Literature DB >> 18988279

Evaluation of sequentially crosslinked ultra-high molecular weight polyethylene.

M L Morrison1, S Jani.   

Abstract

This study was undertaken to investigate the effect of crosslinking ultra-high molecular weight polyethylene (UHMWPE) in a sequential manner to the final desired dose and to compare the results to single-dose crosslinking. To verify these results, an explanted, commercially available, sequentially crosslinked component was characterized. Finally, additional tensile testing was conducted to determine if tensile-sample thickness has a significant effect on the mechanical properties of UHMWPE. Based upon this well-controlled study with the same starting material, there is no apparent benefit of sequential crosslinking over crosslinking by single dose in any of the mechanical, thermophysical, physical, or oxidative properties evaluated in this study. In contrast, the soak temperature of the postirradiation heat treatment was more influential and exhibited statistically significant effects on the stability, structure, and properties of the resultant material. Compared to virgin material, crosslinking always resulted in decreases in tensile strength, elongation, and impact strength. These results were confirmed by characterization of a retrieved, sequentially crosslinked (X3) cup. All of the metrics derived for the retrieved cup were virtually identical to the sequential- and single-dose-crosslinked materials produced in this study. Examination of the effect of tensile-sample thickness demonstrated that there are significant effects on the resultant properties. In particular, the ultimate tensile strength of UHMWPE can be elevated by conducting tensile tests with thin specimens. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18988279     DOI: 10.1002/jbm.b.31257

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

Review 1.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

Review 3.  Highly cross-linked polyethylene may not have an advantage in total knee arthroplasty.

Authors:  Vasileios I Sakellariou; Peter Sculco; Lazaros Poultsides; Timothy Wright; Thomas P Sculco
Journal:  HSS J       Date:  2013-08-10

4.  Microstructural modifications induced by accelerated aging and lipid absorption in remelted and annealed UHMWPEs for total hip arthroplasty.

Authors:  Leonardo Puppulin; Wenliang Zhu; Nobuhiko Sugano; Giuseppe Pezzotti
Journal:  J Biomater Appl       Date:  2014-08-31       Impact factor: 2.646

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.