Literature DB >> 18987963

Lead extraction: a new effective tool to overcome fibrous binding sites.

Antonio Dello Russo1, Roberto Biddau, Gemma Pelargonio, Michela Casella, Antonio Frontera, Antonella Camporeale, Caterina Bisceglia, Giovanni B Forleo, Claudio Tondo, Paolo Zecchi, Fulvio Bellocci.   

Abstract

We report the case of a 50 year-old woman referred for extraction of an infected biventricular implantable cardioverter defibrillator (ICD) who underwent device and leads extraction. Due to adhesions at the level of the subclavian-innominate vein angle, manual traction with locking stylet was ineffective. A new mechanical sheath provided with a stainless steel bladed tip, the Evolution Mechanical Dilator Sheath (Cook Medical), was successfully used to complete lead extraction. As far as we know, this is the first report on the use of this new tool; its safety should be ascertained by increasing the number of cases but its simple use and its low cost make the Evolution Mechanical Dilator Sheath a new interesting tool that can be added to the instruments available for lead extraction.

Entities:  

Mesh:

Year:  2008        PMID: 18987963     DOI: 10.1007/s10840-008-9326-y

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  8 in total

Review 1.  Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty.

Authors:  C J Love; B L Wilkoff; C L Byrd; P H Belott; J A Brinker; N E Fearnot; R A Friedman; S Furman; L B Goode; D L Hayes; D T Kawanishi; V Parsonnet; C Reiser; H J Van Zandt
Journal:  Pacing Clin Electrophysiol       Date:  2000-04       Impact factor: 1.976

2.  Clinical study of the laser sheath for lead extraction: the total experience in the United States.

Authors:  Charles L Byrd; Bruce L Wilkoff; Charles J Love; T Duncan Sellers; Christopher Reiser
Journal:  Pacing Clin Electrophysiol       Date:  2002-05       Impact factor: 1.976

Review 3.  Pacemaker and defibrillator lead extraction.

Authors:  Steven P Kutalek
Journal:  Curr Opin Cardiol       Date:  2004-01       Impact factor: 2.161

4.  ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (writing committee to develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society.

Authors:  Douglas P Zipes; A John Camm; Martin Borggrefe; Alfred E Buxton; Bernard Chaitman; Martin Fromer; Gabriel Gregoratos; George Klein; Arthur J Moss; Robert J Myerburg; Silvia G Priori; Miguel A Quinones; Dan M Roden; Michael J Silka; Cynthia Tracy; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Elliott M Antman; Jeffrey L Anderson; Sharon A Hunt; Jonathan L Halperin; Rick Nishimura; Joseph P Ornato; Richard L Page; Barbara Riegel; Jean-Jacques Blanc; Andrzej Budaj; Veronica Dean; Jaap W Deckers; Catherine Despres; Kenneth Dickstein; John Lekakis; Keith McGregor; Marco Metra; Joao Morais; Ady Osterspey; Juan Luis Tamargo; José Luis Zamorano
Journal:  Circulation       Date:  2006-08-25       Impact factor: 29.690

5.  Residual fibrous tissue floating in the right atrium after percutaneous pacemaker lead extraction: an unusual complication early detected by intracardiac echocardiography.

Authors:  Vittoria Rizzello; Antonio Dello Russo; Michela Casella; Roberto Biddau
Journal:  Int J Cardiol       Date:  2007-06-22       Impact factor: 4.164

6.  Guidelines for cardiac pacing and cardiac resynchronization therapy. The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association.

Authors:  Panos E Vardas; Angelo Auricchio; Jean-Jacques Blanc; Jean-Claude Daubert; Helmut Drexler; Hugo Ector; Maurizio Gasparini; Cecilia Linde; Francisco Bello Morgado; Ali Oto; Richard Sutton; Maria Trusz-Gluza
Journal:  Europace       Date:  2007-08-28       Impact factor: 5.214

7.  Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial.

Authors:  Petr Neuzil; Milos Taborsky; Zdenek Rezek; Roman Vopalka; Lucie Sediva; Petr Niederle; Vivek Reddy
Journal:  Europace       Date:  2007-02       Impact factor: 5.214

8.  Laser-assisted lead extraction: the European experience.

Authors:  C Kennergren; C A Bucknall; C Butter; R Charles; J Fuhrer; M Grosfeld; R Tavernier; T B Morgado; P Mortensen; V Paul; P Richter; T Schwartz; F Wellens
Journal:  Europace       Date:  2007-06-27       Impact factor: 5.214

  8 in total
  2 in total

1.  Comparison between laser sheaths, femoral approach and rotating mechanical sheaths for lead extraction.

Authors:  F A Bracke; N Rademakers; N Verberkmoes; M Van 't Veer; B M van Gelder
Journal:  Neth Heart J       Date:  2021-12-21       Impact factor: 2.854

2.  Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction.

Authors:  Robert G Hauser; William T Katsiyiannis; Charles C Gornick; Adrian K Almquist; Linda M Kallinen
Journal:  Europace       Date:  2009-11-27       Impact factor: 5.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.