Literature DB >> 18986338

Quantitative functional imaging and kinetic studies with high-Z contrast agents using synchrotron radiation computed tomography.

J F Adam1, S Bayat, L Porra, H Elleaume, F Estève, P Suortti.   

Abstract

1. There is an increasing demand in diagnostic radiology for extracting additional morphological and functional quantitative parameters from three-dimensional computed tomography (CT) images. Synchrotron radiation computed tomography (SRCT) is the state-of-the-art method in preclinical X-ray CT, because its performance is close to the theoretical limits in terms of accuracy and precision. 2. The SRCT method with monochromatic X-ray beams yields absolute high-Z element contrast agent concentrations, without errors arising from beam hardening or scatter artefacts, by using digital subtraction techniques of the sinograms. Each pixel of the reconstructed difference images provides a quantitative concentration versus time curve of inhaled or injected high-Z contrast agents (xenon or iodine) with a high sensitivity. This is the key point of two functional imaging techniques that were developed at the European Synchrotron Radiation Facility: brain perfusion and lung function (ventilation and perfusion). 3. These two imaging techniques provide parametric images expressed in absolute perfusion parameters (blood volume, blood flow, mean transit time and capillary permeability) or ventilation parameters (lung volume, regional lung ventilation, bronchial lumen size, regional airway and lung compliance) with a high accuracy and precision. 4. The aim of the present brief review is to give a snapshot of the status and perspectives of these two imaging techniques, with emphasis on the performances and interests for functional imaging. Two separate sections will then describe the results obtained so far using SRCT as an in vivo functional imaging tool for measuring changes in haemodynamics and ventilation, in the investigation of experimental pathophysiology and in the effects of therapeutic intervention.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18986338     DOI: 10.1111/j.1440-1681.2008.05043.x

Source DB:  PubMed          Journal:  Clin Exp Pharmacol Physiol        ISSN: 0305-1870            Impact factor:   2.557


  4 in total

1.  Interactions between synchrotron radiation X-ray and biological tissues - theoretical and clinical significance.

Authors:  Heyu Chen; Xin He; Caibin Sheng; Yingxin Ma; Hui Nie; Weiliang Xia; Weihai Ying
Journal:  Int J Physiol Pathophysiol Pharmacol       Date:  2011-10-11

2.  Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors.

Authors:  Dimple Modgil; David S Rigie; Yuxin Wang; Xianghui Xiao; Phillip A Vargas; Patrick J La Rivière
Journal:  Phys Med Biol       Date:  2015-09-30       Impact factor: 3.609

3.  Automated computer-assisted quantitative analysis of intact murine lungs at the alveolar scale.

Authors:  Goran Lovric; Ioannis Vogiatzis Oikonomidis; Rajmund Mokso; Marco Stampanoni; Matthias Roth-Kleiner; Johannes C Schittny
Journal:  PLoS One       Date:  2017-09-21       Impact factor: 3.240

4.  Respiratory-gated KES imaging of a rat model of acute lung injury at the Canadian Light Source.

Authors:  P Deman; S Tan; G Belev; N Samadi; M Martinson; D Chapman; N L Ford
Journal:  J Synchrotron Radiat       Date:  2017-03-21       Impact factor: 2.616

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.