Literature DB >> 18998145

[IOL calculation for high ametropia].

W Haigis1.   

Abstract

Long and short eyes are connected with high ametropia and constitute special problems for biometry and IOL calculations. Ultrasound measurements on these eyes, which often have altered geometries, are frequently more difficult than in normal eyes. This holds especially for long eyes, which significantly benefit from optical biometry. Measurement errors, IOL manufacturing tolerances and uncertainties regarding the effective lens position affect short eyes much more than normal eyes. The selection of a suitable IOL formula is of special importance for the refractive outcome. For short eyes, Holladay-2, HofferQ and Haigis are recommended, for long eyes Holladay-1, Holladay-2 and Haigis. In each case, optimized IOL constants must be used. If minus lenses for extremely long eyes are calculated with the same constants as plus lenses, a hyperopic refractive error is created, which can be avoided by a separate set of constants for minus lenses. For extremely short eyes the commonly used approximation of thinner lenses fails necessitating a thick lens calculation or raytracing.

Entities:  

Mesh:

Year:  2008        PMID: 18998145     DOI: 10.1007/s00347-008-1828-6

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  11 in total

Review 1.  [Consistent numerical calculation of optics of the pseudophakic eye].

Authors:  P R Preussner; J Wahl
Journal:  Ophthalmologe       Date:  2000-02       Impact factor: 1.059

2.  Biometry accuracy using zero- and negative-powered intraocular lenses.

Authors:  Robert E MacLaren; Mandeep S Sagoo; Marie Restori; Bruce D S Allan
Journal:  J Cataract Refract Surg       Date:  2005-02       Impact factor: 3.351

3.  Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length.

Authors:  Jia-Kang Wang; Chao-Yu Hu; Shu-Wen Chang
Journal:  J Cataract Refract Surg       Date:  2008-02       Impact factor: 3.351

4.  Axial length measurements and fundus changes of the myopic eye.

Authors:  B J Curtin; D B Karlin
Journal:  Am J Ophthalmol       Date:  1971-01       Impact factor: 5.258

Review 5.  Refractive lens exchange combined with pars plana vitrectomy to correct high myopia.

Authors:  S Uhlmann; P Wiedemann
Journal:  Eye (Lond)       Date:  2005-06-10       Impact factor: 3.775

6.  The Hoffer Q formula: a comparison of theoretic and regression formulas.

Authors:  K J Hoffer
Journal:  J Cataract Refract Surg       Date:  1993-11       Impact factor: 3.351

7.  Intraocular lens calculation: the problem of the short eye.

Authors:  K J Hoffer
Journal:  Ophthalmic Surg       Date:  1981-04

8.  Reliability of intraocular lens power calculation after cataract surgery in patients with relative anterior microphthalmos.

Authors:  T U Bartke; G U Auffarth; J C Uhl; H E Völcker
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-02       Impact factor: 3.117

9.  Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia.

Authors:  Robert E MacLaren; Mythili Natkunarajah; Yasmin Riaz; Rupert R A Bourne; Marie Restori; Bruce D S Allan
Journal:  Am J Ophthalmol       Date:  2007-06       Impact factor: 5.258

10.  Contact lens wear and IOL power calculation before cataract surgery: a cautionary tale.

Authors:  D Q Nguyen; K N Hakin
Journal:  J Refract Surg       Date:  2006-02       Impact factor: 3.573

View more
  4 in total

1.  [Light adjustable lens. New options for customized correction of presbyopia].

Authors:  F H Hengerer; J Böcker; B H Dick; I Conrad-Hengerer
Journal:  Ophthalmologe       Date:  2012-07       Impact factor: 1.059

Review 2.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

Review 3.  Cataract surgery with implantation of an artificial lens.

Authors:  Thomas Kohnen; Martin Baumeister; Daniel Kook; Oliver K Klaproth; Christian Ohrloff
Journal:  Dtsch Arztebl Int       Date:  2009-10-23       Impact factor: 5.594

4.  [Cataract surgery in glaucoma patients. Perioperative aspects].

Authors:  T S Dietlein; T Kohnen; A Rosentreter; A Lappas
Journal:  Ophthalmologe       Date:  2013-04       Impact factor: 1.059

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.