Literature DB >> 18984339

Surface replacement arthroplasty of the proximal interphalangeal joint using the PIP-SRA implant: results, complications, and revisions.

Charles D Jennings1, Douglas P Livingstone.   

Abstract

PURPOSE: To evaluate the subjective and objective results of surface replacement arthroplasty (SRA) for arthritis of the proximal interphalangeal (PIP) joint using the PIP-SRA implant. Emphasis is placed on causes of complications, failures, and techniques used for revision.
METHODS: This is a retrospective review of 43 surface replacement PIP joint arthroplasties performed in 25 patients using the PIP-SRA implant. Subjective results were obtained through a mailed questionnaire. Pre- and postoperative ranges of motion were obtained for PIP joints and DIP joints. X-rays were evaluated for signs of subsidence, periprosthetic radiolucency, loosening, or stress-shielding. Joints requiring revision were separately analyzed.
RESULTS: The average follow-up time was 37 months (range, 12 to 72 months). The average active PIP joint arc of motion went from 57 degrees before surgery to 58 degrees after surgery, excluding 2 joints that were salvaged with arthrodesis. The average active DIP joint arc of motion went from 36 degrees before surgery to 24 degrees after surgery, excluding arthrodeses. Satisfaction rating revealed 26 very satisfactory (60%), 12 fairly satisfactory (28%), and 5 not satisfactory (12%). Thirty-three patients rated their joint pain better, 3 joints were unchanged, and 7 were worse. Eleven (26%) arthroplasties failed, requiring major revision (arthrodesis or replacement of 1 or both components) for pain. Ten of 11 revisions were due to loosening associated with the lack of cement. Revision procedures produced satisfactory results in 8 of 11 joints.
CONCLUSIONS: Surface replacement arthroplasty of the PIP joint holds promise for the future. It offers motion and stability for the index finger unattainable with silicone arthroplasty. Our results do not differ notably from those of other series using this implant, except that failures due to loosening in our study were almost exclusively associated with the lack of cement. Therefore, we recommend using cement with the PIP-SRA implant in every case until superior long-term results can be demonstrated using uncemented components. Proximal interphalangeal joint arthroplasty is an exacting procedure no matter what technique or implant is used, and no one technique has yet been proven superior to all others. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Entities:  

Mesh:

Year:  2008        PMID: 18984339     DOI: 10.1016/j.jhsa.2008.06.008

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  14 in total

Review 1.  Advances in Proximal Interphalangeal Joint Arthroplasty: Biomechanics and Biomaterials.

Authors:  Andy F Zhu; Paymon Rahgozar; Kevin C Chung
Journal:  Hand Clin       Date:  2018-05       Impact factor: 1.907

2.  Proximal Interphalangeal Joint Replacement with Surface Replacement Arthroplasty (SR-PIP): Functional Results and Complications.

Authors:  Christina Luther; Guenter Germann; Michael Sauerbier
Journal:  Hand (N Y)       Date:  2009-12-02

3.  Trends in Primary Proximal Interphalangeal Joint System and Revisions for Osteoarthritis of the Hand in the Medicare Database.

Authors:  Michael O Madden; Joseph R Palmer; Bijan J Ameri; Rushabh M Vakharia; Jacob Landes; Martin W Roche
Journal:  Hand (N Y)       Date:  2019-03-21

4.  Outcomes of Surface Replacement Proximal Interphalangeal Joint Arthroplasty Using the Self Locking Finger Joint Implant: Minimum Two Years Follow-up.

Authors:  Issei Komatsu; Yoshiya Arishima; Hirotomo Shibahashi; Toshihito Yamaguchi; Yoshitaka Minamikawa
Journal:  Hand (N Y)       Date:  2017-09-16

5.  Influence of index finger proximal interphalangeal joint arthrodesis on precision pinch kinematics.

Authors:  Mathieu Domalain; Peter J Evans; William H Seitz; Zong-Ming Li
Journal:  J Hand Surg Am       Date:  2011-11-03       Impact factor: 2.230

6.  Surface Replacement Proximal Interphalangeal Joint Arthroplasty: A Case Series.

Authors:  Pieter W Jordaan; Duncan McGuire; Michael W Solomons
Journal:  Hand (N Y)       Date:  2018-03-05

7.  Conical, radiographic, and patient-reported results of surface replacing proximal interphalangeal joint arthroplasty of the hand.

Authors:  Mohana Amirtharajah; Duretti Fufa; Nina Lightdale; Andew Weiland
Journal:  Iowa Orthop J       Date:  2011

8.  Prosthetic Arthroplasty of Proximal Interphalangeal Joints for Treatment of Osteoarthritis and Posttraumatic Arthritis: Systematic Review and Meta-Analysis Comparing the Three Ulnar Digits With the Index Finger.

Authors:  Michael T Milone; Christopher S Klifto; Jacques H Hacquebord
Journal:  Hand (N Y)       Date:  2018-08-02

9.  Reconstruction of swan neck deformities after proximal interphalangeal joint arthroplasty.

Authors:  John M Froelich; Marco Rizzo
Journal:  Hand (N Y)       Date:  2014-03

10.  Comparison of Volar and Dorsal Approach for PIP Arthroplasty.

Authors:  Geneva V Tranchida; Scott T Allen; Susan M Moen; Lauren O Erickson; Christina M Ward
Journal:  Hand (N Y)       Date:  2019-07-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.