed some of the problems by ensuring accurate post-operative alignment. Our aims were to see if navigation could reproducibly correct a varus deformity to 3 degrees of the mechanical axis and to investigate the relationships between the tourniquet time and severity of the preoperative deformity, BMI and a surgeon's experience. The 172 e.motion floating platform TKA's were implanted using the OrthoPilot Navigation system (B Braun-Aesculap, Tuttlingen, Germany). Pre-operative deformity and post-operative alignment were measured by the software. Tourniquet times were recorded automatically. All knees were corrected to within 3 degrees of the neutral axis (mean 0.48 degrees ). Statistically significant relationships between tourniquet time (TT) and degree of pre-operative varus (p<0.001), total number of previous e.motion TKA's performed (p<0.001), and body mass index (p=0.013) were found. A linear relationship between the variables can be expressed as a statistical formula: TT=49.5+PreOp Varus+0.6(BMI)-0.1(total previous). Tourniquet time is measured in minutes and preoperative varus is measured in degrees from the mechanical axis. Total previous is the total number of navigated TKA's implanted by the surgeon. Tourniquet time is increased with larger pre-operative deformities and high BMI and decreased with surgical experience. The formula may give us a method of predicting the length of a procedure for a particular surgical team and may allow us to plan operating lists more accurately.

Entities:  

Mesh:

Year:  2008        PMID: 19013071     DOI: 10.1016/j.knee.2008.09.008

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  13 in total

1.  Relationship between cutting errors and learning curve in computer-assisted total knee replacement.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-06-10       Impact factor: 3.075

Review 2.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

3.  Adjustable cutting blocks improve alignment and surgical time in computer-assisted total knee replacement.

Authors:  Eduardo M Suero; Christopher Plaskos; Peter L Dixon; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-25       Impact factor: 4.342

4.  Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

Authors:  Michael E Steinhaus; Alexander S McLawhorn; Shawn S Richardson; Patrick Maher; David J Mayman
Journal:  HSS J       Date:  2016-02-29

5.  Frontal plane alignment after total knee arthroplasty using patient-specific instruments.

Authors:  Kiriakos Daniilidis; Carsten O Tibesku
Journal:  Int Orthop       Date:  2012-12-12       Impact factor: 3.075

6.  A comparison of conventional and patient-specific instruments in total knee arthroplasty.

Authors:  Kiriakos Daniilidis; Carsten O Tibesku
Journal:  Int Orthop       Date:  2013-07-31       Impact factor: 3.075

7.  Total knee arthroplasty: Effect of obesity and other patients' characteristics on operative duration and outcome.

Authors:  Abdulaziz Saud Al Turki; Yazeed Al Dakhil; Abdulah Al Turki; Mazen Saleh Ferwana
Journal:  World J Orthop       Date:  2015-03-18

8.  Residual varus alignment does not compromise results of TKAs in patients with preoperative varus.

Authors:  Robert A Magnussen; Florent Weppe; Guillaume Demey; Elvire Servien; Sébastien Lustig
Journal:  Clin Orthop Relat Res       Date:  2011-07-26       Impact factor: 4.176

9.  Is computer-assisted total knee replacement for beginners or experts? Prospective study among three groups of patients treated by surgeons with different levels of experience.

Authors:  Norberto Confalonieri; Cesare Chemello; Pietro Cerveri; Alfonso Manzotti
Journal:  J Orthop Traumatol       Date:  2012-07-18

10.  Robot-Assisted Navigation versus Computer-Assisted Navigation in Primary Total Knee Arthroplasty: Efficiency and Accuracy.

Authors:  Tanner C Clark; Frank H Schmidt
Journal:  ISRN Orthop       Date:  2013-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.