Literature DB >> 18996982

Effects of increasing age onto procedural parameters in pacemaker implantation: results of an obligatory external quality control program.

Bernd Nowak1, Björn Misselwitz.   

Abstract

AIMS: The aim of the study was to evaluate the effects of increasing patients' age onto procedural parameters, especially complications, during primary pacemaker implantation, evaluating the database of the Institute of Quality Assurance Hessen in the federal state of Hessen, Germany. METHODS AND
RESULTS: The database of the obligatory external quality control program was evaluated retrospectively for the years 2003-2006. A total of 17 826 patients undergoing stationary primary pacemaker implantation have been registered in 72 centres. In single-chamber implants, the implant duration is shortest in non-agenarians. For dual-chamber implants, the implant duration shortens with increasing age. Thus, as well as fluoroscopy time is significantly shorter in the oldest patients. Atrial and ventricular pacing thresholds as well as R-wave amplitudes do not change with age. P-wave amplitudes showed a small but steady decline with increasing ages. Complications do not increase with advanced age.
CONCLUSION: In this large-scale real-life patient cohort of primary stationary pacemaker implantation, increasing age resulted only in reduced P-wave amplitudes. Higher age was not associated with an increased risk of complications. Thus, pacemaker implantations in the elderly can be performed with the same reliability as in younger patients.

Entities:  

Mesh:

Year:  2008        PMID: 18996982     DOI: 10.1093/europace/eun293

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  5 in total

1.  [Scientific results of the pacemaker register: possibilities and limits].

Authors:  U K H Wiegand; B Lemke; B Nowak
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-09

Review 2.  [Problems, complications, and emergencies during pacemaker implantation. Importance of access].

Authors:  Carsten W Israel; Lucy Ekosso-Ejangue
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-12

3.  Pacemaker implantation in the extreme elderly.

Authors:  Robert T Stevenson; David Lugg; Robert Gray; Douglas Hollis; Michelle Stoner; Jeffrey L Williams
Journal:  J Interv Card Electrophysiol       Date:  2011-09-23       Impact factor: 1.900

4.  Evaluation of patients' quality of life aspects after cardiac pacemaker implantation.

Authors:  Rubens Tofano de Barros; Sebastião Marcos Ribeiro de Carvalho; Marcos Augusto de Moraes Silva; Juliana Bassalobre Carvalho Borges
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jan-Mar

5.  Complications of Cardiac Perforation and Lead Dislodgement with an MRI-Conditional Pacing Lead: a Korean Multi-Center Experience.

Authors:  Chang Hee Kwon; Jin Hee Choi; Jun Kim; Uk Jo; Ji Hyun Lee; Woo Seok Lee; Yoo Ri Kim; Soo Yong Lee; Ki Won Whang; Jihyun Yang; Sung Hwan Kim; Yong Seog Oh; Kyoung Min Park; Gi Byoung Nam; Kee Joon Choi; You Ho Kim
Journal:  J Korean Med Sci       Date:  2016-09       Impact factor: 2.153

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.