Literature DB >> 18985701

Mechanical characterization of external fixator stiffness for a rat femoral fracture model.

Bettina Willie1, Kyle Adkins, Xing Zheng, Ulrich Simon, Lutz Claes.   

Abstract

Clinical and experimental studies have shown that several mechanical factors influence the fracture healing process. One such factor, interfragmentary movement, is affected by loading and the stiffness of the fixation device. This study evaluated the stiffness of different external fixation devices for a rat femoral fracture model, using in vitro and analytical methods. The contribution to the stiffness of the fixation construct was dominated by the flexibility of the pins in relation to their offset, diameter, and material properties. The axial stiffness increased with decreasing offset and increasing pin diameter. Titanium pins resulted in significantly lower axial stiffness compared to stainless steel pins of the same design. The fixator body material and fixator length had a less pronounced influence on fixation stiffness. Mechanically characterized external fixation devices will allow in vivo study of the fracture healing process utilizing pre-calculated fracture fixation stiffness. These characterized fixation devices will allow controlled manipulation of the axial and shear interfragmentary movement to achieve a flexible fixation resulting in callus formation compared to a more rigid fixation limiting callus formation in a rat femoral fracture model. Copyright 2008 Orthopaedic Research Society

Entities:  

Mesh:

Year:  2009        PMID: 18985701     DOI: 10.1002/jor.20792

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  11 in total

1.  Temporal variation in fixation stiffness affects healing by differential cartilage formation in a rat osteotomy model.

Authors:  Bettina M Willie; Robert Blakytny; Melanie Glöckelmann; Anita Ignatius; Lutz Claes
Journal:  Clin Orthop Relat Res       Date:  2011-11       Impact factor: 4.176

Review 2.  Biomaterial delivery of morphogens to mimic the natural healing cascade in bone.

Authors:  Manav Mehta; Katharina Schmidt-Bleek; Georg N Duda; David J Mooney
Journal:  Adv Drug Deliv Rev       Date:  2012-05-22       Impact factor: 15.470

Review 3.  Fracture healing under healthy and inflammatory conditions.

Authors:  Lutz Claes; Stefan Recknagel; Anita Ignatius
Journal:  Nat Rev Rheumatol       Date:  2012-01-31       Impact factor: 20.543

4.  Generation of closed transverse fractures in small animals.

Authors:  Anthony De Giacomo; Elise F Morgan; Louis C Gerstenfeld
Journal:  Methods Mol Biol       Date:  2014

5.  Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.

Authors:  Vaida Glatt; Romano Matthys
Journal:  J Vis Exp       Date:  2014-10-09       Impact factor: 1.355

6.  A Novel In Vivo Joint Loading System to Investigate the Effect of Daily Mechanical Load on a Healing Anterior Cruciate Ligament Reconstruction.

Authors:  Mark Stasiak; Carl Imhauser; Jonathan Packer; Asheesh Bedi; Robert Brophy; David Kovacevic; Kent Jackson; Xiang-Hua Deng; Scott Rodeo; Peter Torzilli
Journal:  J Med Device       Date:  2010       Impact factor: 0.582

7.  Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies.

Authors:  Nicholaus Meyers; Matthias Sukopp; Rudolf Jäger; Malte Steiner; Romano Matthys; Bernd Lapatki; Anita Ignatius; Lutz Claes
Journal:  PLoS One       Date:  2017-04-28       Impact factor: 3.240

8.  Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing.

Authors:  Nicole Bartnikowski; Lutz E Claes; Lidia Koval; Vaida Glatt; Ronny Bindl; Roland Steck; Anita Ignatius; Michael A Schuetz; Devakara R Epari
Journal:  Acta Orthop       Date:  2016-11-14       Impact factor: 3.717

9.  The rat model of femur fracture for bone and mineral research: An improved description of expected comminution, quantity of soft callus and incidence of complications.

Authors:  J-C Aurégan; R M Coyle; J R Danoff; R E Burky; Y Akelina; M P Rosenwasser
Journal:  Bone Joint Res       Date:  2013-08-08       Impact factor: 5.853

10.  Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis.

Authors:  Ashraf A Khanfour; Mohamed M El-Sayed
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-07-29
View more