Literature DB >> 18985795

Tensile and tribological properties of high-crystallinity radiation crosslinked UHMWPE.

Alessandro Bistolfi1, Mary Beth Turell, Ying-Lung Lee, Anuj Bellare.   

Abstract

Osteolysis due to particulate wear debris associated with ultrahigh molecular weight polyethylene (UHMWPE) components of total joint replacement prostheses has been a major factor determining their in vivo lifetime. In recent years, radiation crosslinking has been employed to decrease wear rates in PE components, especially in acetabular cups of total hip replacement prostheses. A drawback of radiation crosslinking is that it leads to a crosslinked PE (or XPE) with lower mechanical properties compared with uncrosslinked PE. In contrast, high-crystallinity PEs are known to have several mechanical properties higher than conventional PE. In this study, we hypothesized that increasing the crystallinity of radiation crosslinked and remelted XPE would result in an increase in tensile properties without compromising wear resistance. High-pressure crystallization was performed on PE and XPE and analyzed for the resulting morphological alterations using differential scanning calorimeter, low voltage scanning electron microscopy, and ultrasmall angle X-ray scattering. Uniaxial tensile tests showed that high-pressure crystallization increased the tensile modulus and yield stress in both PE and XPE, decreased the ultimate strain and ultimate stress in PE but had no significant effect on ultimate strain or ultimate stress in XPE. Multidirectional wear tests demonstrated that high-pressure crystallization decreased the wear resistance of PE but had no effect on the wear resistance of XPE. In conclusion, this study shows that high-pressure crystallization can be effectively used to increase the crystallinity and modulus of XPE without compromising its superior wear resistance compared with PE. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18985795     DOI: 10.1002/jbm.b.31265

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  Do crosslinking and vitamin E stabilization influence microbial adhesions on UHMWPE-based biomaterials?

Authors:  Giuliana Banche; Pierangiola Bracco; Valeria Allizond; Alessandro Bistolfi; Michele Boffano; Andrea Cimino; Elena Maria Brach del Prever; Anna Maria Cuffini
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

2.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

Review 3.  Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: The present and the future.

Authors:  Alessandro Bistolfi; Fortunato Giustra; Francesco Bosco; Luigi Sabatini; Alessandro Aprato; Pierangiola Bracco; Anuj Bellare
Journal:  J Orthop       Date:  2021-04-23

4.  Engineering alloplastic temporomandibular joint replacements.

Authors:  Hani Sinno; Youssef Tahiri; Mirko Gilardino; Dennis Bobyn
Journal:  Mcgill J Med       Date:  2011-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.